Belden Store
7435W

Product Number: 7435W

MachFlexTM, 2+1G C #14 Str BC, PVC-NYL Ins, TPE Jkt, 1000V WTTC, 600V TC-ER

MachFlexTM for High Flex, 2+1G Conductor 14AWG (41x30) Bare Copper, PVC-NYL Insulation, TPE Outer Jacket, 1000V WTTC, 600V TC-ER

Availability
Global
Status
Active
Orderable items
3

Ships from and sold by A5 IT.

Part numbers

7435W is a product family. Each item number below is a separate orderable part — colour, put-up and length differ.

Item #ColorPutup TypeLengthUPCFootnoteOrder
7435W 060250ChromeReel250 ft612825186564COrder online
7435W 0601000ChromeReel1,000 ft612825186557COrder online
7435W 0605000ChromeReel5,000 ft612825186571—Order online

Specifications

Product Overview

Suitable ApplicationsRobotics, Robot, Continuous Flex

Construction Details

Overall Cable Diameter (Nominal)0.329 in

Conductor

ElementNo. of ElementsSizeStrandingMaterial
Conductor(s)214 AWG41x30BC - Bare Copper
Ground Wire114 AWG41x30BC - Bare Copper

Insulation

ElementMaterialNom. ThicknessNom. Insulation DiameterColor Code
Conductor(s)PVC/Nylon - Polyvinyl Chloride + Nylon0.021 in (0.53 mm)0.117 in (2.97 mm)Black and Numbered, Green/Yellow
Ground WirePVC/Nylon - Polyvinyl Chloride + Nylon0.021 in (0.53 mm)0.117 in (2.97 mm)Green/Yellow

Outer Shield

MaterialNo Shield

Outer Jacket

Separatornon-Woven Tape
MaterialTPE - Thermoplastic Elastomer
Nom. Thickness0.047 in (1.2 mm)
Nom. Diameter0.329 in

Electrical Characteristics

Electricals

ElementNom. Conductor DCRMax. Current
Conductor(s)2.8 Ohm/1000ft26 Amps per Conductor at 25oC
Ground Wire2.73 Ohm/1000ft (8.96 Ohm/km)

Voltage

UL Voltage Rating1000 V (WTTC), 600 V (TC-ER)

Mechanical Characteristics

Max. Pull Tension160 lbs (73 kg)
Bulk Cable Weight79 lbs/1000ft

Temperature

UL TemperatureUL : 90°C Dry, 75°C Wet; AWM 20328 : 105°C
Operating-40°C To +105°C

Bend Radius

Stationary Min.1.32 in (33.5 mm)
Installation Min.1.65 in

Standards and Compliance

Environmental SuitabilityOutdoor, Sunlight Resistance, UV Resistance, Oil Resistance
Flammability / Reaction to FireUL1685 UL Loading, IEEE 1202 FT4
NEC / UL ComplianceArticle 336
AWM ComplianceAWM 20328, AWM I/II A/B
CEC / C(UL) ComplianceCIC, TC.
European Directive ComplianceEU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE)
APAC ComplianceChina RoHS II (GB/T 26572-2011)

History

Update and RevisionRevision Number: 0.376 Revision Date: 09-07-2025
FootnoteC - CRATE REEL PUT-UP.

Resources