Belden Store
BeldenRSFM 4/20 M

Product Number: RSFM 4/20 M

M12 Standard Sensor/Actuator Receptacle Connector: Male, front mount, M12 - mating side, stranded wires - connecting side, 4-pin, A-coded, unshielded, metallic grey housing, 230 V AC/DC, 4 A

M12 Standard Sensor/Actuator Receptacle Connector: Male, front mount, M12 - mating side, stranded wires - connecting side, 4-pin, A-coded, unshielded, metallic grey housing, 230 V AC/DC, 4 A

Availability
Global
Status
Active
Orderable items
3

Ships from and sold by A5 IT.

Part numbers

RSFM 4/20 M is a product family. Each item number below is a separate orderable part — colour, put-up and length differ.

Item #Item DescriptionCable LengthOrder
80492RSFM 4/20/0,2 M0.2 mOrder online
26145RSFM 4/20/0,5 M0.5 mOrder online
9319RSFM 4/20/1 M1 mOrder online

Specifications

Information

Product FamilySensor / Actuator Connectors
Side 1 Product Sub FamilyM12 Standard
Mating SideM12
Connecting SideStranded Wires
Connector TypeReceptacle
Side 1 Type of Contact/GenderMale
Connector DesignFront Mount
Number of Pins4
Coding, Side 1A
Attachment TypeScrew-Locking
Voltage Rating250 V
Rated Voltage (UL)300 V AC/DC
Rated Impulse Voltage2.5 kV
Operating Voltage230 V AC/DC
Current Rating4 A
Rated Current (UL)*4 A
Side 1 Contact Resistance≤ 10 mOhm
Insulation Resistance˃ 10^9 Ohm
Mating Cycles≤ 100
Type of ConnectionSolder
Thread SizeM20x1.5
Ambient Temperature (Operation)*- 25 °C - + 85 °C
Operating Temperature (UL)max. + 50 °C
Protection Degree / IP Rating**IP65, IP67
Side 1 Design StandardIEC 61076-2-101
Side 1 Pollution Degree3 acc. to DIN EN 60664-1 (VDE 0110-1)
Clearance / Creepage DistanceDIN EN 60664-1 (2008/01); VDE 0110-1
Overvoltage CategoryII acc. to DIN EN 60664-1 (VDE 0110-1)
Note Derating* Notice derating
Protection Degree / IP Rating Note* only if mounted and locked in combination with Hirschmann / Lumberg connector. On the installation side tightness has to be assured by taking proper measures.
NoteThe receptacle connector is constructively intended for usage in IP67-products. To realise this protection class, the estimated location has to be designed accordingly. Further details see IEC 61076-2-101. Connection area must be epoxy potted.
UL NoteThe receptacle connector is constructively intended for usage in IP67-products. To realise this protection class, the estimated location has to be designed accordingly. Further details see IEC 61076-2-101

Face View

Pin 1brown
Pin 2white
Pin 3blue
Pin 4black

Materials

Contact Base MaterialCuZn
Side 1 Contact PlatingCu/Au
Contact Bearer MaterialPA
Contact Bearer ColorBlack
Flammability Class (Contact Bearer)UL 94 V-0
PottedYes
Housing MaterialCuZn
Housing PlatingNickel-plated
Housing ColorSilver
Attachment MaterialCuZn
Attachment PlatingNickel-plated
O-Ring MaterialCR

Circuitry

Fastening Torque (Attachment)M 12x1: (50-60) Ncm, hand-tight
Accessories to Order Separately000-025-048 Mounting Nut M20x1.5

Cable Data

Cable Number908 43
Conductor Size0.355 mm2
Number of Wires4
Conductor MaterialCu
Wire Insulation MaterialPVC
Insulated Wire Diameterø 1.55 mm ± 0.1 mm
Ambient Temperature (Fixed Installation)- 40 °C - + 90 °C
Ambient Temperature (Flex Installation)- 20 °C - + 90 °C
UL Cable TypeAWM: 1007
Flammability Class (Cable Jacket)DIN EN 60332-1-2, VDE 0482-332-1-2, IEC 60332-1-2, UL-VW1, CSA-FT1
Core Colorsblue,brown, white, black

Approvals

UL-FileE315587
ULcURus

Safety & Environmental Compliance

RoHS Compliantyes

Notes

Note Derating* Notice derating
Protection Degree / IP Rating Note* only if mounted and locked in combination with Hirschmann / Lumberg connector. On the installation side tightness has to be assured by taking proper measures.
NoteThe receptacle connector is constructively intended for usage in IP67-products. To realise this protection class, the estimated location has to be designed accordingly. Further details see IEC 61076-2-101. Connection area must be epoxy potted.
UL NoteThe receptacle connector is constructively intended for usage in IP67-products. To realise this protection class, the estimated location has to be designed accordingly. Further details see IEC 61076-2-101

Resources

Related lumberg automation sensor/actuator connectors