CX6C2 - Broadband Coax 6, 14 AWG Solid BC, Foil + 60% BC Braid, LSZH Jkt
Broadband Coax 6, 14 AWG Solid Bare Copper Conductor, PE Insulation, Copper Foil + 60% Bare Copper Braid Shield, LSZH Jacket.
- Availability
- EMEA | Asia Pacific
- Status
- Active
- Orderable items
- 2
Part numbers
CX6C2 is a product family. Each item number below is a separate orderable part — colour, put-up and length differ.
| Item # | Color | Putup Type | Length | EAN | Order |
|---|---|---|---|---|---|
| CX6C2.019999 | Green | Reel | 799 m | 8719605195869 | Order online |
| CX6C2.011000 | Green | Reel | 1,000 m | 8719605195845 | Order online |
Specifications
Product Overview
| Suitable Applications | Broadband, Cable Television (CATV), RF drop cable, Over-The-Air (OTA) antennas |
|---|
Construction Details
| Insulation Table Notes | Centricity min. 85% |
|---|
Conductor
| No. of Elements | 1 |
|---|---|
| Size | 14 AWG |
| Stranding | Solid |
| Nom. Diameter | 1.61 mm |
| Material | BC - Bare Copper |
Insulation
| Element | Insulated Conductor |
|---|---|
| Material | PE - Polyethylene (Foam) |
| Nom. Insulation Diameter | 7.55 mm (0.297 in) |
Outer Shield
| Layer | Outer Shield Type | Material | Coverage |
|---|---|---|---|
| 1 | Tape | Bi-Laminate (Bare Copper+Poly) | 100% |
| 2 | Braid | Bare Copper (BC) | 70% |
Outer Jacket
| Material | LSZH - Low Smoke Zero Halogen (Flame Retardant) |
|---|---|
| Nom. Diameter | 11.1 |
Electrical Characteristics
| Regularity of Impedance | Min. 40 dB |
|---|---|
| Attenuation Table Notes | Max. attenuation 10% higher |
Return Loss
| Frequency | Min. Return Loss |
|---|---|
| 5 - 470 MHz | 26 dB |
| 470 - 1000 MHz | 23 dB |
| 1000 - 2000 MHz | 18 dB |
| 2000 - 3000 MHz | 16 dB |
Attenuation
| Frequency | Nom. Attenuation |
|---|---|
| 5 MHz | 1.2 dB/100m |
| 50 MHz | 2.7 dB/100m |
| 100 MHz | 3.8 dB/100m |
| 200 MHz | 5.4 dB/100m |
| 400 MHz | 7.8 dB/100m |
| 600 MHz | 9.7 dB/100m |
| 800 MHz | 11.3 dB/100m |
| 1000 MHz | 12.8 dB/100m |
| 1350 MHz | 14.9 dB/100m |
| 1750 MHz | 17.3 dB/100m |
| 2150 MHz | 19.4 dB/100m |
| 2400 MHz | 20.6 dB/100m |
| 3000 MHz | 23.5 dB/100m |
| 4000 MHz | 27.8 dB/100m |
Electricals
| Max. Conductor DCR | 8.7 Ohm/km (2.7 Ohm/1000ft) |
|---|---|
| Nom. Outer Shield DCR | 6.3 Ohm/km (1.9 Ohm/1000ft) |
| Nom. Capacitance Cond-to-Shield | 55 pF/m (17 pF/ft) |
| Nom. Characteristic Impedance | 75 Ohm |
| Nom. Velocity of Prop. | 81% |
Screening
| Frequency | Min. Screening Attenuation |
|---|---|
| 30 - 1000 MHz | 80 dB |
| 1000 - 2000 MHz | 75 dB |
| 2000 - 3000 MHz | 70 dB |
| 3000 - 4000 MHz | 65 dB |
Mechanical Characteristics
| Max. Pull Tension | 300 N (67 lbf) |
|---|
Temperature
| Operating | -25°C - +70°C |
|---|---|
| Installation | -5°C To +50°C |
| Storage | -25°C - +70°C |
Bend Radius
| Stationary Min. | 120 mm (4.7 in) |
|---|
Standards and Compliance
| Environmental Suitability | Indoor/Outdoor - Euroclass Dca |
|---|---|
| Flammability / Reaction to Fire | IEC 60332-1-2 |
| CPR Compliance | CPR Euroclass: Dca-s1,d2,a1 |
| CENELEC Compliance | EN 50117-1, EN 50117-11-1, EN 50290-2-20 |
| European Halogen Free Standards | IEC 62821-1 Halogen Free Compliance = Yes, IEC 60754-1 - Halogen Amount = Zero, IEC 60754-2 - Halogen Acid Gas Amount - Max. Conductivity = 2.5 μS/mm, IEC 60754-2 - Halogen Acid Gas Amount - Min. pH = 4.3 |
| European Directive Compliance | EU CE Mark |
| UK Regulation Compliance | UKCA Mark |
History
| Update and Revision | Revision Number: 0.70 Revision Date: 02-20-2026 |
|---|
Resources
Related catv cable

1152A
Broadband Coax, Series 6, 18 AWG Solid BCCS, Quad Shield, FEP Jkt, CMP
18 AWG · BCCS - Bare Copper Covered Steel · FEP - Fluorinated Ethylene Propylene (Foam) · FEP - Fluorinated Ethylene Propylene

1153A
CATV Video, RG11 Type, 14 AWG BCCS, Quad Shield (Foil + 60% Braid + Foil + 40% Braid), CMP
14 · BCCS - Bare Copper Covered Steel · FEP - Fluorinated Ethylene Propylene (Foam) · FEP - Fluorinated Ethylene Propylene

1189A
Broadband Coax, Series 6, 18 AWG Solid BCCS, Quad Shield, PVC Jkt, CM
18 AWG · BCCS - Bare Copper Covered Steel · PE - Polyethylene (Foam) · PVC - Polyvinyl Chloride

1189AP
Broadband Coax, Series 6, 18 AWG Solid BCCS, Quad Shield, Flamarrest® Jkt, CMP
18 AWG · BCCS - Bare Copper Covered Steel · FEP - Fluorinated Ethylene Propylene (Foam) · PVC - Polyvinyl Chloride