GIGABIX CONNECTOR 25-PAIR
GIGABIX CONNECTOR 25-PAIR
- Availability
- Global
- Status
- Active
- Orderable items
- 1
Part numbers
AX101448 is a product family. Each item number below is a separate orderable part — colour, put-up and length differ.
| Item # | Color | UPC | Order |
|---|---|---|---|
| AX101448 | White | 611589002783 | Order online |
Specifications
Product Overview
| Suitable Applications | IBDN System 4800, 3600, 2400, TIA Category 6, ISO Class E, 1000BASE-T |
|---|
Physical Characteristics (Overall)
| Packaging | packaged in carton; Standard pack of 12 units |
|---|---|
| Weight | 0.11 g |
Insulation
| Nominal Diameter | 0.146 mm |
|---|
Connectors
Materials
| Description | Material | Type |
|---|---|---|
| Front Connection | Copper Allow with Nickel Plating | IDC |
| Rear Connection | Copper Allow with Nickel Plating | IDC |
| Connector Body | Plastic - UL940V-0 |
Construction and Dimensions
| OuterJacket1, Nom Thick Twisted Section | 0.147 mm |
|---|
Electrical Characteristics
| Dielectric Strength | 1,000V RMS @ 60 Hz for 1 minute kV DC |
|---|---|
| Current Rating | 1.5 A |
| Insulation Resistance | 100 MOhm*km |
| Max Contact Resistance | 1 mOhm |
Inductance
| Nominal Inductance | 0.145 μH/m |
|---|
Mated Connection
| Frequency (MHz) | 100 |
|---|---|
| Max. Insertion Loss TIA* (dB) | 0.2 dB |
| Min. NEXT TIA* (dB) | 54 dB |
| Min. FEXT TIA* (dB) | 43.1 dB |
| Min. FEXT Belden** (dB) | 58.8 dB |
| Min. Return Loss TIA* (dB) | 24 dB |
Temperature Range
| Installation Temperature Range | -10°C To +60°C |
|---|---|
| Storage Temperature Range | -40°C To +70°C |
| Operating Temperature Range | -10°C To +60°C |
Mechanical Characteristics
| Connector System Compatibility | GigaBIX |
|---|---|
| Tool Compatibility | BIX Connecting Tool (A0270165) |
Termination Interface
| Termination | Connection | Durabilities |
|---|---|---|
| Front | Gas Tight IDC Connection | 200 terminations |
| Rear | Gas Tight IDC Connection | 200 terminations |
Dimensions
| Width | 6.63 |
|---|---|
| Height | 0.31 |
| Depth | 1.28 |
Standards
| ISO/IEC Compliance | ISO/IEC 11801:2002 |
|---|---|
| Data Category | Category 6 |
| TIA/EIA Compliance | ANSI/TIA/EIA 568 C.2 Category 6 |
| Third Party Performance Verification | ETL - Verified Category 6 |
Applicable Environmental and Other Programs
| Environmental Space | Indoor |
|---|---|
| EU Directive Compliance | EU Directive 2002/95/EC (RoHS) |
Suitability
| Suitability - Indoor | Yes |
|---|
Flammability, LS0H, Toxicity Testing
| Safety Listing | ACA,UL 1863 and CSA-C22.2 |
|---|
Related Part Numbers
| Related Parts | Compatible with GigaBIX patch cord, GigaBIX termination kit, GigaBIX rack mount panel, designation strips, wire guard |
|---|
Product Notes
| Notes | For proper installation refer to Installation Guide PX101813 (French) or PX101814 (English) included with the product or visit our web site at http://www.belden.com |
|---|
History
| Update and Revision | Revision Number: 0.101 Revision Date: 02-20-2026 |
|---|