Belden Store
BeldenRKFP 5 M

Product Number: RKFP 5 M

M12 Standard Sensor/Actuator Receptacle Connector: Female, front mount positionable, M12 - mating side, stranded wires - connecting side, 5-pin, A-coded, unshielded, metallic grey housing, 50 V AC / 60 V DC, 4 A

M12 Standard Sensor/Actuator Receptacle Connector: Female, front mount positionable, M12 - mating side, stranded wires - connecting side, 5-pin, A-coded, unshielded, metallic grey housing, 50 V AC / 60 V DC, 4 A

Availability
Global
Status
Active
Orderable items
1

Ships from and sold by A5 IT.

Part numbers

RKFP 5 M is a product family. Each item number below is a separate orderable part — colour, put-up and length differ.

Item #Item DescriptionCable LengthOrder
11276RKFP 5/0,5 M0.5 mOrder online

Specifications

Information

Product FamilySensor / Actuator Connectors
Side 1 Product Sub FamilyM12 Standard
Mating SideM12
Connecting SideStranded Wires
Connector TypeReceptacle
Side 1 Type of Contact/GenderFemale
Connector DesignFront Mount Positionable
Number of Pins5
Coding, Side 1A
Attachment TypeScrew-Locking
Voltage Rating60 V
Rated Voltage (UL)30 V AC/DC
Rated Impulse Voltage1.5 kV
Operating Voltage50 V AC / 60 V DC
Current Rating4 A
Rated Current (UL)*4 A
Side 1 Contact Resistance≤ 10 mOhm
Insulation Resistance˃ 10^9 Ohm
Mating Cycles≤ 100
Type of ConnectionCrimp
Thread SizePG9
Thread MaterialCuZn
Thread PlatingNickel-plated
Ambient Temperature (Operation)*- 25 °C - + 85 °C
Operating Temperature (UL)max. + 50 °C
Protection Degree / IP Rating**IP65, IP67
Side 1 Design StandardPin assignment deviating from IEC 61076-2-101 and IEC 61140
Side 1 Pollution Degree3 acc. to DIN EN 60664-1 (VDE 0110-1)
Clearance / Creepage DistanceDIN EN 60664-1 (2008/01); VDE 0110-1
Overvoltage CategoryIII acc. to DIN EN 60664-1 (VDE 0110-1)
Note Derating* Notice derating
Protection Degree / IP Rating Note* only if mounted and locked in combination with Hirschmann / Lumberg connector. On the installation side tightness has to be assured by taking proper measures.
NoteThe receptacle connector is constructively intended for usage in IP67-products. To realise this protection class, the estimated location has to be designed accordingly. Further details see IEC 61076-2-101.
UL NoteThe receptacle connector is constructively intended for usage in IP67-products. To realise this protection class, the estimated location has to be designed accordingly. Further details see IEC 61076-2-101

Face View

Pin 1brown
Pin 2white
Pin 3blue
Pin 4black
Pin 5green-yellow

Materials

Contact Base MaterialCuSn
Side 1 Contact PlatingCu/Au
Contact Bearer MaterialTPU
Contact Bearer ColorBlack
Flammability Class (Contact Bearer)UL 94 HB
PottedYes
Housing MaterialCuZn
Housing PlatingNickel-plated
Housing ColorSilver
Attachment MaterialCuZn
Attachment PlatingNickel-plated
O-Ring MaterialFKM

Circuitry

Fastening Torque (Attachment)M 12x1: (50-60) Ncm, hand-tight

Cable Data

Cable Number908 09 / 908 43
Conductor Size4x0.355 mm2+1x0.50 mm2(GNYE)
Number of Wires5
Conductor MaterialCu
Wire Insulation MaterialPVC
Insulated Wire Diameterø 1.55 mm ± 0.1 mm / ø 1.8 mm ± 0.1 mm (GNYE)
Ambient Temperature (Fixed Installation)- 40 °C - + 90 °C
Ambient Temperature (Flex Installation)- 20 °C - + 90 °C
UL Cable TypeAWM: 1007+1679 (GNYE)
Flammability Class (Cable Jacket)DIN EN 60332-1-2, VDE 0482-332-1-2, IEC 60332-1-2, UL-VW1
Core Colorsblack, white, blue, brown, yellow/green

Approvals

UL-FileE315587
ULcURus

Safety & Environmental Compliance

RoHS Compliantyes

Notes

Note Derating* Notice derating
Protection Degree / IP Rating Note* only if mounted and locked in combination with Hirschmann / Lumberg connector. On the installation side tightness has to be assured by taking proper measures.
NoteThe receptacle connector is constructively intended for usage in IP67-products. To realise this protection class, the estimated location has to be designed accordingly. Further details see IEC 61076-2-101.
UL NoteThe receptacle connector is constructively intended for usage in IP67-products. To realise this protection class, the estimated location has to be designed accordingly. Further details see IEC 61076-2-101

Resources

Related lumberg automation sensor/actuator connectors