DBS Cable, Dual RG6, 18 AWG BCCS, Foil + Braid, CM
Series 6 (RG6/U type Dual Coax), 18 AWG solid .040" bare copper-covered steel conductor, gas-injected foam polyethylene insulation, Duobond® II, Al. braid shield (60% coverage), PVC jacket.
- Availability
- Global
- Status
- Discontinued
- Orderable items
- 1
Part numbers
1841A is a product family. Each item number below is a separate orderable part — colour, put-up and length differ.
| Item # | Color | Putup Type | Length | UPC | Footnote | Order |
|---|---|---|---|---|---|---|
| 1841A 0101000 | Black | Reel | 1,000 ft | 612825124351 | C | Order online |
Specifications
Product Life Cycle
| Life Cycle | Discontinued - the product is no longer manufactured |
|---|---|
| Discontinuation Announcement Date | 2024-07-08 |
Construction Details
| RG Type | 6 |
|---|---|
| Series Type | 6 |
| Insulation Table Notes | Gas Injected |
Conductor
| Size | 18 |
|---|---|
| Stranding | Solid |
| Nom. Diameter | 0.04 in |
| Material | BCCS - Bare Copper Covered Steel |
Insulation
| Material | PE - Polyethylene (Foam) |
|---|---|
| Nom. Insulation Diameter | 0.18 in (4.6 mm) |
Outer Shield
| Layer | Outer Shield Type | Material | Material Trade Name | Coverage |
|---|---|---|---|---|
| 1 | Tape | Tri-Laminate (Alum+Poly+Alum) | Duofoil® | 100% |
| 2 | Braid | Aluminum | 60% |
Outer Jacket
| Material | PVC - Polyvinyl Chloride |
|---|---|
| Nom. Diameter | 0.273 x 0.595 in |
Electrical Characteristics
Return Loss
| Frequency | Min. Structural Return Loss |
|---|---|
| 950 - 2250 MHz | 15 dB |
| 2250 - 3000 MHz | 10 dB |
Attenuation
| Frequency | Nom. Attenuation | Max. Attenuation |
|---|---|---|
| 5 MHz | 0.5 dB/100ft | 0.58 dB/100ft |
| 55 MHz | 1.4 dB/100ft | 1.6 dB/100ft |
| 211 MHz | 2.6 dB/100ft | 3.05 dB/100ft |
| 500 MHz | 4.1 dB/100ft | 4.66 dB/100ft |
| 750 MHz | 5.1 dB/100ft | 5.65 dB/100ft |
| 862 MHz | 5.5 dB/100ft | 6.1 dB/100ft |
| 1000 MHz | 6 dB/100ft | 6.55 dB/100ft |
| 1450 MHz | 7.8 dB/100ft | 8 dB/100ft |
| 1800 MHz | 8.6 dB/100ft | 8.8 dB/100ft |
| 2250 MHz | 9.8 dB/100ft | 10 dB/100ft |
| 3000 MHz | 11.3 dB/100ft | 11.9 dB/100ft |
Electricals
| Nom. Conductor DCR | 28 Ohm/1000ft (92 Ohm/km) |
|---|---|
| Nom. Outer Shield DCR | 9 Ohm/1000ft (30 Ohm/km) |
| Nom. Capacitance Cond-to-Shield | 16.2 pF/ft (53.1 pF/m) |
| Nom. Characteristic Impedance | 75 Ohm |
| Nom. Velocity of Prop. | 83% |
Voltage
| Voltage Rating | 350 V RMS |
|---|
Mechanical Characteristics
| Max. Pull Tension | 252 lbs (114 kg) |
|---|---|
| Bulk Cable Weight | 56 lbs/1000ft (83 kg/km) |
Temperature
| Operating | -40°C To +80°C |
|---|
Standards and Compliance
| Environmental Suitability | Indoor (Not Riser or Plenum), Indoor |
|---|---|
| Flammability / Reaction to Fire | UL1685 UL Loading |
| CPR Compliance | CPR Euroclass: Eca |
| NEC / UL Compliance | CATV, CM |
| CEC / C(UL) Compliance | CM. |
| European Directive Compliance | EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| UK Regulation Compliance | UKCA Mark |
| APAC Compliance | China RoHS II (GB/T 26572-2011) |
History
| Update and Revision | Revision Number: 0.437 Revision Date: 07-30-2026 |
|---|---|
| Footnote | C - CRATE REEL PUT-UP. |
Resources
Related catv cable

1152A
Broadband Coax, Series 6, 18 AWG Solid BCCS, Quad Shield, FEP Jkt, CMP
18 AWG · BCCS - Bare Copper Covered Steel · FEP - Fluorinated Ethylene Propylene (Foam) · FEP - Fluorinated Ethylene Propylene

1153A
CATV Video, RG11 Type, 14 AWG BCCS, Quad Shield (Foil + 60% Braid + Foil + 40% Braid), CMP
14 · BCCS - Bare Copper Covered Steel · FEP - Fluorinated Ethylene Propylene (Foam) · FEP - Fluorinated Ethylene Propylene

1189A
Broadband Coax, Series 6, 18 AWG Solid BCCS, Quad Shield, PVC Jkt, CM
18 AWG · BCCS - Bare Copper Covered Steel · PE - Polyethylene (Foam) · PVC - Polyvinyl Chloride

1189AP
Broadband Coax, Series 6, 18 AWG Solid BCCS, Quad Shield, Flamarrest® Jkt, CMP
18 AWG · BCCS - Bare Copper Covered Steel · FEP - Fluorinated Ethylene Propylene (Foam) · PVC - Polyvinyl Chloride