Belden Store
C5701

Product Number: C5701

Teck90 1000V, 3+G C #14+14 Str BC, XLPE Ins M4, PVC Jkt, AIA Armor, Blk PVC Jkt, CSA HL SUN RES -40C

Teck90 1000V, 3+G Conductor 14+14AWG (7x22H) Bare Copper, XLPE Insulation M4 Color Code, PVC Inner Jacket, Aluminum Interlock Armor, Black PVC Outer Jacket, CSA HL SUN RES -40C

Availability
Global
Status
Active
Orderable items
4

Ships from and sold by A5 IT.

Part numbers

C5701 is a product family. Each item number below is a separate orderable part — colour, put-up and length differ.

Item #Putup TypeUPCOrder
C5701 01010000Reel612825284147Order online
C5701 0102500Reel612825284154Order online
C5701 0105000Reel612825284161Order online
C5701 0105000Reel612825284161Order online

Specifications

Information

Put-Up TypeReel
Update and RevisionRevision Number: 0.239 Revision Date: 02-20-2026

Product Overview

Suitable ApplicationsPower and Control Applications up to 600V

Construction Details

Overall Cable Diameter (Nominal)0.763 in

Conductor

ElementNo. of ElementsSizeStrandingMaterial
Conductor(s)314 AWG7x23BC - Bare Copper
Ground Wire114 AWG7x22BC - Bare Copper

Insulation

ElementMaterialNom. ThicknessNom. Insulation DiameterColor Code
Conductor(s)XLP, XLPO, XLPE (Thermoset)0.045 in (1.1 mm)0.162 in mmRed, Black, Blue
Ground WireNo Insulation

Outer Shield

MaterialNo Shield

Inner Jacket

MaterialPVC - Polyvinyl Chloride
Nom. Thickness0.047 in (1.2 mm)
Nom. Diameter0.442 in (11.2 mm)

Armor

Armor Type & MaterialAIA - Aluminum Interlock Armor
Diameter Over Armor0.667 in

Outer Jacket

MaterialPVC - Polyvinyl Chloride
Nom. Thickness0.048 in (1.2 mm)
Nom. Diameter0.763 in
RipcordYes

Electrical Characteristics

Electricals

ElementNom. Conductor DCRMax. Current
Conductor(s)2.67 Ohm/1000ft24 Amps per Conductor at 30oC
Ground Wire2.67 Ohm/1000ft (8.76 Ohm/km)

Voltage

Voltage Rating1000 V (TECK 90)

Mechanical Characteristics

Max. Pull Tension200 lbs (91 kg)
Bulk Cable Weight231 lbs/1000ft

Temperature

Operating-40°C To +90°C
Installation-25°C To +90°C

Bend Radius

Stationary Min.6.10 in (155 mm)
Installation Min.6.10 in

Standards and Compliance

Environmental SuitabilityIndoor, Outdoor, Sunlight Resistance, Burial
CEC / C(UL) ComplianceTECK 90, HL.
European Directive ComplianceEU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE)
APAC ComplianceChina RoHS II (GB/T 26572-2011)

History