Belden Store
BeldenRKWTS 5L-1021

Product Number: RKWTS 5L-1021

M12 Power Single-Ended Cordset: Female, angled, 5-pin(4+FE), L-coded, shielded, blue body, 50 V AC/60 V DC, 20 A; PUR grey cable, ca. 2,5mm2

M12 Power Single-Ended Cordset: Female, angled, 5-pin(4+FE), L-coded, shielded, blue body, 50 V AC/60 V DC, 20 A; PUR grey cable, 2.5 mm2

Availability
Global
Status
Active
Orderable items
4

Ships from and sold by A5 IT.

Part numbers

RKWTS 5L-1021 is a product family. Each item number below is a separate orderable part — colour, put-up and length differ.

Item #Item DescriptionCable LengthOrder
934850189RKWTS 5L-1021/3 M3 mOrder online
934850190RKWTS 5L-1021/5 M5 mOrder online
934850191RKWTS 5L-1021/10 M10 mOrder online
934850192RKWTS 5L-1021/15 M15 mOrder online

Specifications

Information

Product FamilyPower Connector
Side 1 Product Sub FamilyM12 Power
Connector TypeCordset, single ended
Side 1 Type of Contact/GenderSocket Contact / Female
Connector DesignMolded | M12 Female | Angled
Number of Pins5
Coding, Side 1L
Shielding TypeShielded
Attachment TypeCoupling Nut
Voltage Rating63 V
Rated Voltage (UL)63 V
Rated Impulse Voltage1.5 kV
Operating Voltage60 V AC/DC
Current Rating24 A
Rated Current (UL)*16 A (UL Certified); Product is designed to meet UL 20 A requirements, it is NOT certified yet; a UL 20 A certification process can be initiated upon special request based on a separate agreement with us.
Side 1 Contact Resistance≤ 10 mOhm
Insulation Resistance˃ 10^9 Ohm
Mating Cycles≤ 100
Ambient Temperature (Operation)*-40 °C to +125 °C, notice derating
Protection Degree / IP Rating**IP65, IP67, IP69K
Side 1 Design StandardIEC 61076-2-111
Side 1 Pollution Degree3 acc. to IEC 60664-1
Clearance / Creepage DistanceIEC 60664-1 (2020-05)
Overvoltage CategoryIII acc. to IEC 60664-1
Note Derating* Notice derating
Protection Degree / IP Rating NoteIP Rating tested according to IEC standard using combination of a Hirschmann or Lumberg Automation connector mounted and locked
Note1. Do not connect or disconnect under load.
Product CharacteristicsTo ensure ingress protection, please check the O-ring’s position before connecting. Improperly positioned O-ring leads to ingress protection potential failure.

Face View

Pin 1brown
Pin 2white
Pin 3blue
Pin 4black
FEpink

Materials

Contact Base MaterialCopper Alloy (CuNi)
Side 1 Contact PlatingGold over Copper (Cu/Au)
Contact Bearer MaterialGlass-filled Polybutylene Terephthalate (PBT GF)
Contact Bearer ColorGrey
Flammability Class (Contact Bearer)UL 94 V-2
Molded Body MaterialThermoplastic Elastomer (TPE)
Molded Body ColorBlack
Flammability Class (Molded Body)UL 94 HB
Attachment MaterialCopper Alloy (CuZn)
Attachment PlatingNickel (Ni)
Shielding MaterialCuZn, plating: Ni
O-Ring MaterialFluoroelastomer (FKM)

Circuitry

Fastening Torque (Attachment)M 12x1: (50-60) Ncm, hand-tight

Cable Data

Cable Number1021
Conductor Size2.5 mm2
Number of Wires5
Minimal Bending Radius (Fixed Inst)˃ 4 x D
Minimal Bending Radius (Flexible Inst)˃ 7.5 x D
Cycles (Bending)˃ 10 Mio, max. 50 m/s2
Cycles (Torsion)˃ 5 Mio @ ± 30 °/1 m
Conductor MaterialCu
Cable Jacket MaterialPolyurethane (PUR)
Cable Jacket ColorGrey
Cable Diameter DØ 10.6 | 0.417"
Wire Insulation MaterialPolypropylene (PP)
Insulated Wire DiameterØ 2.90 mm | 0.114"
Overall Shield (Cable)Tinned Copper Braided Screen
Ambient Temperature (Fixed Installation)- 40 °C to + 90 °C
Ambient Temperature (Flex Installation)- 30 °C to + 90 °C
Ambient Temperature (Fixed Installation short-term 100h)-40 °C to +125 °C
Ambient Temperature (Drag Chain Inst)- 20 °C to + 60 °C
UL Cable TypeAWM Style 20939
Flammability Class (Cable Jacket)VDE 0482-332-1-2, DIN EN 60332-1-2 / IEC 60332-1 / UL VW-1, CSA FT1

Approvals

UL-FileE497237
ULUL 2237; cULus

Safety & Environmental Compliance

RoHS CompliantYes

Resistances

HalogenfreeDIN VDE 0472 T.815, IEC 60754-1
Oil ResistanceHD 22.10 Appendix A, DIN EN 60811-404

Notes

Note Derating* Notice derating
Protection Degree / IP Rating NoteIP Rating tested according to IEC standard using combination of a Hirschmann or Lumberg Automation connector mounted and locked
Note1. Do not connect or disconnect under load.
Product CharacteristicsTo ensure ingress protection, please check the O-ring’s position before connecting. Improperly positioned O-ring leads to ingress protection potential failure.

Resources

Related lumberg automation m12 power high-performance solution