Belden127922A
DataTuff® 5e, 4 Bonded-Pr #22 Sol BC, PO Ins, PVC Jkt, AIA Armor, PVC Jkt
Industrial Ethernet Cat 5e, 4 Bonded-Pair 22AWG (Solid) Bare Copper, PO Insulation, PVC Inner Jacket, Aluminum Interlock Armor, PVC Outer Jacket
- Availability
- Global
- Status
- Active
Specifications
Product Overview
| Suitable Applications | harsh environment, IIoT, factory or process automation, IP cameras and devices, data communication, etc. exposure to rodent, crush, or cut through force, power-limited tray, |
|---|
Physical Characteristics (Overall)
| Bonded-Pair Construction | Yes |
|---|
Conductor
| Element | Pair(s) |
|---|---|
| AWG | 22 |
| Stranding | Solid |
| Material | BC - Bare Copper |
| No. of Pairs | 4 |
Insulation
| Material | PO - Polyolefin |
|---|
Color Chart
| Color |
|---|
| White/Blue Stripe & Blue |
| White/Orange Stripe & Orange |
| White/Green Stripe & Green |
| White/Brown Stripe & Brown |
Inner Jacket
| Material | PVC - Polyvinyl Chloride |
|---|---|
| Nominal Diameter | 0.301 in |
| Ripcord | Yes |
Outer Jacket
| Material | PVC - Polyvinyl Chloride |
|---|---|
| Nominal Diameter | 0.620 in |
| Ripcord | No |
| Separator Material | Polyester Tape |
Construction and Dimensions
Armor
| Diameter over Armoring | 0.530 in |
|---|
Electrical Characteristics
Conductor DCR
| Max. Conductor DCR | 93.8 Ohm/km |
|---|
Capacitance
| Max. Capacitance Unbalance | 330 pF/100m |
|---|
Delay
| Max. Delay | 538 ns/100m |
|---|---|
| Max. Delay Skew | 45 ns/100m |
| Nominal Velocity of Propagation (VP) [%] | 70% |
High Frequency
| Frequency [MHz] | Max. Insertion Loss (Attenuation) | Min. NEXT [dB] | Min. PSNEXT [dB] | Min. ACR [dB] | Min. PSACR [dB] | Min. ACRF (ELFEXT) [dB] | Min. PSACRF (PSELFEXT) [dB] | Min. RL (Return Loss) [dB] | Max./Min. Input Impedance (unFitted) | Max./Min. Fitted Impedance |
|---|---|---|---|---|---|---|---|---|---|---|
| 1 MHz | 2.0 dB/100m | 65.3 dB | 65.3 dB | 63.3 dB | 60 dB | 63.8 dB | 60.8 dB | 20 dB | 100 ± 12 Ohm | 105 ± 10 Ohm |
| 4 MHz | 4.0 dB/100m | 56.3 dB | 56.3 dB | 52.3 dB | 52.3 dB | 51.7 dB | 48.7 dB | 23 dB | 100 ± 12 Ohm | 100 ± 10 Ohm |
| 8 MHz | 5.7 dB/100m | 51.8 dB | 51.8 dB | 46.1 dB | 46.1 dB | 45.7 dB | 42.7 dB | 24.5 dB | 100 ± 12 Ohm | 100 ± 10 Ohm |
| 10 MHz | 6.4 dB/100m | 50.3 dB | 50.3 dB | 43.9 dB | 43.9 dB | 43.8 dB | 40.8 dB | 25 dB | 100 ± 12 Ohm | 100 ± 10 Ohm |
| 16 MHz | 8.1 dB/100m | 47.3 dB | 47.3 dB | 39.1 dB | 39.1 dB | 39.7 dB | 36.7 dB | 25 dB | 100 ± 12 Ohm | 100 ± 10 Ohm |
| 20 MHz | 9.2 dB/100m | 45.8 dB | 45.8 dB | 35.2 dB | 35.2 dB | 37.7 dB | 34.7 dB | 25 dB | 100 ± 12 Ohm | 100 ± 10 Ohm |
| 25 MHz | 10.3 dB/100m | 44.3 dB | 44.3 dB | 34.1 dB | 34.1 dB | 35.8 dB | 32.8 dB | 24.3 dB | 100 ± 15 Ohm | 100 ± 10 Ohm |
| 31.25 MHz | 11.6 dB/100m | 42.9 dB | 42.9 dB | 31.3 dB | 31.3 dB | 33.9 dB | 30.9 dB | 23.6 dB | 100 ± 15 Ohm | 100 ± 10 Ohm |
| 62.5 MHz | 16.8 dB/100m | 38.4 dB | 38.4 dB | 21.6 dB | 21.6 dB | 27.8 dB | 24.8 dB | 21.5 dB | 100 ± 15 Ohm | 100 ± 10 Ohm |
| 100 MHz | 21.7 dB/100m | 35.3 dB | 35.3 dB | 17.1 dB | 17.1 dB | 23.8 dB | 20.8 dB | 20.1 dB | 100 ± 15 Ohm |
Voltage
| UL Description | CM |
|---|---|
| UL Voltage Rating | 300 V |
Temperature Range
| UL Temperature Rating | 75°C |
|---|---|
| Storage Temperature Range | -40°C to +85°C |
| Operating Temperature Range | -40°C To +75°C |
Mechanical Characteristics
| Bulk Cable Weight | 140 lbs/1000ft |
|---|---|
| Maximum Recommended Pulling Tension | 100 lbs |
Standards
| NEC Articles | Article 800 |
|---|---|
| NEC/(UL) Compliance | CM |
| CEC/C(UL) Compliance | CMG, HL |
| ISO/IEC Compliance | ISO/IEC 11801-1, IEC 61156-5 |
| CPR Euroclass | Eca |
| Data Category | Category 5e |
| TIA/EIA Compliance | ANSI/TIA-568.2-D Category 5e |
Applicable Environmental and Other Programs
| Environmental Space | Indoor/Outdoor |
|---|
Suitability
| Suitability - Aerial | No |
|---|---|
| Suitability - Burial | No |
| Suitability - Indoor | Yes |
| Suitability - Non-Halogenated | No |
| Suitability - Oil Resistance | Yes |
| Suitability - Outdoor | Yes |
| Suitability - Sunlight Resistance | Yes |
Flammability, LS0H, Toxicity Testing
| CSA/C(UL) Flammability | FT4 |
|---|---|
| UL Flammability | UL 1685 (UL Loading) |
Product Notes
| Notes | Operating temperatures are subject to length de-rating |
|---|
History
| Update and Revision | Revision Number: 0.37 Revision Date: 02-20-2026 |
|---|
Resources
Related industrial ethernet cable
Belden123076F
123076F
Fieldbus, 1 Pr #18 Str TC, PP ins, OS, PVC Jkt, AIA Armor, PVC Jkt, ISA/SP-50 Type A, PLTC, CM
1 · 18 AWG · TC - Tinned Copper · PP - Polypropylene
Belden123083A
123083A
DeviceBus®, 2 Pr #15+18 Str TC, PVC+FPE Ins, IS+OA TC Brd, CPE Jkt, AIA Armor, PVC Jkt, CMG PLTC
PVC - Polyvinyl Chloride · 300 V (CMG, PLTC-ER)
Belden123084A
123084A
DeviceBus®, 2 Pr #22+24 Str TC, PVC+FPE Ins, IS+OA TC Brd, PVC Jkt, AIA Armor, PVC Jkt, CM, CL2
PVC - Polyvinyl Chloride · 300 V (CM) · 75°C
Belden127897A
127897A
DeviceBus®, 2 Pr #15+18 Str TC, PVC-NYL + FEP Ins, IS+OA TC Brd, PVC Jkt, AIA, PVC Jkt, 600V
PVC - Polyvinyl Chloride · 75°C Dry