Belden Store
H126D00

Product Number: H126D00

H126D00 - Broadband Coax, H126D, 18 AWG Solid BC, Tri-shield, PVC Jkt

Broadband Coax, H126D, 18 AWG Solid Bare Copper Conductor, PE Insulation, Duofoil + 35% Tinned Copper Braid + Foil Shield, PVC Jacket

Availability
EMEA | Asia Pacific
Status
Discontinued
Orderable items
2

Ships from and sold by A5 IT.

Part numbers

H126D00 is a product family. Each item number below is a separate orderable part — colour, put-up and length differ.

Item #ColorPutup TypeLengthEANOrder
H126D00.00U250WhiteUnReel250 m8719605087270Order online
H126D00.00500WhiteReel500 m8719605087256Order online

Specifications

Product Overview

Suitable ApplicationsBroadband, Cable Television (CATV), RF drop cable, Over-The-Air (OTA) antennas

Product Life Cycle

Life CycleDiscontinued - the product is no longer manufactured

Construction Details

RG Type6
Outer Jacket1 Table NotesAccording to European Standard EN 50290-2-20

Conductor

No. of Elements1
Size18 AWG
StrandingSolid
Nom. Diameter1 mm
MaterialBC - Bare Copper

Insulation

MaterialPE - Polyethylene (Foam)
Nom. Insulation Diameter4.57 mm (0.180 in)

Outer Shield

LayerOuter Shield TypeMaterialCoverage
1TapeTri-Laminate (Alum+Poly+Alum)100%
2BraidTinned Copper (TC)35%
3TapeBi-Laminate (Alum+Poly)100%

Outer Jacket

MaterialPVC - Polyvinyl Chloride
Nom. Diameter6.9 mm (0.27 in)

Electrical Characteristics

Regularity of ImpedanceMin. 40 dB
Return Loss Table NotesIn each frequency band, 3 peak values up to 4 dB lower are allowed
Attenuation Table NotesMax. attenuation 10% higher

Return Loss

FrequencyMin. Return Loss
5 - 470 MHz20 dB
470 - 1000 MHz18 dB
1000 - 2000 MHz16 dB
2000 - 3000 MHz15 dB

Attenuation

FrequencyNom. Attenuation
5 MHz1.8 dB/100m
50 MHz4.7 dB/100m
100 MHz6.5 dB/100m
200 MHz9.8 dB/100m
400 MHz13 dB/100m
600 MHz16.2 dB/100m
800 MHz18.7 dB/100m
1000 MHz21.1 dB/100m
1350 MHz24.9 dB/100m
1750 MHz28.8 dB/100m
2150 MHz32.3 dB/100m
2400 MHz34.4 dB/100m
3000 MHz39.2 dB/100m

Electricals

Max. Conductor DCR23 Ohm/km (7.0 Ohm/1000ft)
Nom. Outer Shield DCR16 Ohm/km (4.9 Ohm/1000ft)
Nom. Capacitance Cond-to-Shield54 pF/m (16 pF/ft)
Nom. Characteristic Impedance75 Ohm
Nom. Velocity of Prop.82%

Screening

FrequencyMin. Screening Attenuation
30 - 1000 MHz95 dB
1000 - 2000 MHz85 dB
2000 - 3000 MHz75 dB

Mechanical Characteristics

Bulk Cable Weight46 kg/km (31 lbs/1000ft)

Temperature

Operating-40°C To +70°C
Installation-5°C To +50°C
Storage-40°C To +70°C

Bend Radius

Stationary Min.35 mm (1.4 in)

Standards and Compliance

Environmental SuitabilityIndoor - Euroclass Eca
Flammability / Reaction to FireIEC 60332-1-2
CPR ComplianceCPR Euroclass: Eca
ISO/IEC ComplianceIEC 61196
CENELEC ComplianceEN 50117-1
UK Regulation ComplianceUKCA Mark

History

Update and RevisionRevision Number: 0.314 Revision Date: 02-20-2026

Resources