VFD, 3C #8 Str BC XLPE Ins + #10 Symm. Seg. Gnd (3 of #14) Str BC, CTS, Blk PVC Jkt, 2000V TC-ER 90C Dry/Wet 1000V CSA AWM I/II A/B
Belden Basics VFD, 3 Conductor 8AWG (7x16) Bare Copper XLPE Insulation M4 Color Code + 10AWG Symmetrical Segmented Ground (3 of 14AWG) Bare Copper Stranded, Overall Dual Copper Tapes Helically Applied Shield, Black PVC Outer Jacket, 2000V TC-ER 90C Dry/Wet 1000V CSA AWM I/II A/B SUN RES DIR BUR Oil Resistant
- Availability
- Global
- Status
- Active
- Orderable items
- 2
Part numbers
29724C is a product family. Each item number below is a separate orderable part — colour, put-up and length differ.
| Item # | Putup Type | UPC | Order |
|---|---|---|---|
| 29724C 0102500 | Reel | 612825445494 | Order online |
| 29724C 0105000 | Reel | 612825445500 | Order online |
Specifications
Information
| Put-Up Type | Reel |
|---|---|
| Update and Revision | Revision Number: 0.153 Revision Date: 04-01-2026 |
Product Overview
| Suitable Applications | Variable Frequency Drives (VFD); AC Motor and Drive Systems; High voltage requirements |
|---|
Construction Details
| Overall Cable Diameter (Nominal) | 0.794 in (20.2 mm) |
|---|
Conductor
| Element | No. of Elements | Size | Stranding | Material | Notes |
|---|---|---|---|---|---|
| Conductor(s) | 3 | 8 AWG | 7x16 | BC - Bare Copper | ASTM B3 Copper B8 Class B Stranding |
| Ground | 3 | 14 AWG | 7x22 | BC - Bare Copper | Segmented Grounds |
Insulation
| Element | Material | Nom. Thickness | Nom. Insulation Diameter | Color Code |
|---|---|---|---|---|
| Conductor(s) | XLPE - Cross-Linked Polyethylene (Thermoset) | 0.072 in (1.8 mm) | 0.286 in (7.26 mm) | Black and Numbered |
| Ground | No Insulation |
Outer Shield
| Shield Type | Material | Coverage |
|---|---|---|
| Helical Tape | Bare Copper (BC) | 100% |
| Helical Tape | Bare Copper (BC) | 100% |
Outer Jacket
| Material | PVC - Polyvinyl Chloride |
|---|---|
| Nom. Thickness | 0.083 in (2.1 mm) |
| Nom. Diameter | 0.794 in (20.2 mm) |
| Ripcord | Yes |
Electrical Characteristics
Electricals
| Element | Conductor(s) |
|---|---|
| Nom. Conductor DCR | 0.564 Ohm/1000ft (1.85 Ohm/km) |
| Nom. Capacitance Cond-to-Cond | 21 pF/ft (69 pF/m) |
| Nom. Capacitance Cond-to-Other (Conds + Shield) | 38 pF/ft (120 pF/m) |
| Nom. Characteristic Impedence | 90 Ohm |
| Nom. Velocity of Prop. | 55% |
| Max. Current | 55 Amps per Conductor at 30oC |
Voltage
| UL Voltage Rating | 2000 V (TC), 1000 V (CSA AWM I/II A/B) |
|---|
Mechanical Characteristics
| Max. Pull Tension | 819 lbs (371 kg) |
|---|---|
| Bulk Cable Weight | 444 lbs/1000ft (661 kg/km) |
Temperature
| UL Temperature | 90°C Dry, 90°C Wet |
|---|---|
| Operating | -40°C To +90°C |
Bend Radius
| Stationary Min. | 9.5 in (240 mm) |
|---|---|
| Installation Min. | 9.5 in (240 mm) |
Standards and Compliance
| Environmental Suitability | Indoor, Outdoor, Sunlight Resistance, Oil Resistance, Burial |
|---|---|
| Sustainability | CA Prop 65 |
| Flammability / Reaction to Fire | UL1685 UL Loading, 1202, 383 Vertical Tray Flame Test (70,000 BTU) |
| NEC / UL Compliance | Article 336, TC-ER, RHW-2 |
| AWM Compliance | I/II A/B |
| ICEA Compliance | S-95-658 |
| European Directive Compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| APAC Compliance | China RoHS II (GB/T 26572-2011) |
| Other Standard Compliance(s) | P-07-KA070003-MSHA |
History
| Update and Revision | Revision Number: 0.153 Revision Date: 04-01-2026 |
|---|
Resources
Related vfd cable

29500
VFD 300% Gnd, 3C+G #16 Str TC, XLPE Ins+PVC Gnd, OS+TC Brd w/#16 TC Ground/Drain, Blk PVC Jkt, 600V TC-ER 90C Dry/Wet 1000V Flexible Motor Supply Cable WTTC
PVC - Polyvinyl Chloride · 600 V RMS (Type TC) (TC-ER, WTTC, UL Flexible Motor Supply Cable), 600 V (C(UL) CIC TC) · 90°C Dry, 90°C Wet

29500T
VFD 300% Gnd, 3C+G #16 Str TC, XLPE Ins+PVC Grd, OS+TC Brd w/#16 TC Drain, Blk LSZH Jkt, 600V TC-ER 90C Dry/Wet 1000V Flexible Motor Supply Cable WTTC
LSZH - Low Smoke Zero Halogen (Flame Retardant) · 1000 V (TC, WTTC, UL Flexible Motor Supply Cable) · 90°C Dry, 90°C Wet

29501
VFD 300% Gnd, 3C+G #14 Str TC, XLPE Ins+PVC Gnd, OS+TC Brd w/#14 TC Ground/Drain, Blk PVC Jkt, 600/1000V TC-ER 90C Dry/Wet 1000V Flexible Motor Supply Cable WTTC
PVC - Polyvinyl Chloride · 1000 V (TC-ER, WTTC,UL44, UL Flexible Motor Supply Cable), 600 V (C(UL) CIC TC) · 90°C Dry, 90°C Wet

29501T
VFD 300% Gnd, 3C+G #14 Str TC, XLPE Ins+PVC Grd, OS+TC Brd w/#14 TC Drain, Blk LSZH Jkt, 600/1000V TC-ER 90C Dry/Wet 1000V Flexible Motor Supply Cable WTTC
LSZH - Low Smoke Zero Halogen (Flame Retardant) · 1000 V (TC, WTTC, UL Flexible Motor Supply Cable) · 90°C Dry, 90°C Wet