Belden Store
C5506

Product Number: C5506

Teck90 600V, 8+G C #14+14 Str BC, XLPE Ins M4, PVC Jkt, AIA Armor, Blk PVC Jkt, CSA HL SUN RES -40C

Teck90 600V, 8+G Conductor 14+14AWG (7x22H) Bare Copper, XLPE Insulation M4 Color Code, PVC Inner Jacket, Aluminum Interlock Armor, Black PVC Outer Jacket, CSA HL SUN RES -40C

Availability
Global
Status
Active
Orderable items
10

Ships from and sold by A5 IT.

Part numbers

C5506 is a product family. Each item number below is a separate orderable part — colour, put-up and length differ.

Item #Putup TypeUPCOrder
C5506 0101000Reel612825282266Order online
C5506 01010000Reel612825282273Order online
C5506 0102500Reel612825282297Order online
C5506 0103280Reel612825282303Order online
C5506 0105000Reel612825282310Order online
C5506 0107500Reel612825282327Order online
C5506 010984Reel—Order online
C5506 0101640Reel—Order online
C5506 0104920Reel—Order online
C5506 0106562Reel—Order online

Specifications

Product Overview

Suitable ApplicationsCEC Power and Control Applications up to 600V

Construction Details

Overall Cable Diameter (Nominal)0.884 in (22.5 mm)

Conductor

ElementNo. of ElementsSizeStrandingMaterial
Conductor(s)814 AWG7x23BC - Bare Copper
Ground Wire114 AWG7x22BC - Bare Copper

Insulation

ElementMaterialNom. ThicknessNom. Insulation DiameterColor Code
Conductor(s)XLP, XLPO, XLPE (Thermoset)0.031 in (0.79 mm)0.132 in mmBlack and Numbered
Ground WireNo Insulation

Outer Shield

MaterialNo Shield

Inner Jacket

MaterialPVC - Polyvinyl Chloride
Nom. Thickness0.063 in (1.6 mm)
Nom. Diameter0.563 in (14.3 mm)

Armor

Armor Type & MaterialAIA - Aluminum Interlock Armor
Diameter Over Armor0.788 in (20.0 mm)

Outer Jacket

MaterialPVC - Polyvinyl Chloride
Nom. Thickness0.048 in (1.2 mm)
Nom. Diameter0.884 in (22.5 mm)
RipcordYes

Electrical Characteristics

Electricals

ElementNom. Conductor DCRMax. Current
Conductor(s)2.7 Ohm/1000ft (8.9 Ohm/km)17.5 Amps per Conductor at 30oC
Ground Wire2.7 Ohm/1000ft (8.9 Ohm/km)

Voltage

Voltage Rating600 V (TECK 90)

Mechanical Characteristics

Max. Pull Tension200 lbs (91 kg)
Bulk Cable Weight386 lbs/1000ft (574 kg/km)

Temperature

Operating-40°C To +90°C
Installation-25°C To +90°C

Bend Radius

Stationary Min.7.02 in (178 mm)
Installation Min.7.02 in (178 mm)

Standards and Compliance

Environmental SuitabilityIndoor, Outdoor, Sunlight Resistance, UV Resistance, Burial
CEC / C(UL) ComplianceTECK 90, HL.
European Directive ComplianceEU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE)
APAC ComplianceChina RoHS II (GB/T 26572-2011)

History

Update and RevisionRevision Number: 0.377 Revision Date: 03-12-2026

Resources