Belden Store
2106A

Product Number: 2106A

Fieldbus, 20 Pr #18 Str TC, XLPO Ins, IS/OS, TPE Jkt, CMG

Fieldbus, 20 Pair 18AWG (7x26) Tinned Copper, XLPO Insulation, Individual & Overall Beldfoil® Shield, TPE Outer Jacket, CMG

Availability
Global
Status
Active
Orderable items
4

Ships from and sold by A5 IT.

Part numbers

2106A is a product family. Each item number below is a separate orderable part — colour, put-up and length differ.

Item #ColorPut-Up TypeLengthUPCOrder
2106A 0061000Blue, LightReel1,000 ft612825129066Order online
2106A 0065000Blue, LightReel5,000 ft612825129073Order online
2106A 0031000OrangeReel1,000 ft612825129042Order online
2106A 0035000OrangeReel5,000 ft612825129059Order online

Specifications

Product Overview

Suitable Applicationsharsh environment digital and serial two-way communication, oil and gas extraction and refining sites, petrochemical, Profibus process automation or Foundation FieldBus process automation, extreme temperature environments, exposure to humidity/moisture, dust, and oil, remote locations long distance applications, etc.

Physical Characteristics (Overall)

Conductor Count40

Conductor

ElementPair(s)
AWG18
Stranding7x26
MaterialTC - Tinned Copper

Insulation

MaterialXLPE - Cross-Linked Polyethylene (Thermoset)
Nominal Wall Thickness0.032 in

Color Chart

NumberColor
1Blue, Orange and Numbered
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20

Inner Shield

TypeTape
MaterialBi-Laminate (Alum+Poly)
Material Trade NameBeldfoil®
Coverage [%]100%
Drainwire MaterialTC - Tinned Copper
Drainwire AWG20
Drainwire Construction n x D7x28

Outer Shield

TypeTape
MaterialBi-Laminate (Alum+Poly)
Material Trade NameBeldfoil®
Coverage [%]100%
Drainwire MaterialTC - Tinned Copper
Drainwire AWG18
Drainwire Construction n x D7x26

Outer Jacket

MaterialTPE - Thermoplastic Elastomer
Nominal Diameter1.249 in
Nominal Wall Thickness0.085 in
RipcordYes

Electrical Characteristics

Electrical Characteristics NotesMax Propagation Delay Change From 7.812 kHz to 39.06 kHz: 518 pS/ft
Other Electrical Characteristic 231.25 KBits/sec

Conductor DCR

Nominal Conductor DCR5.86 Ohm/1000ft

Capacitance

Max. Capacitance Unbalance1.2 pF/ft
Nom. Capacitance Conductor to Conductor22 pF/ft

Inductance

Nominal Inductance0.22 μH/ft

Impedance

Nominal Characteristic Impedance120 Ohm

High Frequency (Nominal/Typical)

Nom. Insertion Loss0.08 dB/100ft

Delay

Nominal Velocity of Propagation (VP) [%]64%

High Frequency

Max. Insertion Loss (Attenuation)0.091 dB/100ft
Max./Min. Input Impedance (unFitted)100 Ohm

Current

ElementPer Conductor
Max. Recommended Current [A]5.4 Amps per Conductor

Voltage

DescriptionCSA CIC type TC
UL Voltage Rating300 V

Temperature Range

Installation Temp Rating-25°C
UL Temperature Rating90°C
Operating Temperature Range-40°C to 90°C

Mechanical Characteristics

Oil ResistanceYes
Bulk Cable Weight734 lbs/1000ft
Maximum Recommended Pulling Tension1170 lbs
Minimum Minor Axis Bend Radius12.5 in

Standards

NEC ArticlesArticle 725, Article 727, Article 800
NEC/(UL) ComplianceCMG, ITC, PLTC
CEC/C(UL) ComplianceCIC, TC
CSA AWM ComplianceAWM I A/B II A/B
ISO/IEC ComplianceIEC 61158-2
Other StandardsISA/SP-50 Type A

Applicable Environmental and Other Programs

EU Directive 2000/53/EC (ELV)Yes
EU Directive 2003/11/EC (BFR)Yes
EU Directive 2011/65/EU (RoHS 2)Yes
EU Directive 2012/19/EU (WEEE)Yes
EU Directive 2015/863/EU (RoHS 2 amendment)Yes
EU Directive ComplianceEU Directive 2003/11/EC (BFR)
EU CE MarkYes
MII Order #39 (China RoHS)Yes

Suitability

Suitability - BurialYes
Suitability - IndoorYes
Suitability - Oil ResistanceYes
Suitability - OutdoorYes
Suitability - Sunlight ResistanceYes

Flammability, LS0H, Toxicity Testing

UL FlammabilityUL1685 UL Loading
IEC FlammabilityIEC 60332-3-24
UL voltage rating300 V RMS

Plenum/Non-Plenum

Plenum (Y/N)No

History

Update and RevisionRevision Number: 0.517 Revision Date: 06-10-2026

Resources

Related multi-pair cable