BELDEN Industrial Ethernet CAT6A cable, S/FTP, LSZH, Anti Rodent, Anti Termite, 4 Pair, AWG 23,Indoor
BELDEN Industrial Ethernet CAT6A, S/FTP, 4x2x 23AWG, Solid Bare Copper Conductors, Foam Polyolefin Insulation, Individually foil shielded pairs & Overall tinned copper braid shield, LSZH Jacket, Anti Rodent & Anti Termite cable.
- Availability
- Global
- Status
- Active
Specifications
Product Overview
| Suitable Applications | Ethernet: 10GBase-T, 100Base-TX, 1000Base-T |
|---|
Construction Details
| Overall Cable Diameter (Nominal) | 7.8 ± 0.3 mm |
|---|
Conductor
| Element | Pair(s) |
|---|---|
| Size | 23 AWG |
| Material | BC - Bare Copper |
Insulation
| Material | PO - Polyolefin (Foam) |
|---|---|
| Nom. Insulation Diameter | 1.35 mm (0.0531 in) |
| Color Code | 1. White & Blue, 2. Orange & White, 3. Green & White, 4. Brown & White |
Inner Shield
| Element | Pair(s) |
|---|---|
| Shield Type | Tapes (Each Pair) |
| Material | Bi-Laminate (Alum+Poly) |
Outer Shield
| Shield Type | Braid |
|---|---|
| Material | Tinned Copper (TC) |
| Coverage | 30% |
Outer Jacket
| Material | LSZH - Low Smoke Zero Halogen (Flame Retardant) |
|---|---|
| Ripcord | Yes |
Electrical Characteristics
| Electricals Table Notes | Nominal Velocity of Propagation: 0.77 |
|---|
Electricals
| Max. Conductor DCR | 95 Ω/km @ 20°C |
|---|---|
| Nom. Characteristic Impedance | 100 Ohm |
High Frequency
| Frequency | Max. Insertion Loss (Attenuation) [dB/100m] | Min. NEXT [dB] | Min. PSNEXT [dB] | Min. ACR [dB] | Min. PSACR [dB] | Min. ACRF (ELFEXT) [dB] | Min. PSACRF (PSELFEXT) [dB] | Min. RL (Return Loss) [dB] | Min. PSANEXT [dB] | Min. PSAACRF [dB] | Min. TCL [dB] | Min. ELTCTL [dB] | Min. Coupling Attenuation [dB] |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1 | 2.1 | 75.3 | 72.3 | 73.2 | 70.2 | 68 | 65 | 20 | 67 | 67 | 40 | 35 | |
| 4 MHz | 3.8 | 66.3 | 63.3 | 62.5 | 59.5 | 56 | 53 | 23 | 67 | 66.2 | 34 | 23 | |
| 10 MHz | 5.9 | 60.3 | 57.3 | 54.4 | 51.4 | 48 | 45 | 25 | 67 | 58.2 | 30 | 15 | |
| 16 MHz | 7.5 | 57.2 | 54.2 | 49.7 | 46.7 | 43.9 | 40.9 | 25 | 67 | 54.1 | 28 | 10.9 | |
| 31.3 MHz | 10.5 | 52.9 | 49.9 | 42.4 | 39.4 | 38.1 | 35.1 | 23.6 | 67 | 48.3 | 25.1 | 5.1 | 55 |
| 62.5 MHz | 15 | 48.4 | 45.4 | 33.4 | 30.4 | 32.1 | 29.1 | 21.5 | 65.6 | 42.3 | 22 | 55 | |
| 100 MHz | 19.1 | 45.3 | 42.3 | 26.2 | 23.2 | 28 | 25 | 20.1 | 62.5 | 38.2 | 20 | 55 | |
| 125 MHz | 21.5 | 43.8 | 40.8 | 22.3 | 19.3 | 26.1 | 23.1 | 19.4 | 61 | 36.3 | 19 | 53 | |
| 200 MHz | 27.6 | 40.8 | 37.8 | 13.2 | 10.2 | 22 | 19 | 18 | 58 | 32.2 | 17 | 49 | |
| 250 MHz | 31.1 | 39.3 | 36.3 | 8.2 | 5.2 | 20 | 17 | 17.3 | 56.5 | 30.2 | 16 | 47 | |
| 350 MHz | 37.3 | 37.1 | 34.1 | 17.1 | 14.1 | 17.3 | 54.3 | 27.3 | 44 | ||||
| 500 MHz | 45.3 | 34.8 | 31.8 | 14 | 11 | 17.3 | 52 | 24.2 | 41 |
Transfer Impedance
| Frequency | Max. Transfer Impedance |
|---|---|
| 1 | 50 |
| 10 | 100 |
| 30 | 200 |
| 100 | 1000 |
Voltage
| Voltage Rating | 72 V DC |
|---|---|
| Breakdown Voltage | 2500V DC/2Sec. |
Mechanical Characteristics
| Bulk Cable Weight | 67 kg/km (45 lbs/1000ft) |
|---|
Temperature
| Operating | -30°C to + 60°C |
|---|---|
| Storage | -20°C to + 50°C |
Bend Radius
| Installation Min. | 62.4 mm (2.46 in) |
|---|
Standards and Compliance
| Environmental Suitability | Indoor |
|---|---|
| Flammability / Reaction to Fire | IEC 60332-1-2, IEC 60332-3-22 |
| IEEE Compliance | IEEE 802.3bt Type 1, Type 2, Type 3, Type 4 |
| Data Category | Category 6A |
| TIA/EIA Compliance | ANSI/TIA 568.2-D |
| ISO/IEC Compliance | ISO/IEC 11801 Ed. 2.0:2002/A2:2010/C1:2011 IEC 61156-5 |
| European Halogen Free Standards | IEC 60754-1 - Halogen Amount = 0, IEC 60754-2 - Halogen Acid Gas Amount - Max. Conductivity = 10 μS/mm, IEC 60754-2 - Halogen Acid Gas Amount - Min. pH = 4.3 |
| European Directive Compliance | EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2) |
| APAC Compliance | China RoHS II (GB/T 26572-2011) |
History
| Update and Revision | Revision Number: 0.21 Revision Date: 02-26-2026 |
|---|
Resources
Related industrial ethernet cable
123076F
Fieldbus, 1 Pr #18 Str TC, PP ins, OS, PVC Jkt, AIA Armor, PVC Jkt, ISA/SP-50 Type A, PLTC, CM
1 · 18 AWG · TC - Tinned Copper · PP - Polypropylene
123083A
DeviceBus®, 2 Pr #15+18 Str TC, PVC+FPE Ins, IS+OA TC Brd, CPE Jkt, AIA Armor, PVC Jkt, CMG PLTC
PVC - Polyvinyl Chloride · 300 V (CMG, PLTC-ER)
123084A
DeviceBus®, 2 Pr #22+24 Str TC, PVC+FPE Ins, IS+OA TC Brd, PVC Jkt, AIA Armor, PVC Jkt, CM, CL2
PVC - Polyvinyl Chloride · 300 V (CM) · 75°C
127897A
DeviceBus®, 2 Pr #15+18 Str TC, PVC-NYL + FEP Ins, IS+OA TC Brd, PVC Jkt, AIA, PVC Jkt, 600V
PVC - Polyvinyl Chloride · 75°C Dry