Belden Store
7445WS

Product Number: 7445WS

MachFlexTM, 3+1G C #12 Str BC, PVC-NYL Ins, OA TC Brd, TPE Jkt, TPE Jkt, 1000V WTTC, 600V TC-ER

MachFlexTM for High Flex, 3+1G Conductor 12AWG (65x30) Bare Copper, PVC-NYL Insulation, Overall Tinned Copper Braid(85%) Shield, TPE Inner Jacket, TPE Outer Jacket, 1000V WTTC, 600V TC-ER

Availability
Global
Status
Active
Orderable items
3

Ships from and sold by A5 IT.

Part numbers

7445WS is a product family. Each item number below is a separate orderable part — colour, put-up and length differ.

Item #ColorPutup TypeLengthUPCFootnoteOrder
7445WS 060250ChromeReel250 ft612825186878COrder online
7445WS 0601000ChromeReel1,000 ft612825186861COrder online
7445WS 0605000ChromeReel5,000 ft612825186885COrder online

Specifications

Product Overview

Suitable ApplicationsRobotics, Robot, Continuous Flex

Construction Details

Overall Cable Diameter (Nominal)0.544 in

Conductor

ElementNo. of ElementsSizeStrandingMaterial
Conductor(s)312 AWG65x30BC - Bare Copper
Ground Wire112 AWG65x30BC - Bare Copper

Insulation

ElementMaterialNom. ThicknessNom. Insulation DiameterColor Code
Conductor(s)PVC/Nylon - Polyvinyl Chloride + Nylon0.021 in (0.53 mm)0.135 in (3.43 mm)Black and Numbered
Ground WirePVC/Nylon - Polyvinyl Chloride + Nylon0.021 in (0.53 mm)0.135 in (3.43 mm)Green/Yellow

Outer Shield

Shield TypeBraid
MaterialTinned Copper (TC)
Coverage85%

Inner Jacket

Separatornon-Woven Tape
MaterialTPE - Thermoplastic Elastomer
Nom. Thickness0.030 in (0.76 mm)
Nom. Diameter0.39 in (9.9 mm)
ColorChrome

Outer Jacket

MaterialTPE - Thermoplastic Elastomer
Nom. Thickness0.063 in (1.6 mm)
Nom. Diameter0.544 in

Electrical Characteristics

Nom Outer Shield DCR2.7 Ohm/1000ft (8.9 Ohm/km)

Electricals

ElementNom. Conductor DCRMax. Current
Conductor(s)1.8 Ohm/1000ft31 Amps per Conductor at 25oC
Ground Wire1.72 Ohm/1000ft (5.64 Ohm/km)

Voltage

UL Voltage Rating1000 V (WTTC), 600 V (TC-ER)

Mechanical Characteristics

Max. Pull Tension434 lbs (197 kg)
Bulk Cable Weight289 lbs/1000ft

Temperature

UL TemperatureUL : 90°C Dry, 75°C Wet; AWM 20328 : 105°C
Operating-40°C To +105°C

Bend Radius

Stationary Min.6.53 in (166 mm)
Installation Min.6.53 in

Standards and Compliance

Environmental SuitabilityOutdoor, Sunlight Resistance, UV Resistance, Oil Resistance
Flammability / Reaction to FireUL1685 UL Loading, IEEE 1202 FT4
NEC / UL ComplianceArticle 336
AWM ComplianceAWM 20328, AWM I/II A/B
CEC / C(UL) ComplianceCIC, TC.
European Directive ComplianceEU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE)
APAC ComplianceChina RoHS II (GB/T 26572-2011)

History

Update and RevisionRevision Number: 0.380 Revision Date: 09-07-2025
FootnoteC - CRATE REEL PUT-UP.