XTran PSU 88-300 VDC for XT-2215-A nodes
XTran DC Power Supply with 88-300 VDC input for XT-2215-A
- Availability
- Global
- Status
- Active
Specifications
Product Overview
| Product Category | Power Supplies |
|---|---|
| Name | V30912-A5020-A6 |
| Power Supply Protection | Auto recoverable: Overtemperature / Overcurrent / Overvoltage |
| Power Supply Efficiency | At 230VDC (full load): 89% (measured including fans) |
| Output Power | 900W |
Power requirements
| Input Voltage | 88-300VDC (nominal 230 VDC, tolerance according to EN62368-1) |
|---|---|
| Inrush Current Max | Cold start (full load) ETSI 300-132: < 30 Apk, at 230VDC |
Ambient conditions
| MTBF (MIL-HDBK 217F: Gb 25 oC) | 34 years with 2 units in a chassis, 900W Load |
|---|---|
| Operating Temperature Range | -20° to +55°C (-4° to 131°F) |
| Storage Temperature Range | -30° to +75°C (-22° to 167°F) |
| Relative humidity (non-condensing) | 0-95 % |
Mechanical Construction
| Overall Width | 200.0 mm |
|---|---|
| Overall Height | 44.5 mm |
| Overall Depth | 285.8 mm |
| Weight | 2.62 kg |
| Power Supply Connector | PC 4/ 3-G-7,62 and BF-PC 4 on front panel, SPC 5/ 3-STF-7,62 for cable |
| Node Compatibility | XT-2215-A |
Approvals
| Basis Standard | CE, EN 55032:2015 + A11:2020, EN IEC 61000-3-2:2019, EN 61000-3-3:2013 + A2 :2021, EN 55035:2017 + A11:2020, EN IEC 61000-6-1:2019, EN IEC 61000-6-2:2019, EN IEC 61000-6-3:2021, EN IEC 61000-6-4:2019 |
|---|---|
| Safety of industrial control equipment | EN 62368-1:2014 |
| Power Utility | EN 61000-6-5:2015, EN 61850-3:2014 (§6.7), IEEE 1613-2009 (§4), IEEE1613-2013 (clause 5,7,8,9,10) |
| Transportation | EN 50121-4:2016 + A1:2019 |
Reliability
| Guarantee | Standard 1 year (extension possible) |
|---|
Scope of delivery and accessories
| Accessories to Order Separately | PSU cable for DCP-D power supply: S30927-C17-A30 |
|---|
Further Instructions
| Product Documentation | Available via Belden Solutions Portal site |
|---|---|
| Certificates | Available via Belden Solutions Portal site |
History
| Update and Revision | Revision Number: 0.29 Revision Date: 12-16-2025 |
|---|
Resources
Belden DCP-D technical datasheetUninterrupted Power: 10 Ways MLPS-TP Technology Reinforces Utility NetworksMPLS-TP: A Superior Packet-based Technology for Industrial ApplicationsMPLS-TP Helps Mass Transit Move from Two Networks to OneMPLS-TP or IP/MPLS Networking Protocol: Which Is Best for Your Utility?Why MPLS Is Geared for YouMPLS-TP for Utilities: It's Time for New Backbone TechnologyISO 9001:2015 OlenXTran Core NodeXTran Modular Aggregation NodesXTran Access Node XTD-2110-AXTran Access Node XTR-2124-A(F)Video Network Slicing