Belden Store
Belden127922A

Product Number: 127922A

DataTuff® 5e, 4 Bonded-Pr #22 Sol BC, PO Ins, PVC Jkt, AIA Armor, PVC Jkt

Industrial Ethernet Cat 5e, 4 Bonded-Pair 22AWG (Solid) Bare Copper, PO Insulation, PVC Inner Jacket, Aluminum Interlock Armor, PVC Outer Jacket

Availability
Global
Status
Active

Ships from and sold by A5 IT.

Specifications

Product Overview

Suitable Applicationsharsh environment, IIoT, factory or process automation, IP cameras and devices, data communication, etc. exposure to rodent, crush, or cut through force, power-limited tray,

Physical Characteristics (Overall)

Bonded-Pair ConstructionYes

Conductor

ElementPair(s)
AWG22
StrandingSolid
MaterialBC - Bare Copper
No. of Pairs4

Insulation

MaterialPO - Polyolefin

Color Chart

Color
White/Blue Stripe & Blue
White/Orange Stripe & Orange
White/Green Stripe & Green
White/Brown Stripe & Brown

Inner Jacket

MaterialPVC - Polyvinyl Chloride
Nominal Diameter0.301 in
RipcordYes

Outer Jacket

MaterialPVC - Polyvinyl Chloride
Nominal Diameter0.620 in
RipcordNo
Separator MaterialPolyester Tape

Construction and Dimensions

Armor

Diameter over Armoring0.530 in

Electrical Characteristics

Conductor DCR

Max. Conductor DCR93.8 Ohm/km

Capacitance

Max. Capacitance Unbalance330 pF/100m

Delay

Max. Delay538 ns/100m
Max. Delay Skew45 ns/100m
Nominal Velocity of Propagation (VP) [%]70%

High Frequency

Frequency [MHz]Max. Insertion Loss (Attenuation)Min. NEXT [dB]Min. PSNEXT [dB]Min. ACR [dB]Min. PSACR [dB]Min. ACRF (ELFEXT) [dB]Min. PSACRF (PSELFEXT) [dB]Min. RL (Return Loss) [dB]Max./Min. Input Impedance (unFitted)Max./Min. Fitted Impedance
1 MHz2.0 dB/100m65.3 dB65.3 dB63.3 dB60 dB63.8 dB60.8 dB20 dB100 ± 12 Ohm105 ± 10 Ohm
4 MHz4.0 dB/100m56.3 dB56.3 dB52.3 dB52.3 dB51.7 dB48.7 dB23 dB100 ± 12 Ohm100 ± 10 Ohm
8 MHz5.7 dB/100m51.8 dB51.8 dB46.1 dB46.1 dB45.7 dB42.7 dB24.5 dB100 ± 12 Ohm100 ± 10 Ohm
10 MHz6.4 dB/100m50.3 dB50.3 dB43.9 dB43.9 dB43.8 dB40.8 dB25 dB100 ± 12 Ohm100 ± 10 Ohm
16 MHz8.1 dB/100m47.3 dB47.3 dB39.1 dB39.1 dB39.7 dB36.7 dB25 dB100 ± 12 Ohm100 ± 10 Ohm
20 MHz9.2 dB/100m45.8 dB45.8 dB35.2 dB35.2 dB37.7 dB34.7 dB25 dB100 ± 12 Ohm100 ± 10 Ohm
25 MHz10.3 dB/100m44.3 dB44.3 dB34.1 dB34.1 dB35.8 dB32.8 dB24.3 dB100 ± 15 Ohm100 ± 10 Ohm
31.25 MHz11.6 dB/100m42.9 dB42.9 dB31.3 dB31.3 dB33.9 dB30.9 dB23.6 dB100 ± 15 Ohm100 ± 10 Ohm
62.5 MHz16.8 dB/100m38.4 dB38.4 dB21.6 dB21.6 dB27.8 dB24.8 dB21.5 dB100 ± 15 Ohm100 ± 10 Ohm
100 MHz21.7 dB/100m35.3 dB35.3 dB17.1 dB17.1 dB23.8 dB20.8 dB20.1 dB100 ± 15 Ohm

Voltage

UL DescriptionCM
UL Voltage Rating300 V

Temperature Range

UL Temperature Rating75°C
Storage Temperature Range-40°C to +85°C
Operating Temperature Range-40°C To +75°C

Mechanical Characteristics

Bulk Cable Weight140 lbs/1000ft
Maximum Recommended Pulling Tension100 lbs

Standards

NEC ArticlesArticle 800
NEC/(UL) ComplianceCM
CEC/C(UL) ComplianceCMG, HL
ISO/IEC ComplianceISO/IEC 11801-1, IEC 61156-5
CPR EuroclassEca
Data CategoryCategory 5e
TIA/EIA ComplianceANSI/TIA-568.2-D Category 5e

Applicable Environmental and Other Programs

Environmental SpaceIndoor/Outdoor

Suitability

Suitability - AerialNo
Suitability - BurialNo
Suitability - IndoorYes
Suitability - Non-HalogenatedNo
Suitability - Oil ResistanceYes
Suitability - OutdoorYes
Suitability - Sunlight ResistanceYes

Flammability, LS0H, Toxicity Testing

CSA/C(UL) FlammabilityFT4
UL FlammabilityUL 1685 (UL Loading)

Product Notes

NotesOperating temperatures are subject to length de-rating

History

Update and RevisionRevision Number: 0.37 Revision Date: 02-20-2026

Resources

Related industrial ethernet cable