Belden Store
7422W

Product Number: 7422W

MachFlexTM, 2+1G C #16 Str BC, PVC-NYL Ins, TPE Jkt, 1000V WTTC, 600V TC-ER

MachFlexTM for High Flex, 2+1G Conductor 16AWG (26x30) Bare Copper, PVC-NYL Insulation, TPE Outer Jacket, 1000V WTTC, 600V TC-ER

Availability
Global
Status
Active
Orderable items
3

Ships from and sold by A5 IT.

Part numbers

7422W is a product family. Each item number below is a separate orderable part — colour, put-up and length differ.

Item #ColorPutup TypeLengthUPCFootnoteOrder
7422W 060250ChromeReel250 ft612825186175COrder online
7422W 0601000ChromeReel1,000 ft612825186168COrder online
7422W 0605000ChromeReel5,000 ft612825186182—Order online

Specifications

Product Overview

Suitable ApplicationsRobotics, Robot, Continuous Flex

Construction Details

Overall Cable Diameter (Nominal)0.316 in

Conductor

ElementNo. of ElementsSizeStrandingMaterial
Conductor(s)216 AWG26x30BC - Bare Copper
Ground Wire116 AWG26x30BC - Bare Copper

Insulation

ElementMaterialNom. ThicknessNom. Insulation DiameterColor Code
Conductor(s)PVC/Nylon - Polyvinyl Chloride + Nylon0.021 in (0.53 mm)0.101 in (2.57 mm)Black and Numbered
Ground WirePVC/Nylon - Polyvinyl Chloride + Nylon0.021 in (0.53 mm)0.101 in (2.57 mm)Green/Yellow

Outer Shield

MaterialNo Shield

Outer Jacket

Separatornon-Woven Tape
MaterialTPE - Thermoplastic Elastomer
Nom. Thickness0.047 in (1.2 mm)
Nom. Diameter0.316 in

Electrical Characteristics

Electricals

ElementNom. Conductor DCRMax. Current
Conductor(s)4.18 Ohm/1000ft19 Amps per Conductor at 30oC
Ground Wire4.45 Ohm/1000ft (14.6 Ohm/km)30.4 Amps per Conductor at 30oC

Voltage

UL Voltage Rating1000 V (WTTC), 600 V (TC-ER)

Mechanical Characteristics

Max. Pull Tension120 lbs (54 kg)
Bulk Cable Weight65 lbs/1000ft

Temperature

UL TemperatureUL : 90°C Dry, 75°C Wet; AWM 20328 : 105°C
Operating-40°C To 105°C

Bend Radius

Stationary Min.1.26 in (32.0 mm)
Installation Min.1.58 in

Standards and Compliance

Environmental SuitabilityOutdoor, Sunlight Resistance, UV Resistance, Oil Resistance
Flammability / Reaction to FireUL1685 UL Loading, IEEE 1202 FT4
NEC / UL ComplianceArticle 336
AWM ComplianceAWM 20328, AWM I/II A/B
CEC / C(UL) ComplianceCIC, TC.
European Directive ComplianceEU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE)
APAC ComplianceChina RoHS II (GB/T 26572-2011)

History

Update and RevisionRevision Number: 0.365 Revision Date: 09-07-2025
FootnoteC - CRATE REEL PUT-UP.

Resources

Related flex cable