Product Number: 9311

50 Ohm Wireless Transmission Coax, RG-58, 20 AWG Str TC, 55% TC Braid, PVC Jkt, PVC Jkt

50 Ohm Wireless Transmission Coax, RG-58, 20 AWG (19x32) Tinned Copper Conductor, PE Insulation, Duobond® Foil + 55% Tinned Copper Braid Shield, PVC Jacket, CM

Availability
Global
Status
Active
Orderable items
2

Ships from and sold by A5 IT.

Part numbers

9311 is a product family. Each item number below is a separate orderable part — colour, put-up and length differ.

Item #ColorPutup TypeLengthUPCFootnoteOrder
9311 010500BlackReel500 ft612825227847COrder online
9311 0101000BlackReel1,000 ft612825227861COrder online

Specifications

Product Overview

Suitable ApplicationsPoint-to-point and point-to-multipoint wireless antenna communication; Wireless microphones, Two-Way Radios, Amateur (Ham) Radio, Low Power FM, GPS, RFID (Radio Frequency Identification)

Construction Details

RG Type58
Overall Cable Diameter (Nominal)0.193 in (4.90 mm)

Conductor

No. of Elements1
Size20 AWG
Stranding19x32
Nom. Diameter0.037 in
MaterialTC - Tinned Copper

Insulation

MaterialPE - Polyethylene (Foam)
Nom. Insulation Diameter0.116 in (2.95 mm)
Color CodeWhite

Outer Shield

LayerOuter Shield TypeMaterialMaterial Trade NameCoverage
1TapeTri-Laminate (Alum+Poly+Alum)Duofoil®100%
2BraidTinned Copper (TC)55%

Outer Jacket

MaterialPVC - Polyvinyl Chloride
Nom. Diameter0.193 in (4.90 mm)

Electrical Characteristics

Electrical Characteristics Notes300 V RMS (CM) 30 V RMS (UL AWM Style 1354

Attenuation

FrequencyNom. Attenuation
1 MHz0.5 dB/100ft
10 MHz1.5 dB/100ft
50 MHz2.9 dB/100ft
100 MHz4 dB/100ft
200 MHz5.7 dB/100ft
400 MHz8.5 dB/100ft
700 MHz12.2 dB/100ft
900 MHz14.5 dB/100ft
1000 MHz15.8 dB/100ft

Electricals

Nom. Conductor DCR8.8 Ohm/1000ft (29 Ohm/km)
Nom. Outer Shield DCR17 Ohm/1000ft (56 Ohm/km)
Nom. Capacitance Cond-to-Shield26 pF/ft (85 pF/m)
Nom. Characteristic Impedance52 Ohm
Nom. Velocity of Prop.75%

Voltage

UL Voltage Rating300 V RMS, 30 V RMS

Mechanical Characteristics

Max. Pull Tension55 lbs (25 kg)
Bulk Cable Weight21 lbs/1000ft (31 kg/km)

Temperature

UL Temperature80°C
Operating-40°C To +80°C

Bend Radius

Stationary Min.1.93 in (49.0 mm)
Installation Min.1.93 in (49.0 mm)

Standards and Compliance

Environmental SuitabilityIndoor (Not Riser or Plenum), Indoor
Flammability / Reaction to FireUL1685 UL Loading
CPR ComplianceCPR Euroclass: Eca
NEC / UL ComplianceArticle 800, CM
AWM ComplianceAWM 1354 (30 V 80°C)
CEC / C(UL) ComplianceCM.
European Directive ComplianceEU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE)
UK Regulation ComplianceUKCA Mark
APAC ComplianceChina RoHS II (GB/T 26572-2011)

History

Update and RevisionRevision Number: 0.634 Revision Date: 04-02-2026
FootnoteC - CRATE REEL PUT-UP.

Resources