Belden Store
RST 4S-733

Product Number: RST 4S-733

M12 Power | Cordset | Male Straight → Open End, 4-pin S-code, PVC (1.50 mm2) 16 AWG, 630 V / 16 A

M12 Power | Single-Ended Cordset | M12 Male Straight, #Contacts 4, S-code → Open End | Cable: Black PVC; 1.50 mm2 (16 AWG) | 630 V / 16 A

Availability
Global
Status
Active
Orderable items
4

Ships from and sold by A5 IT.

Part numbers

RST 4S-733 is a product family. Each item number below is a separate orderable part — colour, put-up and length differ.

Item #Item DescriptionCable LengthOrder
934851005RST 4S-733/2 M2 mOrder online
934851006RST 4S-733/5 M5 mOrder online
934851007RST 4S-733/10 M10 mOrder online
934851008RST 4S-733/15 M15 mOrder online

Specifications

Information

Product FamilyPower Connector
Side 1 Product Sub FamilyM12 Power
Connector TypeCordset, single ended
Side 1 Type of Contact/GenderPin Contact / Male
Connector DesignMolded | M12 Male | Straight
Number of Pins4 (3+PE)
Coding, Side 1S
Shielding TypeUnshielded
Attachment TypeCoupling Screw
Voltage Rating630 V
Rated Voltage (UL)600 V
Rated Impulse Voltage6.0 kV
Operating Voltage600 V AC/DC
Current Rating16 A
Rated Current (UL)*16 A
Side 1 Contact Resistance≤ 10 mOhm
Insulation Resistance˃ 10^9 Ohm
Mating Cycles≤ 100
Ambient Temperature (Operation)*- 40 °C to + 125 °C, notice derating
Protection Degree / IP Rating**IP65, IP67
Side 1 Design StandardIEC 61076-2-111
Side 1 Pollution Degree3 acc. to IEC 60664-1
Clearance / Creepage DistanceIEC 60664-1 (2020-05)
Overvoltage CategoryIII acc. to IEC 60664-1
Note Derating* Notice derating
Protection Degree / IP Rating NoteIP Rating tested according to IEC standard using combination of a Hirschmann or Lumberg Automation connector mounted and locked
Note1. Do not connect or disconnect under load.
Product CharacteristicsTo ensure ingress protection, please check the O-ring’s position before connecting. Improperly positioned O-ring leads to ingress protection potential failure.

Face View

Pin 1black 1
Pin 2black 2
Pin 3black 3
PEgreen / yellow

Materials

Contact Base MaterialCopper Alloy (CuNi)
Side 1 Contact PlatingGold over Copper (Cu/Au)
Contact Bearer MaterialGlass-filled Polybutylene Terephthalate (PBT GF)
Contact Bearer ColorBlack
Flammability Class (Contact Bearer)UL 94 V-2
Molded Body MaterialThermoplastic Elastomer (TPE)
Molded Body ColorBlack
Flammability Class (Molded Body)UL 94 HB
Attachment MaterialCopper Alloy (CuZn)
Attachment PlatingNickel (Ni)

Circuitry

Fastening Torque (Attachment)M 12x1: (50-60) Ncm, hand-tight

Cable Data

Cable Number733
Conductor Size1.50 mm2
Number of Wires4
Minimal Bending Radius (Fixed Inst)˃ 4 x D
Minimal Bending Radius (Flexible Inst)˃ 7.5 x D
Cycles (Bending)˃ 1 Mio, max. 50 m/s2
Conductor MaterialCu
Cable Jacket MaterialPolyvinyl Chloride (PVC)
Cable Jacket ColorBlack
Cable Diameter DØ 8.0 | 0.314"
Wire Insulation MaterialPolyvinyl Chloride (PVC)
Insulated Wire DiameterØ 2.55 mm | 0.100 "
Overall Shield (Cable)Unshielded
Ambient Temperature (Fixed Installation)- 40° C to + 90° C
Ambient Temperature (Flex Installation)- 5° C to + 90° C
UL Cable TypeAWM: 2587
Flammability Class (Cable Jacket)VDE 0482-332-1-2, DIN EN 60332-1-2 / IEC 60332-1 / UL VW-1, CSA FT1
Cable CharacteristicsFlexibility: Good | Abrasion Resistance: Good | Chemical Resistance: Excellent, acids, and alkalis| Flame Retardance: VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1 | Halogen-Free: No | Mechanical Durability: Good (resists impact, tear, and flex) | Environmental Suitability: Indoor, excellent balance of performance, cost, and versatility

Approvals

UL-FileE497237
ULUL 2237; cULus

Safety & Environmental Compliance

RoHS CompliantYes

Resistances

HalogenfreeNo

Notes

Note Derating* Notice derating
Protection Degree / IP Rating NoteIP Rating tested according to IEC standard using combination of a Hirschmann or Lumberg Automation connector mounted and locked
Note1. Do not connect or disconnect under load.
Product CharacteristicsTo ensure ingress protection, please check the O-ring’s position before connecting. Improperly positioned O-ring leads to ingress protection potential failure.

Resources