Belden Store
7916AP

Product Number: 7916AP

Broadband Coax, Series 6, 18 AWG Solid BC, Quad Shield, Flamarrest® Jkt, CMP

Broadband Coax, Series 6, 18 AWG Solid Bare Copper Conductor, FEP Insulation, Foil + 60% Aluminum Braid + Foil + 40% Aluminum Braid Shield, Flamarrest® Jacket, CMP

Availability
Global
Status
Active
Orderable items
1

Ships from and sold by A5 IT.

Part numbers

7916AP is a product family. Each item number below is a separate orderable part — colour, put-up and length differ.

Item #ColorPutup TypeLengthUPCFootnoteOrder
7916AP 8771000NaturalReel1,000 ft612825191131COrder online

Specifications

Product Overview

Suitable ApplicationsBroadband, Cable Television (CATV), RF drop cable, Direct Broadcast Satellite (DBS), Over-The-Air (OTA) antennas

Construction Details

Series Type6
Overall Cable Diameter (Nominal)0.248 in (6.30 mm)

Conductor

Size18 AWG
StrandingSolid
Nom. Diameter0.040 in
MaterialBC - Bare Copper

Insulation

MaterialFEP - Fluorinated Ethylene Propylene (Foam)
Nom. Insulation Diameter0.170 in (4.32 mm)
Color CodeWhite

Outer Shield

LayerOuter Shield TypeMaterialMaterial Trade NameCoverage
1TapeTri-Laminate (Alum+Poly+Alum)Duobond® II100%
2BraidAluminum60%
3TapeTri-Laminate (Alum+Poly+Alum)Duofoil®100%
4BraidAluminum40%

Outer Jacket

MaterialPVC - Polyvinyl Chloride
Nom. Diameter0.248 in (6.30 mm)

Electrical Characteristics

Return Loss

FrequencyMin. Structural Return Loss
5 - 1000 MHz20 dB
1000 - 2250 MHz15 dB
2250 - 3000 MHz10 dB

Attenuation

FrequencyNom. Attenuation
1 MHz0.3 dB/100ft
10 MHz0.7 dB/100ft
50 MHz1.6 dB/100ft
100 MHz2.1 dB/100ft
200 MHz2.9 dB/100ft
400 MHz4.3 dB/100ft
700 MHz6.1 dB/100ft
750 MHz6.4 dB/100ft
900 MHz7.1 dB/100ft
1000 MHz8.2 dB/100ft

Electricals

Nom. Conductor DCR6.4 Ohm/1000ft
Nom. Outer Shield DCR4.8 Ohm/1000ft (16 Ohm/km)
Nom. Capacitance Cond-to-Shield16.3 pF/ft (53.5 pF/m)
Nom. Characteristic Impedance75 Ohm
Nom. Velocity of Prop.83%

Voltage

UL Voltage Rating300 V (CMP)

Mechanical Characteristics

Max. Pull Tension137 lbs (62.1 kg)
Bulk Cable Weight39 lbs/1000ft

Temperature

UL Temperature75°C
Operating-20°C to +75°C

Bend Radius

Installation Min.2.5 in (64 mm)

Standards and Compliance

Environmental SuitabilityIndoor - Plenum, Indoor
SustainabilityCA Prop 65
Flammability / Reaction to FireNFPA 262
CEC / C(UL) ComplianceCMP.
European Directive ComplianceEU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), REACH, EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE)
APAC ComplianceChina RoHS II (GB/T 26572-2011)
Non-Plenum Number7916A

History

Update and RevisionRevision Number: 0.476 Revision Date: 02-20-2026
FootnoteC - CRATE REEL PUT-UP.

Resources

Related catv cable