RS485, 1P 22AWG Str TC, XLPE Ins, OS+TC Brd, LSZH Inner Jkt, SWA, LSZH Outer Jkt, ABS Approved

RS-485, 1PR x 22AWG Stranded Tinned Copper, Foamed Electron-Beam Cross Linked Polyethylene Insulation, Overall Foil Plus Tinned Copper Braid Shield, Low Smoke Zero Halogen Inner Jacket, Steel Wire Armor, Low Smoke Zero Halogen Outer Jacket, ABS Approved

Availability
Global
Status
Active
Orderable items
13

Ships from and sold by A5 IT.

Part numbers

50091LS is a product family. Each item number below is a separate orderable part — colour, put-up and length differ.

Item #ColorPutup TypeLengthEANOrder
50091LS-A305BlackReel305 m8719605220196Order online
50091LS-A476BlackReel476 m8719605220202Order online
50091LS 010500MBlackReel500 m—Order online
50091LS-A500BlackReel500 m8719605220219Order online
50091LS-A692BlackReel692 m8719605220226Order online
50091LS-A724BlackReel724 m8719605220233Order online
50091LS 0101000MBlackReel1,000 m—Order online
50091LS 060500MChromeReel500 m—Order online
50091LS 0601000MChromeReel1,000 m—Order online
50091LS-A100GRAYReel100 m8719605220189Order online
50091LS-J810GRAYReel810 m8719605220158Order online
50091LS-J830GRAYReel830 m8719605220165Order online
50091LS-J850GRAYReel850 m8719605220172Order online

Specifications

Product Overview

Suitable ApplicationsDesigned for applications which are used for RS 232/422/485, CANBUS, MODBUS communication protocols. Cable applications include motion oriented machine, machine control networks, temperature controllers, control panels, machine cutting tools, auxiliary equipment, SCADA communications, etc. These cables are used in emergency evacuation / shutdown systems in building automation, offshore, oil & gas and railway applications and are flame retardant according to IEC 60332-3-22 Category A

Construction Details

Overall Cable Diameter (Nominal)10.0 mm (0.394 in)

Conductor

Size22 AWG
StrandingStranded
MaterialTC - Tinned Copper

Insulation

MaterialEB-XLFMPE
Color CodeWhite & Blue

Outer Shield

Shield TypeMaterialDrainwire Type
TapeBi-Laminate (Alum+Poly)
BraidTinned Copper (TC)24 AWG (7x32) TC

Inner Jacket

MaterialLSZH - Low Smoke Zero Halogen (Flame Retardant)

Armor

Armor Type & MaterialSWA - Steel Wire Armor

Outer Jacket

MaterialLSZH - Low Smoke Zero Halogen (Flame Retardant)

Electrical Characteristics

High Frequency Table (Nominal/Typical) NotesNom. Inductance to Resistance ratio (L/R): 25 μH/Ω

Electricals

Nom. Conductor DCR59.4 Ohm/km (18.1 Ohm/1000ft)
Nom. Capacitance Cond-to-Cond46 pF/m (14 pF/ft)
Nom. Capacitance Cond-to-Shield82 pF/m (25 pF/ft)
Nom. Characteristic Impedence120 Ohm
Nom. Delay5.2 ns/m
Nom. Inductance1 μH/m (0.30 μH/ft)
Min. Insulation Resistance1,000
Max. Current2.1 Amps per conductor at 25°C

Voltage

Voltage Rating300 V
Breakdown Voltage1.5 kVac / 2s

Mechanical Characteristics

Bulk Cable Weight203.6 kg/km (136.8 lbs/1000ft)

Temperature

Operating-40°C To +90°C

Standards and Compliance

Environmental SuitabilitySunlight Resistance, UV Resistance, Oil Resistance, Oil Resistance
Flammability / Reaction to FireIEC 60332-1-2, IEC 60332-3-22
Marine ComplianceABS Type Approval Certificate 20-2029059-PDA
ISO/IEC ComplianceIEC 60092-376
European Halogen Free StandardsIEC 60754-1 - Halogen Amount = Max 0.5%, IEC 60754-2 - Halogen Acid Gas Amount - Max. Conductivity = 10 μS/mm, IEC 60754-2 - Halogen Acid Gas Amount - Min. pH = 4.3
European Directive ComplianceEU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), REACH, EU Directive 2011/65/EU (RoHS 2)
APAC ComplianceChina RoHS II (GB/T 26572-2011)
Other Standard Compliance(s)Toxicity Index < 5 as per EN 50305 / NF F63-305 (ITC)

Product Notes

NotesSmoke Density ASTM D2843 Max. 40%