Portable Cordage, 20 C #16 Str BC, EPDM Ins, CPE Jkt, UL Type SO
Portable Cordage, 20 Conductor 16AWG (65x34) Bare Copper, EPDM Insulation, CPE Outer Jacket, UL Type SO
- Availability
- Global
- Status
- Active
- Orderable items
- 1
Part numbers
9429 is a product family. Each item number below is a separate orderable part — colour, put-up and length differ.
| Item # | Color | UPC | Footnote | Order |
|---|---|---|---|---|
| 9429 010500 | Black | 612825244998 | C | Order online |
Specifications
Product Overview
| Suitable Applications | extra hard service cordage; oil resistant applications; to power tools and appliances |
|---|
Construction Details
| Overall Cable Diameter (Nominal) | 0.862 in |
|---|
Conductor
| Element | Conductor(s) |
|---|---|
| No. of Elements | 20 |
| Size | 16 AWG |
| Stranding | 65x34 |
| Material | BC - Bare Copper |
Insulation
| Element | Conductor(s) |
|---|---|
| Material | EPDM - Ethylene Propylene Diene Monomer |
| Nom. Thickness | 0.033 in (0.84 mm) |
| Nom. Insulation Diameter | 0.123 in (3.12 mm) |
| Color Code | Black, White, Red, Green, Orange, Blue, White/Black, Red/Black, Green/Black, Orange/Black, Blue/Black, Black/White, Red/White, Green/White, Blue/White, Black/Red, White/Red, Orange/Red, Blue/Red, Red/Green |
Outer Shield
| Material | No Shield |
|---|
Outer Jacket
| Separator | Paper Tape |
|---|---|
| Material | CPE - Chlorinated Polyethylene (Thermoset) |
| Nom. Thickness | 0.1 in (2.5 mm) |
| Nom. Diameter | 0.862 in |
| Ripcord | Yes |
Electrical Characteristics
Electricals
| Nom. Conductor DCR | 4.4 Ohm/1000ft |
|---|---|
| Max. Current | 6 Amps per Conductor at 25oC |
Voltage
| UL Voltage Rating | 600 V |
|---|
Mechanical Characteristics
| Max. Pull Tension | 650 lbs (290 kg) |
|---|---|
| Bulk Cable Weight | 445 lbs/1000ft |
Temperature
| UL Temperature | 60°C |
|---|---|
| Operating | -20°C To +60°C |
Bend Radius
| Stationary Min. | 8.62 in (219 mm) |
|---|---|
| Installation Min. | 8.62 in |
Standards and Compliance
| Environmental Suitability | Indoor, Oil Resistance |
|---|---|
| NEC / UL Compliance | Article 400, SO |
| AWM Compliance | SO |
| CEC / C(UL) Compliance | LL7874. |
| European Directive Compliance | EU CE Mark, EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| APAC Compliance | China RoHS II (GB/T 26572-2011) |
History
| Update and Revision | Revision Number: 0.355 Revision Date: 09-07-2025 |
|---|---|
| Footnote | C - CRATE REEL PUT-UP. |
Resources
Related control cable

1285
RW90 1000V, 4 Str BC, XLPE Ins, 90C Dry/Wet CSA HL SUN RES
1 · BC - Bare Copper · XLP, XLPO, XLPE (Thermoset) · PVC - Polyvinyl Chloride

19105
Portable Cordage, 3 C #10 Str BC, EPDM Ins, Rubber Jkt, UL Type S
3 · 10 AWG · BC - Bare Copper · EPDM - Ethylene Propylene Diene Monomer

19106
Portable Cordage, 3 C #12 Str BC, EPDM Ins, Rubber Jkt, UL Type S
3 · 12 AWG · BC - Bare Copper · EPDM - Ethylene Propylene Diene Monomer

19107
Portable Cordage, 3 C #14 Str BC, EPDM Ins, Rubber Jkt, UL Type S
3 · 14 AWG · BC - Bare Copper · EPDM - Ethylene Propylene Diene Monomer