SMPTE 311M Cable, 2 Fiber, 2 Conductor 24 AWG, 4 Conductor 20 AWG, Belflex® Jacket, CMR
Industry Standard SMPTE 311M Cable, 2 Single Mode Fibers, 2 TC Conductors 24 AWG (7x32) and 4 TC Conductors 20 AWG (19x32), PVC Insulation, TC Braid Shield (95% coverage), Belflex® Jacket, Riser
- Availability
- Global
- Status
- Active
- Orderable items
- 3
Part numbers
7804R is a product family. Each item number below is a separate orderable part — colour, put-up and length differ.
| Item # | Put-Up Type | UPC | Order |
|---|---|---|---|
| 7804R B59CUT | Reel | 612825189503 | Order online |
| 7804R B591000 | Reel | 612825378648 | Order online |
| 7804R B593280 | Reel | 612825189497 | Order online |
Specifications
Product Overview
| Product Category | SMPTE Cable |
|---|
Fiber Specifications
| Fiber Type | OS2, G.657.A2 |
|---|---|
| Fiber Buffer Material | PVC - Polyvinyl Chloride |
| Fiber Buffer Diameter | 900 μm |
| Fiber Count | 2 |
| Fiber Color Code | Yellow, Blue |
Conductor Specifications
| Conductor Size | 24 AWG, 20 AWG |
|---|---|
| Insulation Material | Polyolefin (PO, PE, PP) |
Outer Jacket Specifications
| Jacket Material | PVC - Polyvinyl Chloride |
|---|---|
| Nom. Diameter | 0.357 in (9.07 mm) |
Optical Characteristics
| Wavelength | Max. Attenuation |
|---|---|
| 1310 nm | 0.50 dB/km |
| 1550 nm | 0.50 dB/km |
Mechanical Characteristics
| Bulk Cable Weight | 80 lbs/1000ft (120 kg/km) |
|---|
Temperature Range
| Operating Temperature Range | -40°C to +70°C |
|---|---|
| Installation Temperature Range | -10°C to +70°C |
| Storage Temperature Range | -40°C to +70°C |
Standards and Compliance
| Environmental Suitability | Indoor/Outdoor, Indoor |
|---|---|
| Flammability / Reaction to Fire | UL1666 Vertical Shaft, FT4 |
| NEC / UL Compliance | CMR |
| CEC / C(UL) Compliance | CMG. |
| CPR Euroclass | Eca |
| European Directive Compliance | EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
History
| Update and Revision | Revision Number: 0.334 Revision Date: 09-25-2025 |
|---|
Resources
Related smpte camera cable

2804RW
Indoor/Outdoor Stadium Cable, SMPTE 311M, 2 Fiber, 2 Conductor 24 AWG, 4 Conductor 20 AWG, CPE Jacket
3 items

2824RW
Indoor/Outdoor Stadium Cable, 3-Channel SMPTE, 6 Fiber, 6 Conductor 18 AWG, 6 Conductor 24 AWG, CPE Jacket
3 items
7804C
SMPTE 311M Cable, 2 Fiber, 2 Conductor 24 AWG, 2 Conductor 16 AWG, Belflex® Jacket, CMR
1 item

7804LW
Light Duty SMPTE 311M Cable, 2 Fiber, 2 Conductor 24 AWG, 4 Conductor 20 AWG, Belflex®Jacket
3 items