Belden Store
BeldenRSWT 5L-1001 SW

Product Number: RSWT 5L-1001 SW

M12 Power | Cordset | Male Angled → Open End, 5-pin L-code, TPE (1.50 mm2) 16 AWG, 63 V / 16 A

M12 Power | Single-Ended Cordset | M12 Male Angled, #Contacts 5 (4+FE), L-code → Open End | Cable: Black TPE; 1.50 mm2 (16 AWG) | 63 V / 16 A

Availability
Global
Status
Active

Ships from and sold by A5 IT.

Specifications

Information

Product FamilyPower Connector
Side 1 Product Sub FamilyM12 Power
Connector TypeCordset, single ended
Side 1 Type of Contact/GenderPin Contact / Male
Connector DesignMolded | M12 Male | Angled
Number of Pins5 (4+FE)
Coding, Side 1L
Shielding TypeUnshielded
Attachment TypeCoupling Screw
Voltage Rating63 V
Rated Voltage (UL)63 V
Rated Impulse Voltage1.5 kV
Operating Voltage60 V AC/DC
Current Rating16 A
Rated Current (UL)*16 A
Side 1 Contact Resistance≤ 10 mOhm
Insulation Resistance˃ 10^9 Ohm
Mating Cycles≤ 100
Ambient Temperature (Operation)*- 40 °C to + 125 °C, notice derating
Protection Degree / IP Rating**IP65, IP67, IP69k
Side 1 Design StandardIEC 61076-2-111
Side 1 Pollution Degree3 acc. to IEC 60664-1
Clearance / Creepage DistanceIEC 60664-1 (2020-05)
Overvoltage CategoryIII acc. to IEC 60664-1
Note Derating* Notice derating
Protection Degree / IP Rating NoteIP Rating tested according to IEC standard using combination of a Hirschmann or Lumberg Automation connector mounted and locked
Note1. Do not connect or disconnect under load.

Face View

Pin 1brown
Pin 2white
Pin 3blue
Pin 4black
FEgrey

Materials

Contact Base MaterialCopper Alloy (CuNi)
Side 1 Contact PlatingGold over Copper (Cu/Au)
Contact Bearer MaterialGlass-filled Polybutylene Terephthalate (PBT GF)
Contact Bearer ColorGrey
Flammability Class (Contact Bearer)UL 94 V-2
Molded Body MaterialThermoplastic Elastomer (TPE)
Molded Body ColorBlack
Flammability Class (Molded Body)UL 94 HB
Attachment MaterialCopper Alloy (CuZn)
Attachment PlatingNickel (Ni)

Circuitry

Fastening Torque (Attachment)M 12x1: (50-60) Ncm, hand-tight

Cable Data

Cable Number1001
Conductor Size1.50 mm2
Number of Wires5
Minimal Bending Radius (Fixed Inst)˃ 4 x D
Minimal Bending Radius (Flexible Inst)˃ 7.5 x D
Cycles (Bending)˃ 2 Mio, max. 50 m/s2
Conductor MaterialCu
Cable Jacket MaterialThermoplastic Elastomer (TPE)
Cable Jacket ColorBlack
Cable Diameter DØ 9.4 | 0.370"
Wire Insulation MaterialPolyvinyl Chloride-Polyamide (PVC-PA)
Insulated Wire DiameterØ 2.55 mm | 0.100 "
Overall Shield (Cable)Unshielded
Ambient Temperature (Fixed Installation)- 40° C to + 90° C
Ambient Temperature (Flex Installation)- 5° C to + 90° C
UL Cable TypeNEC: TC-ER or AWM Style 20328
Flammability Class (Cable Jacket)UL 1685 FT4/IEEE 1202 Vertical Tray Flame Test, FT4
Cable CharacteristicsFlexibility: Excellent | Abrasion Resistance: Good to Excellent | Oil & Chemical Resistance: Good, OIL RES II | UV Resistance: Good, SUN RES | Low Temp Performance: Good to Excellent (flexible to -40°C) | Flame Retardance: UL1685 FT4/IEEE 1202 Vertical Tray Flame Test | Halogen-Free: No | Mechanical Durability: Good to High (resists impact, tear, and flex) | Environmental Suitability: Outdoor, oily, wet, or rough environments

Approvals

UL-FileE497237
ULUL 2237; cULus

Safety & Environmental Compliance

RoHS CompliantYes

Resistances

HalogenfreeNo
Oil ResistanceOil Res II

Notes

Note Derating* Notice derating
Protection Degree / IP Rating NoteIP Rating tested according to IEC standard using combination of a Hirschmann or Lumberg Automation connector mounted and locked
Note1. Do not connect or disconnect under load.

Resources