Indoor/Outdoor Stadium Cable, 3-Channel SMPTE, 6 Fiber, 6 Conductor 18 AWG, 6 Conductor 24 AWG, CPE Jacket
Indoor/Outdoor, 3-Channel SMPTE Stadium Cable, 6 Single Mode Fibers, 6 TC Conductor 18 AWG (19x30) and 6 TC Conductor 24 AWG (7x32), Beldfoil Shields, Water Blocking Tape, CPE Jacket
- Availability
- Global
- Status
- Active
- Orderable items
- 3
Part numbers
2824RW is a product family. Each item number below is a separate orderable part — colour, put-up and length differ.
| Item # | Put-Up Type | Order |
|---|---|---|
| 2824RW 005CUT | Reel | Order online |
| 2824RW 0051000 | Reel | Order online |
| 2824RW 0055000 | Reel | Order online |
Specifications
Product Overview
| Product Category | SMPTE Cable |
|---|---|
| Suitable Applications | 3 Channel Composite Camera Cable |
Fiber Specifications
| Fiber Type | OS2, G.657.A2 |
|---|---|
| Fiber Buffer Material | PVC - Polyvinyl Chloride |
| Fiber Buffer Diameter | 900 μm |
| Fiber Count | 6 |
| Fiber Color Code | Yellow Printed |
Fiber Construction
| Subunit Waterblocking | Aramid Yarn |
|---|---|
| Fibers Per Subunit | 1 |
Conductor Specifications
| Conductor Size | 24 AWG, 18 AWG |
|---|---|
| Insulation Material | PVC |
Outer Jacket Specifications
Optical Characteristics
| Wavelength | Max. Attenuation |
|---|---|
| 1310 nm | 0.50 dB/km |
| 1550 nm | 0.50 dB/km |
Mechanical Characteristics
| Bulk Cable Weight | 134 lbs/1000ft (199 kg/km) |
|---|
Temperature Range
| Operating Temperature Range | -40°C to 70°C |
|---|---|
| Installation Temperature Range | -10°C to 70°C |
| Storage Temperature Range | -40°C to 70°C |
Standards and Compliance
| Environmental Suitability | Indoor - Riser, Indoor, Outdoor |
|---|---|
| Flammability / Reaction to Fire | UL1666 Vertical Shaft |
| NEC / UL Compliance | CMR |
| European Directive Compliance | EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| APAC Compliance | China RoHS II (GB/T 26572-2011) |
Product Notes
| Notes | Copper conductor quads are individually shielded with individual drain wire |
|---|
History
| Update and Revision | Revision Number: 0.147 Revision Date: 09-07-2025 |
|---|
Resources
Related smpte camera cable

2804RW
Indoor/Outdoor Stadium Cable, SMPTE 311M, 2 Fiber, 2 Conductor 24 AWG, 4 Conductor 20 AWG, CPE Jacket
3 items
7804C
SMPTE 311M Cable, 2 Fiber, 2 Conductor 24 AWG, 2 Conductor 16 AWG, Belflex® Jacket, CMR
1 item

7804LW
Light Duty SMPTE 311M Cable, 2 Fiber, 2 Conductor 24 AWG, 4 Conductor 20 AWG, Belflex®Jacket
3 items

7804P
SMPTE 311M Cable, 2 Fiber, 2 Conductor 24 AWG, 4 Conductor 20 AWG, Flamarrest® Jacket
4 items