Teck90 600V, 3+3+G C #6+14+8 Str BC, XLPE Ins, PVC Jkt, AIA Armor, Blk PVC Jkt, CSA HL SUN RES -40C
Teck90 600V, 3+3+G Conductor 6+14+8AWG (7x14H+7x22H) Bare Copper, XLPE Insulation, PVC Inner Jacket, Aluminum Interlock Armor, Black PVC Outer Jacket, CSA HL SUN RES -40C
- Availability
- Global
- Status
- Active
- Orderable items
- 1
Part numbers
6060 is a product family. Each item number below is a separate orderable part — colour, put-up and length differ.
| Item # | Put-Up Type | Order |
|---|---|---|
| 6060 0102500 | Reel | Order online |
Specifications
Information
| Put-Up Type | Reel |
|---|---|
| Update and Revision | Revision Number: 0.173 Revision Date: 03-18-2026 |
Product Overview
| Suitable Applications | CEC Power and Control Applications |
|---|
Physical Characteristics (Overall)
| Conductor Count | 6 |
|---|
Conductor
| Element | AWG | Stranding | Material | No. of Conductors |
|---|---|---|---|---|
| Conductor1 | 6 | 7x14 | BC - Bare Copper | 3 |
| Conductor2 | 14 | 7x22 | BC - Bare Copper | 3 |
| Ground | 8 | 7x16 | BC - Bare Copper | 1 |
Insulation
| Element | Material | Nominal Diameter | Nominal Wall Thickness |
|---|---|---|---|
| Conductor1 | XLP, XLPO, XLPE (Thermoset) | 0.300 in | 0.061 in |
| Conductor2 | XLP, XLPO, XLPE (Thermoset) | 0.131 in | |
| Ground | XLP, XLPO, XLPE (Thermoset) | 0.234 in |
Color Chart
| Number | Color |
|---|---|
| 1 | Black |
| 14 | Red |
| 2 | Blue |
| 14 | |
| 3 | |
| 14 | |
| 1 | |
| 6 | |
| 2 | |
| 6 | |
| 3 | |
| 6 |
Color Chart 2
| Color |
|---|
| Black |
| Red |
| Blue |
Color Chart 3
| Color | Green |
|---|
Inner Jacket
| Material | PVC - Polyvinyl Chloride |
|---|---|
| Nominal Diameter | 0.81 in |
Outer Jacket
| Material | Nominal Diameter |
|---|---|
| PVC - Polyvinyl Chloride | 1.16 in |
| 1.16 in |
Construction and Dimensions
Armor
| Type of Armor | Interlocked |
|---|---|
| Material | Aluminum |
Electrical Characteristics
Conductor DCR
| Nominal Conductor DCR | 0.419 Ohm/1000ft |
|---|
Current
| Max. Recommended Current [A] | 60 Amps per Conductor at 30oC |
|---|
Voltage
| Non-UL Description | Teck90 |
|---|---|
| Non-UL Voltage Rating | 600 V |
Temperature Range
| Operating Temperature Range | -40°C To +90°C |
|---|---|
| Wet Temp Range | -40°C To +90 °C |
| Dry Temp Range | -40°C To +90 °C |
Mechanical Characteristics
| UV Resistance | Yes |
|---|---|
| Bulk Cable Weight | 849 lbs/1000ft |
| Maximum Recommended Pulling Tension | 1700 lbs |
| Minimum Minor Axis Bend Radius | 11.6 in |
Applicable Environmental and Other Programs
| EU Directive Compliance | EU Directive 2003/11/EC (BFR) |
|---|---|
| MII Order #39 (China RoHS) | Yes |
Suitability
| Suitability - Indoor | Yes |
|---|---|
| Suitability - Outdoor | Yes |
| Suitability - Sunlight Resistance | Yes |
Flammability, LS0H, Toxicity Testing
| CSA/C(UL) Flammability | FT4 |
|---|
Plenum/Non-Plenum
| Plenum (Y/N) | No |
|---|
History
| Update and Revision | Revision Number: 0.173 Revision Date: 03-18-2026 |
|---|
Resources
Related control cable

1285
RW90 1000V, 4 Str BC, XLPE Ins, 90C Dry/Wet CSA HL SUN RES
1 · BC - Bare Copper · XLP, XLPO, XLPE (Thermoset) · PVC - Polyvinyl Chloride

19105
Portable Cordage, 3 C #10 Str BC, EPDM Ins, Rubber Jkt, UL Type S
3 · 10 AWG · BC - Bare Copper · EPDM - Ethylene Propylene Diene Monomer

19106
Portable Cordage, 3 C #12 Str BC, EPDM Ins, Rubber Jkt, UL Type S
3 · 12 AWG · BC - Bare Copper · EPDM - Ethylene Propylene Diene Monomer

19107
Portable Cordage, 3 C #14 Str BC, EPDM Ins, Rubber Jkt, UL Type S
3 · 14 AWG · BC - Bare Copper · EPDM - Ethylene Propylene Diene Monomer