Belden Store
23500D

Product Number: 23500D

ACIC 300V, 6 Pr #16 Str TC, XLPE Ins E1, IS/OS, PVC Jkt, AIA Armor, PVC Jkt, 90C Wet 105C Dry CSA HLABCD SUN RES -40C

Canadian Instrumentation Cable TC-ACIC 300V, 6 Pair 16AWG (7x24) Tinned Copper, XLPE Insulation E1 Color Code, Individual & Overall Beldfoil® Shield, PVC Inner Jacket, Aluminum Interlock Armor, PVC Outer Jacket, 90C Wet 105C Dry CSA HLABCD SUN RES -40C

Availability
Global
Status
Active
Orderable items
4

Ships from and sold by A5 IT.

Part numbers

23500D is a product family. Each item number below is a separate orderable part — colour, put-up and length differ.

Item #Putup TypeUPCOrder
23500D 0602500Reel612825322085Order online
23500D 0605000Reel612825322108Order online
23500D 060984Reel—Order online
23500D 0603280Reel—Order online

Specifications

Information

Put-Up TypeReel
Update and RevisionRevision Number: 0.363 Revision Date: 09-07-2025

Product Overview

Suitable ApplicationsIndustrial Control, Raceways Cable trays and ducts, Digital Control, Instruments (4-20ma, 0-10v, ...),low voltage digital control (24v, ...), encoders, control circuits, distributed control system (DCS),programmable logic controller (PLC), Solenoids, Valves, Actuators, Positioners

Construction Details

Overall Cable Diameter (Nominal)1.065 in

Conductor

ElementPair(s)
No. of Elements6
Size16 AWG
Stranding7x24
MaterialTC - Tinned Copper

Insulation

ElementPair(s)
MaterialXLP, XLPO, XLPE (Thermoset)
Nom. Thickness0.025 in (0.64 mm)
Nom. Insulation Diameter0.108 in (2.74 mm)
Color CodeBlack and White and Numbered

Inner Shield

ElementPair(s)
Shield TypeTape
MaterialBi-Laminate (Alum+Poly)
Coverage100%
Drainwire Type18 AWG (7x26) TC

Outer Shield

Shield TypeTape
MaterialBi-Laminate (Alum+Poly)
Coverage100%
Drainwire Type18 AWG (7x26) TC

Inner Jacket

MaterialPVC - Polyvinyl Chloride
Nom. Thickness0.063 in (1.6 mm)
Nom. Diameter0.736 in (18.7 mm)
ColorBlack

Armor

Armor Type & MaterialAIA - Aluminum Interlock Armor
Armor Thickness0.025 in
Diameter Over Armor0.961 in

Outer Jacket

MaterialPVC - Polyvinyl Chloride
Nom. Thickness0.052 in (1.3 mm)
Nom. Diameter1.065 in
RipcordYes

Electrical Characteristics

Nom Outer Shield DCR4.5 Ohm/1000ft (15 Ohm/km)

Electricals

Nom. Conductor DCR4.6 Ohm/1000ft
Nom. Inner Shield DCR5.4 Ohm/1000ft (18 Ohm/km)

Voltage

Voltage Rating300 V (CEC ACIC)

Mechanical Characteristics

Max. Pull Tension200 lbs (91 kg)
Bulk Cable Weight484 lbs/1000ft

Temperature

OperatingDry: -40°C to +105°C, Wet: -40°C to +90°C

Bend Radius

Stationary Min.12.72 in (323.1 mm)
Installation Min.12.72 in

Standards and Compliance

Environmental SuitabilityIndoor, Outdoor, Sunlight Resistance, UV Resistance
AWM ComplianceC22.2#239, Type ACIC, C22.2#174, HLABCD, C22.2#0.3, Clause 4.31
CEC / C(UL) ComplianceACIC, HLABCD, ACIC.
European Directive ComplianceEU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE)
APAC ComplianceChina RoHS II (GB/T 26572-2011)

History

Update and RevisionRevision Number: 0.363 Revision Date: 09-07-2025

Resources