Belden Store
89880

Product Number: 89880

50Ω, #12 Sol BC, FFEP Ins, Duobond IV® quad shield, PVDF Jkt, CMP

Ethernet 50 Ω 10BASE5, 12 AWG solid bare copper conductor, foam FEP insulation, Overall Duobond® II+Tinned Copper Braid (90%)+Duofoil®+Tinned Copper Braid(90%) Shield, fluorocopolymer jacket, CMP

Availability
Global
Status
Active
Orderable items
2

Ships from and sold by A5 IT.

Part numbers

89880 is a product family. Each item number below is a separate orderable part — colour, put-up and length differ.

Item #ColorPutup TypeLengthUPCFootnoteOrder
89880 0031000OrangeReel1,000 ft612825221364COrder online
89880 0031640OrangeReel1,640 ft612825221371C ZOrder online

Specifications

Product Overview

Suitable ApplicationsThick Ethernet (IEEE 802.3 10BASE5)

Construction Details

Overall Cable Diameter (Nominal)0.365 in (9.27 mm)

Conductor

Size12 AWG
StrandingSolid
Nom. Diameter0.086 in
MaterialBC - Bare Copper

Insulation

MaterialFEP - Fluorinated Ethylene Propylene (Foam)
Nom. Insulation Diameter0.245 in (6.22 mm)
Color CodeClear

Outer Shield

LayerOuter Shield TypeMaterialMaterial Trade NameCoverage
1TapeTri-Laminate (Alum+Poly+Alum)Duobond® II100%
2BraidTinned Copper (TC)90%
3TapeTri-Laminate (Alum+Poly+Alum)Duofoil®100%
4BraidTinned Copper (TC)90%

Outer Jacket

MaterialPVDF - Polyvinylidene Fluoride
Nom. Diameter0.365 in (9.27 mm)

Electrical Characteristics

Attenuation

FrequencyNom. Attenuation
1 MHz0.18 dB/100ft
5 MHz0.37 dB/100ft
10 MHz0.52 dB/100ft
50 MHz1.15 dB/100ft
100 MHz1.65 dB/100ft
200 MHz2.45 dB/100ft
400 MHz3.80 dB/100ft
700 MHz5.60 dB/100ft
900 MHz6.80 dB/100ft
1000 MHz7.20 dB/100ft

Power Rating

FrequencyMax. Power Rating
1 MHz15,900 W
5 MHz6,928 W
10 MHz4,802 W
50 MHz1,992 W
100 MHz1,344 W
200 MHz900 W
400 MHz602 W
700 MHz438 W
900 MHz382 W
1,000 MHz361 W

Electricals

Nom. Conductor DCR1.4 Ohm/1000ft
Nom. Outer Shield DCR1.5 Ohm/1000ft (4.9 Ohm/km)
Nom. Capacitance Cond-to-Shield26.0 pF/ft (85.3 pF/m)
Nom. Characteristic Impedance50 Ohm
Nom. Velocity of Prop.78%

Voltage

UL Voltage Rating300 V (CMP)
Voltage Rating600 V

Mechanical Characteristics

Max. Pull Tension255 lbs (116 kg)
Bulk Cable Weight137 lbs/1000ft

Temperature

UL Temperature150°C
Operating-25°C to +150°C

Bend Radius

Installation Min.6.0 in (150 mm)

Standards and Compliance

Environmental SuitabilityIndoor - Plenum, Indoor
SustainabilityCA Prop 65
Flammability / Reaction to FireNFPA 262
CPR ComplianceCPR Euroclass: Eca
NEC / UL ComplianceCL2P, CMP
CEC / C(UL) ComplianceCMP.
IEEE ComplianceIEEE 802.3 10Base5
European Directive ComplianceEU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), REACH, EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE)
UK Regulation ComplianceUKCA Mark
APAC ComplianceChina RoHS II (GB/T 26572-2011)
Other Standard Compliance(s)DEC Part No. 17-00324-00
Non-Plenum Number9880

Product Notes

NotesRing-band stripes every 2.5 meters to aid users in tap placement.

History

Update and RevisionRevision Number: 0.501 Revision Date: 02-20-2026
FootnoteC - CRATE REEL PUT-UP., Z - FINAL PUT-UP MAY VARY (= OR -) 10% FOR SPOOLS OR REELS AND (+ OR -) 5% FOR UNREEL CARTONS FROM LENGTH SHOWN.