Product Number: C5508

Teck90 600V, 10+G C #14+14 Str BC, XLPE Ins M4, PVC Jkt, AIA Armor, Blk PVC Jkt, CSA HL SUN RES -40C

Teck90 600V, 10+G Conductor 14+14AWG (7x22H) Bare Copper, XLPE Insulation M4 Color Code, PVC Inner Jacket, Aluminum Interlock Armor, Black PVC Outer Jacket, CSA HL SUN RES -40C

Availability
Global
Status
Active
Orderable items
6

Ships from and sold by A5 IT.

Part numbers

C5508 is a product family. Each item number below is a separate orderable part — colour, put-up and length differ.

Item #Putup TypeUPCOrder
C5508 01010000Reel612825282341Order online
C5508 0102500Reel612825282358Order online
C5508 0103280Reel—Order online
C5508 0107500Reel612825282372Order online
C5508 0101640Reel—Order online
C5508 0105000Reel612825282365Order online

Specifications

Product Overview

Suitable ApplicationsCEC Power and Control Applications up to 600V

Construction Details

Overall Cable Diameter (Nominal)0.975 in (24.8 mm)

Conductor

ElementNo. of ElementsSizeStrandingMaterial
Conductor(s)1014 AWG7x22BC - Bare Copper
Ground Wire114 AWG7x22BC - Bare Copper

Insulation

ElementMaterialNom. ThicknessNom. Insulation DiameterColor Code
Conductor(s)XLP, XLPO, XLPE (Thermoset)0.030 in (0.76 mm)0.132 in mmBlack and Numbered
Ground WireNo Insulation

Outer Shield

MaterialNo Shield

Inner Jacket

MaterialPVC - Polyvinyl Chloride
Nom. Thickness0.063 in (1.6 mm)
Nom. Diameter0.654 in (16.6 mm)

Armor

Armor Type & MaterialAIA - Aluminum Interlock Armor
Diameter Over Armor0.879 in (22.3 mm)

Outer Jacket

MaterialPVC - Polyvinyl Chloride
Nom. Thickness0.048 in (1.2 mm)
Nom. Diameter0.975 in (24.8 mm)
RipcordYes

Electrical Characteristics

Electricals

ElementNom. Conductor DCRMax. Current
Conductor(s)2.7 Ohm/1000ft (8.9 Ohm/km)17.5 Amps per Conductor at 30oC
Ground Wire2.67 Ohm/1000ft (8.76 Ohm/km)

Voltage

Voltage Rating600 V (TECK 90)

Mechanical Characteristics

Max. Pull Tension200 lbs (91 kg)
Bulk Cable Weight446 lbs/1000ft (664 kg/km)

Temperature

Operating-40°C To +90°C
Installation-25°C To +90°C

Bend Radius

Stationary Min.7.8 in (200 mm)
Installation Min.7.8 in (200 mm)

Standards and Compliance

Environmental SuitabilityIndoor, Outdoor, Sunlight Resistance, UV Resistance, Burial
CEC / C(UL) ComplianceTECK 90, HL.