Teck90 1000V, 2+G C #6+8 Str BC, XLPE Ins M4, PVC Jkt, AIA Armor, Blk PVC Jkt, CSA HL SUN RES -40C
Teck90 1000V, 2+G Conductor 6+8AWG (7x14H) Bare Copper, XLPE Insulation M4 Color Code, PVC Inner Jacket, Aluminum Interlock Armor, Black PVC Outer Jacket, CSA HL SUN RES -40C
- Availability
- Global
- Status
- Active
- Orderable items
- 8
Part numbers
C5590 is a product family. Each item number below is a separate orderable part — colour, put-up and length differ.
| Item # | Putup Type | UPC | Order |
|---|---|---|---|
| C5590 0101640 | Reel | 612825283669 | Order online |
| C5590 0102952 | Reel | — | Order online |
| C5590 0103280 | Reel | — | Order online |
| C5590 0105000 | Reel | — | Order online |
| C5590 0105250 | Reel | — | Order online |
| C5590 0107500 | Reel | — | Order online |
| C5590 010984 | Reel | — | Order online |
| C5590 0104920 | Reel | — | Order online |
Specifications
Product Overview
| Suitable Applications | CEC Power and Control Applications up to 600V |
|---|
Construction Details
| Overall Cable Diameter (Nominal) | 1.047 in (26.59 mm) |
|---|
Conductor
| Element | No. of Elements | Size | Stranding | Material |
|---|---|---|---|---|
| Conductor(s) | 2 | 6 AWG | 7x15 | BC - Bare Copper |
| Ground Wire | 1 | 8 AWG | 7x16 | BC - Bare Copper |
Insulation
| Element | Material | Nom. Thickness | Nom. Insulation Diameter | Color Code |
|---|---|---|---|---|
| Conductor(s) | XLP, XLPO, XLPE (Thermoset) | 0.060 in (1.5 mm) | 0.300 in mm | Black, White |
| Ground Wire | No Insulation |
Outer Shield
| Material | No Shield |
|---|
Inner Jacket
| Material | PVC - Polyvinyl Chloride |
|---|---|
| Nom. Thickness | 0.063 in (1.6 mm) |
| Nom. Diameter | 0.726 in (18.4 mm) |
Armor
| Armor Type & Material | AIA - Aluminum Interlock Armor |
|---|---|
| Diameter Over Armor | 0.951 in (24.2 mm) |
Outer Jacket
| Material | PVC - Polyvinyl Chloride |
|---|---|
| Nom. Thickness | 0.048 in (1.2 mm) |
| Nom. Diameter | 1.047 in (26.59 mm) |
| Ripcord | Yes |
Electrical Characteristics
Electricals
| Element | Nom. Conductor DCR | Max. Current |
|---|---|---|
| Conductor(s) | 0.419 Ohm/1000ft (1.37 Ohm/km) | 75 Amps per Conductor at 30oC |
| Ground Wire | 0.667 Ohm/1000ft (2.19 Ohm/km) |
Voltage
| Voltage Rating | 1000 V (TECK 90) |
|---|
Mechanical Characteristics
| Max. Pull Tension | 1114.2 lbs (505.39 kg) |
|---|---|
| Bulk Cable Weight | 535 lbs/1000ft (796 kg/km) |
Temperature
| Operating | -40°C To +90°C |
|---|---|
| Installation | -25°C To +90°C |
Bend Radius
| Stationary Min. | 8.37 in (213 mm) |
|---|---|
| Installation Min. | 8.37 in (213 mm) |
Standards and Compliance
| Environmental Suitability | Indoor, Outdoor, Sunlight Resistance, UV Resistance, Burial |
|---|---|
| CEC / C(UL) Compliance | TECK 90, HL. |
| European Directive Compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| APAC Compliance | China RoHS II (GB/T 26572-2011) |
History
| Update and Revision | Revision Number: 0.303 Revision Date: 03-11-2026 |
|---|
Resources
Related control cable

1285
RW90 1000V, 4 Str BC, XLPE Ins, 90C Dry/Wet CSA HL SUN RES
1 · BC - Bare Copper · XLP, XLPO, XLPE (Thermoset) · PVC - Polyvinyl Chloride

19105
Portable Cordage, 3 C #10 Str BC, EPDM Ins, Rubber Jkt, UL Type S
3 · 10 AWG · BC - Bare Copper · EPDM - Ethylene Propylene Diene Monomer

19106
Portable Cordage, 3 C #12 Str BC, EPDM Ins, Rubber Jkt, UL Type S
3 · 12 AWG · BC - Bare Copper · EPDM - Ethylene Propylene Diene Monomer

19107
Portable Cordage, 3 C #14 Str BC, EPDM Ins, Rubber Jkt, UL Type S
3 · 14 AWG · BC - Bare Copper · EPDM - Ethylene Propylene Diene Monomer