Belden Store
ATMM25

Product Number: ATMM25

CAT3 Backbone, 25pr, Armor Shield, PVC Jkt, CMR

CAT3, ATMM/ARMM, 25-Pair, F/UTP-foil shield , Riser-CMR, Premise Backbone Cable, 24 AWG solid bare copper conductors, foam polyolefin insulation with PVC skin, ripcord, corrugated aluminum shield bonded to overall PVC jacket

Availability
Global
Status
Discontinued
Orderable items
2

Ships from and sold by A5 IT.

Part numbers

ATMM25 is a product family. Each item number below is a separate orderable part — colour, put-up and length differ.

Item #ColorPutup TypeUPCOrder
ATMM25 008CUTGrayCut to Length612825061984Order online
ATMM25 008CUTGrayCut to Length612825061984Order online

Specifications

Product Overview

Suitable ApplicationsPremise Backbone Cable

Product Life Cycle

Life CycleDiscontinued - the product is no longer manufactured
Discontinuation Announcement Date2022-08-08

Construction Details

Conductor

Size24
StrandingSolid
MaterialBC - Bare Copper
No. of Pairs25

Insulation

MaterialColor Code
PO - Polyolefin (Foam)White & Blue, White & Orange, White & Green, White & Brown, White & Slate, Red & Blue, Red & Orange, Red & Green, Red & Brown, Red & Slate, Black & Blue, Black & Orange, Black & Green, Black & Brown, Black & Slate, Yellow & Blue, Yellow & Orange, Yellow & Green, Yellow & Brown, Yellow & Slate, Violet & Blue, Violet & Orange, Violet & Green, Violet & Brown, Violet & Slate
Blue/White

Outer Shield

MaterialAluminum

Armor

Armor Type & MaterialCAT - Corrugated Aluminum Tape
Armor Thickness.008 in (0.20 mm)

Outer Jacket

MaterialPVC - Polyvinyl Chloride
Nom. Diameter0.470 in
RipcordYes

Electrical Characteristics

Electricals

Max. Conductor DCR93.8 Ohm/km (28.6 Ohm/1000ft)
Max. Capacitance Unbalance330 pF/100m

Delay

Frequency16 MHz
Max. Delay543 ns/100m
Max. Delay Skew45 ns/100m
Nom. Velocity of Prop.68%

High Frequency

Frequency [MHz]Max. Insertion Loss (Attenuation) [dB/100m]Min. NEXT [dB]Min. PSNEXT [dB]Min. ACR [dB]Min. PSACR [dB]Min. RL (Return Loss) [dB]Max./Min. Fitted Impedance
0.7722.247.043.050.146.1100 +/- 15
1.02.645.041.047.843.812.0100 +/- 15
4.05.636.032.036.032.012.0100 +/- 15
8.08.531.027.028.324.312.0100 +/- 15
10.09.730.026.026.222.212.0100 +/- 15
16.013.127.023.020.116.110.0100 +/- 15

Voltage

UL Voltage Rating300 V RMS

Mechanical Characteristics

Max. Pull Tension150 lbs (68 kg)
Bulk Cable Weight134 lbs/1000ft (199 kg/km)

Temperature

UL Temperature60°C
Operating-30°C To +60°C
Installation-20°C To +60°C
Storage-30°C To +60°C

Bend Radius

Stationary Min.4.75 in (121 mm)
Installation Min.9.5 in (240 mm)

Standards and Compliance

Environmental SuitabilityRiser, Indoor
Flammability / Reaction to FireUL 1666 Riser, FT4
CPR ComplianceCPR Euroclass: Eca
NEC / UL ComplianceCMR
CEC / C(UL) ComplianceCMR.
Data CategoryCategory 3
TIA/EIA ComplianceANSI/TIA-568-C.2 Category 3
European Directive ComplianceEU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE), REACH: 2017-07-10
UK Regulation ComplianceUKCA Mark
APAC ComplianceChina RoHS II (GB/T 26572-2011)

Product Notes

NotesElectrical values are expected performance based on cable testing and representative performance within a typical Belden system. Print Includes Descending Footage/Meter Markings. Corrugated Aluminum Armor Bonded to the Jacket.

History

Update and RevisionRevision Number: 0.428 Revision Date: 07-30-2026

Resources

Related category 3 cable