Teck90 600V, 10+G C #10+12 Str BC, XLPE Ins M4, PVC Jkt, AIA Armor, Blk PVC Jkt, CSA HL SUN RES -40C

Teck90 600V, 10+G Conductor 10+12AWG (7x18H) Bare Copper, XLPE Insulation M4 Color Code, PVC Inner Jacket, Aluminum Interlock Armor, Black PVC Outer Jacket, CSA HL SUN RES -40C

Availability
Global
Status
Active
Orderable items
7

Ships from and sold by A5 IT.

Part numbers

C5568 is a product family. Each item number below is a separate orderable part — colour, put-up and length differ.

Item #Putup TypeOrder
C5568 002984ReelOrder online
C5568 0101641ReelOrder online
C5568 0102500ReelOrder online
C5568 0105000ReelOrder online
C5568 0107500ReelOrder online
C5568 010984ReelOrder online
C5568 0103281ReelOrder online

Specifications

Product Overview

Suitable ApplicationsCEC Power and Control Applications up to 600V

Construction Details

Overall Cable Diameter (Nominal)1.178 in (29.92 mm)

Conductor

ElementNo. of ElementsSizeStrandingMaterial
Conductor(s)1010 AWG7x18BC - Bare Copper
Ground Wire112 AWG7x20BC - Bare Copper

Insulation

ElementMaterialNom. ThicknessNom. Insulation DiameterColor Code
Conductor(s)XLP, XLPO, XLPE (Thermoset)0.030 in (0.76 mm)0.174 in mmBlack and Numbered
Ground WireNo Insulation

Outer Shield

MaterialNo Shield

Inner Jacket

MaterialPVC - Polyvinyl Chloride
Nom. Thickness0.063 in (1.6 mm)
Nom. Diameter0.822 in (20.9 mm)

Armor

Armor Type & MaterialAIA - Aluminum Interlock Armor
Diameter Over Armor1.082 in (27.48 mm)

Outer Jacket

MaterialPVC - Polyvinyl Chloride
Nom. Thickness0.048 in (1.2 mm)
Nom. Diameter1.178 in (29.92 mm)
RipcordYes

Electrical Characteristics

Electricals

ElementNom. Conductor DCRMax. Current
Conductor(s)1.07 Ohm/1000ft (3.51 Ohm/km)28 Amps per Conductor at 30oC
Ground Wire1.68 Ohm/1000ft (5.51 Ohm/km)

Voltage

Voltage Rating600 V (TECK 90)

Mechanical Characteristics

Max. Pull Tension1804.8 lbs (818.64 kg)
Bulk Cable Weight774 lbs/1000ft (1150 kg/km)

Temperature

Operating-40°C To +90°C
Installation-25°C To +90°C

Bend Radius

Stationary Min.9.42 in (239 mm)
Installation Min.9.42 in (239 mm)

Standards and Compliance

Environmental SuitabilityIndoor, Outdoor, Sunlight Resistance, UV Resistance, Burial
CEC / C(UL) ComplianceTECK 90, HL.
European Directive ComplianceEU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE)
APAC ComplianceChina RoHS II (GB/T 26572-2011)

History