Belden Store
1839A

Product Number: 1839A

DBS Cable, RG6, 18 AWG BCCS, Foil + Braid, Messenger

Series 6, 18 AWG solid .040" bare copper-covered steel conductor, gas-injected foam polyethylene insulation, Duobond® II, Al. braid shield (60% coverage), .045" bare copper-covered steel static ground, PVC jacket.

Availability
Global
Status
Discontinued
Orderable items
1

Ships from and sold by A5 IT.

Part numbers

1839A is a product family. Each item number below is a separate orderable part — colour, put-up and length differ.

Item #ColorPutup TypeLengthUPCFootnoteOrder
1839A 0101000BlackReel1,000 ft612825124276COrder online

Specifications

Product Life Cycle

Life CycleDiscontinued - the product is no longer manufactured
Discontinuation Announcement Date2024-07-08

Construction Details

RG Type6
Series Type6
Insulation Table NotesGas Injected

Conductor

Size18
StrandingSolid
Nom. Diameter0.04 in
MaterialBCCS - Bare Copper Covered Steel

Insulation

MaterialPE - Polyethylene (Foam)
Nom. Insulation Diameter0.18 in (4.6 mm)

Outer Shield

LayerOuter Shield TypeMaterialMaterial Trade NameCoverage
1TapeTri-Laminate (Alum+Poly+Alum)Duofoil®100%
2BraidAluminum60%

Outer Jacket

MaterialPVC - Polyvinyl Chloride
Nom. Diameter0.27 x 0.405 in

Electrical Characteristics

Return Loss

FrequencyMin. Structural Return Loss
950 - 2250 MHz15 dB
2250 - 3000 MHz10 dB

Attenuation

FrequencyNom. AttenuationMax. Attenuation
5 MHz0.5 dB/100ft0.58 dB/100ft
55 MHz1.4 dB/100ft1.6 dB/100ft
211 MHz2.6 dB/100ft3.05 dB/100ft
500 MHz4.1 dB/100ft4.66 dB/100ft
750 MHz5.1 dB/100ft5.65 dB/100ft
862 MHz5.5 dB/100ft6.1 dB/100ft
1000 MHz6 dB/100ft6.55 dB/100ft
1450 MHz7.8 dB/100ft8 dB/100ft
1800 MHz8.6 dB/100ft8.8 dB/100ft
2250 MHz9.8 dB/100ft10 dB/100ft
3000 MHz11.3 dB/100ft11.9 dB/100ft

Electricals

Nom. Conductor DCR28 Ohm/1000ft (92 Ohm/km)
Nom. Outer Shield DCR9 Ohm/1000ft (30 Ohm/km)
Nom. Capacitance Cond-to-Shield16.2 pF/ft (53.1 pF/m)
Nom. Characteristic Impedance75 Ohm
Nom. Velocity of Prop.83%

Voltage

Voltage Rating350 V RMS

Mechanical Characteristics

Max. Pull Tension160 lbs (73 kg)
Bulk Cable Weight41 lbs/1000ft (61 kg/km)

Temperature

Operating-40°C To +80°C

Standards and Compliance

Environmental SuitabilityIndoor (Not Riser or Plenum), Indoor
European Directive ComplianceEU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE)
APAC ComplianceChina RoHS II (GB/T 26572-2011)

History

Update and RevisionRevision Number: 0.390 Revision Date: 07-30-2026
FootnoteC - CRATE REEL PUT-UP.

Resources

Related catv cable