Belden Store
H124A00

Product Number: H124A00

H124A00 - Broadband Coax, H124, 18 AWG Solid BC, Foil + 30% TC Braid, PVC Jkt

Broadband Coax, H124, 18 AWG Solid Bare Copper Conductor, PE Insulation, Duofoil® + 30% Tinned Copper Braid Shield, PVC Jacket

Availability
EMEA | Asia Pacific
Status
Discontinued

Ships from and sold by A5 IT.

Specifications

Product Overview

Suitable ApplicationsBroadband, Cable Television (CATV), RF drop cable, Over-The-Air (OTA) antennas

Construction Details

RG Type6
Outer Jacket1 Table NotesAccording to EN 50290-2-20

Conductor

No. of Elements1
Size18 AWG
StrandingSolid
Nom. Diameter1 mm
MaterialBC - Bare Copper

Insulation

ElementInsulated Conductor
MaterialPE - Polyethylene (Foam)
Nom. Insulation Diameter4.4 mm (0.17 in)

Outer Shield

LayerOuter Shield TypeMaterialCoverage
1TapeTri-Laminate (Alum+Poly+Alum)100%
2BraidTinned Copper (TC)30%

Outer Jacket

MaterialPVC - Polyvinyl Chloride
Nom. Diameter5.9 mm

Electrical Characteristics

Regularity of ImpedanceMin. 40 dB
Return Loss Table NotesIn each frequency band, 3 peak values up to 4 dB lower are allowed
Attenuation Table NotesMax. attenuation 10% higher

Return Loss

FrequencyMin. Return Loss
5 - 30 MHz23 dB
30 - 470 MHz23 dB
470 - 862 MHz20 dB
862 - 2400 MHz18 dB

Attenuation

FrequencyNom. Attenuation
5 MHz2 dB/100m
50 MHz4.5 dB/100m
100 MHz6.4 dB/100m
200 MHz9.2 dB/100m
400 MHz13.3 dB/100m
600 MHz16.5 dB/100m
800 MHz19.3 dB/100m
1000 MHz21.8 dB/100m
1350 MHz25.7 dB/100m
1750 MHz29.7 dB/100m
2150 MHz33.4 dB/100m
2400 MHz35.6 dB/100m

Electricals

Max. Conductor DCR23 Ohm/km (7.0 Ohm/1000ft)
Nom. Outer Shield DCR35 Ohm/km (11 Ohm/1000ft)
Nom. Capacitance Cond-to-Shield53 pF/m (16 pF/ft)
Nom. Characteristic Impedance75 Ohm
Nom. Velocity of Prop.84%

Screening

Frequency30 - 1000 MHz
Min. Screening Attenuation75 dB

Mechanical Characteristics

Max. Pull Tension55 N (12 lbf)
Bulk Cable Weight32 kg/km

Temperature

Operating-15°C To +70°C
Installation-5°C To +50°C
Storage-15°C To +70°C

Bend Radius

Stationary Min.30 mm (1.2 in)

Standards and Compliance

Environmental SuitabilityIndoor/Outdoor - Euroclass Eca
Flammability / Reaction to FireIEC 60332-1-2
CPR ComplianceCPR Euroclass: Eca
ISO/IEC ComplianceIEC 61196
CENELEC ComplianceEN 50117-1
European Directive ComplianceEU CE Mark
UK Regulation ComplianceUKCA Mark

History

Update and RevisionRevision Number: 0.208 Revision Date: 02-20-2026

Resources