Belden Store
9L28050

Product Number: 9L28050

Flat Gray Ribbon Cable .050" Pitch, 9L280XX Series, #28-50c, PVC Ins

Flat Gray Ribbon Cable .050" Pitch, 9L280XX Series, 50 Conductor, 28 AWG (7x36) Tinned Copper, PVC Insulation

Availability
Global
Status
Active
Orderable items
1

Ships from and sold by A5 IT.

Part numbers

9L28050 is a product family. Each item number below is a separate orderable part — colour, put-up and length differ.

Item #ColorLengthUPCOrder
9L28050 008H100Gray100 ft612825221708Order online

Specifications

Product Overview

Suitable ApplicationsInternal interconnection, internal wiring of electronic equipment, reliable mass-termination to standard IDC connectors

Construction Details

Conductor Spacing Center-Center.050 +/- .002 in
Conductor Spacing Center-Center Outside2.450 +/- .011 in

Conductor

ElementConductor(s)
No. of Elements50
Size28 AWG
Stranding7x36
MaterialTC - Tinned Copper

Insulation

ElementConductor(s)
MaterialPVC - Polyvinyl Chloride
Nom. Thickness0.010 in (0.25 mm)
Nom. Insulation Diameter0.035 in (0.89 mm)
Color CodeGray
NotesA Red Stripe over the first conductor

Electrical Characteristics

High Frequency Table (Nominal/Typical) NotesGS=Ground-Signal Mode; GSG=Ground-Signal-Ground Mode

Electricals

Nom. Conductor DCRNom. Capacitance Cond-to-CondNom. Characteristic ImpedenceNom. DelayNom. InductanceNom. Velocity of Prop.Max. Current
68.2 Ohm/1000ft18 pF/ft (59 pF/m)150 Ohm1.4 ns/ft0.29 μH/ft (0.95 μH/m)72%1 Amp per Conductor at 20oC
10 pF/ft (33 pF/m)105 Ohm0.2 μH/ft (0.66 μH/m)
15 pF/ft (49 pF/m)

Unbalanced Crosstalk

ElementTypical Unbalanced NEXT %Typical Unbalanced FEXT %Typical Cross Talk Pulse Rise Time
10 ft. sample length4.873 ns
10 ft. sample length3.54.75 ns
10 ft. sample length337 ns

High Frequency (Nominal/Typical)

Frequency [MHz]Nom. Insertion Loss (Attenuation)
102.8 dB/100ft
204.8 dB/100ft
306.5 dB/100ft
408.3 dB/100ft
509.8 dB/100ft
6012 dB/100ft
7013 dB/100ft
8014 dB/100ft
9015.8 dB/100ft
10017 dB/100ft

Voltage

UL Voltage Rating300 V

Mechanical Characteristics

Bulk Cable Weight65 lbs/1000ft

Temperature

UL Temperature105°C
Operating-40°C to +105°C

Bend Radius

Installation Min.0.5 in (13 mm)

Standards and Compliance

Environmental SuitabilityIndoor
Flammability / Reaction to FireVW-1
AWM ComplianceAWM 2651, AWM 1/11, A
European Directive ComplianceEU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE)
APAC ComplianceChina RoHS II (GB/T 26572-2011)

History

Update and RevisionRevision Number: 0.501 Revision Date: 09-07-2025

Resources

Related flat ribbon cable