Belden Store
Belden133084A

Product Number: 133084A

DeviceBus®, 2 Pr #22+24 Str TC, PVC+FPE Ins, IS+OA TC Brd, PVC Jkt, SIA Armor, PVC Jkt, CM, CL2

DeviceBus® for ODVA DeviceNetTM, 2 Pair 22+24AWG (19x34+19x36) Tinned Copper, PVC+Foam PE Insulation, Individual Beldfoil® & OA Tinned Copper Braid(65%) Shield, PVC Inner Jacket, Steel Interlock Armor, PVC Outer Jacket, CM, CL2

Availability
Global
Status
Active

Ships from and sold by A5 IT.

Specifications

Product Overview

Suitable Applicationsexposure to rodent, crush, or cut through force, harsh environment, ODVA device-level communication, used with CIP (common Industrial Protocol) for control, configuration, and data collection between devices, such as sensors and actuators, and higher level devices such as PLC, and PC in industrial automation, bus topology, etc.

Construction Details

Overall Cable Diameter (Nominal)0.573 in (14.6 mm)

Conductor

ElementNo. of ElementsSizeStrandingMaterial
Power Pair(s)122 AWG19x34TC - Tinned Copper
Data Pair(s)124 AWG19x36TC - Tinned Copper

Insulation

ElementMaterialNom. ThicknessColor Code
Power Pair(s)PVC - Polyvinyl Chloride0.021 in (0.53 mm)Red & Black
Data Pair(s)PE - Polyethylene (Foam)0.026 in (0.66 mm)Blue & White

Inner Shield

ElementShield TypeMaterialCoverage
Power Pair(s)TapeBi-Laminate (Alum+Poly)100%
Data Pair(s)TapeBi-Laminate (Alum+Poly)100%

Outer Shield

Shield TypeBraid
MaterialTinned Copper (TC)
Coverage65%
Drainwire Type22 AWG (19x34) TC

Inner Jacket

MaterialPVC - Polyvinyl Chloride
Nom. Thickness0.032 in (0.81 mm)
Nom. Diameter0.280 in (7.11 mm)

Armor

Armor Type & MaterialSIA - Steel Interlock Armor

Outer Jacket

MaterialPVC - Polyvinyl Chloride
Nom. Thickness0.045 in (1.1 mm)
Nom. Diameter0.573 in (14.6 mm)

Electrical Characteristics

Nom Outer Shield DCR3.2 Ohm/1000ft (10 Ohm/km)

Electricals

ElementNom. Conductor DCRNom. Capacitance Cond-to-CondNom. Characteristic ImpedenceNom. Velocity of Prop.Max. Current
Power Pair(s)17.5 Ohm/1000ft (57.4 Ohm/km)4 Amps per Conductor at 25oC (Power Pair)
Data Pair(s)28.0 Ohm/1000ft (91.9 Ohm/km)12 pF/ft (39 pF/m)120 Ohm75%4 Amps Per Conductor at 24 V (per NEC CL2) (Power Pair)

High Frequency

ElementFrequency [MHz]
Data Pair(s)0.125
0.5
1

Voltage

UL Voltage Rating300 V (CM)

Mechanical Characteristics

Max. Pull Tension65 lbs (29 kg)
Bulk Cable Weight155 lbs/1000ft (231 kg/km)

Temperature

UL Temperature75°C
Operating-20°C to +60°C

Standards and Compliance

Environmental SuitabilityIndoor, Outdoor, Sunlight Resistance, Oil Resistance
Flammability / Reaction to FireUL1685 FT4 Loading
NEC / UL ComplianceArticle 725, Article 800, CL2, CM
AWM ComplianceAWM 20201, HLBCD
CEC / C(UL) ComplianceCMG HLBCD.
European Directive ComplianceEU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE)
APAC ComplianceChina RoHS II (GB/T 26572-2011)
Other Standard Compliance(s)ODVA Class 2 Thin

Product Notes

NotesFlex Life: +/- 90 Degree Flex Test, 2" Diameter, 2 lbs. tension: 2000 Cycles minimum. Meter marks on jacket to aid users in installation. ODVA DeviceNet is an Open DeviceNet Vendor Association, Inc. trademark.

History

Update and RevisionRevision Number: 0.90 Revision Date: 12-22-2023

Resources