SMPTE 311M Cable, 2 Fiber, 2 Conductor 24 AWG, 4 Conductor 20 AWG, Flamarrest® Jacket
Industry Standard SMPTE 311M Cable, 2 Single Mode Fibers, 2 TC Conductors 24 AWG (7x32) and 4 TC Conductors 20 AWG (19x32), PVC Insulation, TC Braid Shield (95% coverage), Flamarrest® Jacket, Plenum
- Availability
- Global
- Status
- Active
- Orderable items
- 4
Part numbers
7804P is a product family. Each item number below is a separate orderable part — colour, put-up and length differ.
| Item # | Put-Up Type | Order |
|---|---|---|
| 7804P 010CUT | Reel | Order online |
| 7804P 0101000 | Reel | Order online |
| 7804P 0103280 | Reel | Order online |
| 7804P 0105000 | Reel | Order online |
Specifications
Product Overview
| Product Category | SMPTE Cable |
|---|---|
| Suitable Applications | SMPTE 311 |
Fiber Specifications
| Fiber Type | OS2, G.657.A2 |
|---|---|
| Fiber Buffer Material | PVC - Polyvinyl Chloride |
| Fiber Buffer Diameter | 900 μm |
| Fiber Count | 2 |
| Fiber Color Code | Yellow, Blue |
Conductor Specifications
| Conductor Size | 24 AWG, 20 AWG |
|---|---|
| Insulation Material | FEP |
Outer Jacket Specifications
| Jacket Material | PVC - Polyvinyl Chloride |
|---|---|
| Nom. Diameter | 0.259 in (6.58 mm) |
Optical Characteristics
| Wavelength | Max. Attenuation |
|---|---|
| 1310 nm | 0.50 dB/km |
| 1550 nm | 0.50 dB/km |
Mechanical Characteristics
| Bulk Cable Weight | 62 lbs/1000ft (92 kg/km) |
|---|
Temperature Range
| Operating Temperature Range | -20°C to 70°C |
|---|---|
| Installation Temperature Range | 0°C to 70°C |
| Storage Temperature Range | -20°C to 70°C |
Standards and Compliance
| Environmental Suitability | Indoor - Plenum, Indoor |
|---|---|
| Flammability / Reaction to Fire | UL910 Steiner Tunnel, FT6 |
| NEC / UL Compliance | CMP |
| CEC / C(UL) Compliance | CMP. |
| European Directive Compliance | EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
History
| Update and Revision | Revision Number: 0.250 Revision Date: 09-25-2025 |
|---|
Resources
Related smpte camera cable

2804RW
Indoor/Outdoor Stadium Cable, SMPTE 311M, 2 Fiber, 2 Conductor 24 AWG, 4 Conductor 20 AWG, CPE Jacket
3 items

2824RW
Indoor/Outdoor Stadium Cable, 3-Channel SMPTE, 6 Fiber, 6 Conductor 18 AWG, 6 Conductor 24 AWG, CPE Jacket
3 items
7804C
SMPTE 311M Cable, 2 Fiber, 2 Conductor 24 AWG, 2 Conductor 16 AWG, Belflex® Jacket, CMR
1 item

7804LW
Light Duty SMPTE 311M Cable, 2 Fiber, 2 Conductor 24 AWG, 4 Conductor 20 AWG, Belflex®Jacket
3 items