Belden Store
1829A

Product Number: 1829A

Broadband Coax, Series 6, 18 AWG Solid BCCS, Foil + 60% AL Braid, PVC Jkt, CM

Broadband Coax, Series 6, 18 AWG Solid Bare Copper Covered Steel Conductor, PE Insulation, Foil + 60% Aluminum Braid Shield, PVC Jacket, CM

Availability
Global
Status
Active
Orderable items
1

Ships from and sold by A5 IT.

Part numbers

1829A is a product family. Each item number below is a separate orderable part — colour, put-up and length differ.

Item #ColorPutup TypeLengthUPCOrder
1829A 010U1000BlackUnReel1,000 ft612825123903Order online

Specifications

Product Overview

Suitable ApplicationsBroadband, Cable Television (CATV), RF drop cable, Direct Broadcast Satellite (DBS), Over-The-Air (OTA) antennas

Construction Details

Series Type6
Overall Cable Diameter (Nominal)0.270 in (6.86 mm)

Conductor

Size18 AWG
StrandingSolid
Nom. Diameter0.040 in
MaterialBCCS - Bare Copper Covered Steel

Insulation

MaterialPE - Polyethylene (Foam)
Nom. Insulation Diameter0.180 in (4.57 mm)
Color CodeWhite

Outer Shield

LayerOuter Shield TypeMaterialMaterial Trade NameCoverage
1TapeTri-Laminate (Alum+Poly+Alum)Duobond® II100%
2BraidAluminum60%

Outer Jacket

MaterialPVC - Polyvinyl Chloride
Nom. Diameter0.270 in (6.86 mm)

Electrical Characteristics

Return Loss

FrequencyMin. Structural Return Loss
950 - 2250 MHz15 dB
2250 - 3000 MHz10 dB

Attenuation

FrequencyMax. Attenuation
5 MHz0.58 dB/100ft
55 MHz1.60 dB/100ft
211 MHz3.05 dB/100ft
250 MHz3.30 dB/100ft
270 MHz3.37 dB/100ft
300 MHz3.55 dB/100ft
330 MHz3.74 dB/100ft
350 MHz3.85 dB/100ft
400 MHz4.15 dB/100ft
450 MHz4.40 dB/100ft
500 MHz4.66 dB/100ft
550 MHz4.90 dB/100ft
600 MHz5.10 dB/100ft
750 MHz5.65 dB/100ft
870 MHz6.11 dB/100ft
1000 MHz6.55 dB/100ft

Electricals

Nom. Conductor DCR28 Ohm/1000ft
Nom. Outer Shield DCR9 Ohm/1000ft (30 Ohm/km)
Nom. Capacitance Cond-to-Shield16.2 pF/ft (53.1 pF/m)
Nom. Characteristic Impedance75 Ohm
Nom. Velocity of Prop.83%

Voltage

UL Voltage Rating300 V (CM)

Mechanical Characteristics

Max. Pull Tension150 lbs (68 kg)
Bulk Cable Weight27 lbs/1000ft

Temperature

Operating-40°C to +75°C

Bend Radius

Installation Min.2.7 in (69 mm)

Standards and Compliance

Environmental SuitabilityIndoor (Not Riser or Plenum), Indoor, Aerial - Black only, When supported by messenger wire
SustainabilityCA Prop 65
Flammability / Reaction to FireUL1685 UL Loading
CPR ComplianceCPR Euroclass: Eca
NEC / UL ComplianceCM, CATV
CEC / C(UL) ComplianceCM.
European Directive ComplianceEU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), REACH, EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE)
UK Regulation ComplianceUKCA Mark
APAC ComplianceChina RoHS II (GB/T 26572-2011)
Other Standard Compliance(s)ANSI/SCTE 74

History

Update and RevisionRevision Number: 0.477 Revision Date: 02-20-2026
FootnoteZ - FINAL PUT-UP MAY VARY (= OR -) 10% FOR SPOOLS OR REELS AND (+ OR -) 5% FOR UNREEL CARTONS FROM LENGTH SHOWN., C - CRATE REEL PUT-UP.

Resources