Product Number: 29560C

VFD, 3C #3/0 Str BC XLPE Ins + #3 Symm. Seg. Gnd (3 of #8) Str BC, CTS, Blk PVC Jkt, 1000V CSA TC C22.2 #230 C22.2 #38

Belden Basics CSA VFD, 3 Conductor 3/0AWG (19x11) Bare Copper XLPE Insulation M4 Color Code + 3AWG Symmetrical Segmented Ground (3 of 8AWG) Bare Copper Stranded, Overall Dual Copper Tapes Helically Applied Shield, Black PVC Outer Jacket, 1000V CSA TC C22.2 #230 C22.2 #38 SUN RES DIR BUR Oil Resistance

Availability
Global
Status
Active

Ships from and sold by A5 IT.

Specifications

Product Overview

Suitable ApplicationsVariable Frequency Drives (VFD); AC Motor and Drive Systems; Specific ratings for applications in Canada

Construction Details

Outer Shield Table NotesSeparator-Polypropylene Tape
Overall Cable Diameter (Nominal)1.553 in (39.45 mm)

Conductor

ElementNo. of ElementsSizeStrandingMaterialNotes
Conductor(s)33/0 AWG19x10BC - Bare Copper
Ground Wire38 AWG7x16BC - Bare CopperSegmented Grounds

Insulation

ElementMaterialNom. ThicknessNom. Insulation DiameterColor Code
Conductor(s)XLPE - Cross-Linked Polyethylene (Thermoset)0.080 in (2.0 mm)0.622 in (15.8 mm)ICEA Chart M4
Ground WireNo Insulation

Outer Shield

Shield TypeMaterialCoverage
TapePolypropylene Foam100%
Helical TapeBare Copper (BC)100%
Helical TapeBare Copper (BC)100%

Outer Jacket

MaterialPVC - Polyvinyl Chloride
Nom. Thickness0.093 in (2.4 mm)
Nom. Diameter1.553 in (39.45 mm)
RipcordYes

Electrical Characteristics

Electricals

ElementNom. Conductor DCRNom. Capacitance Cond-to-CondNom. Capacitance Cond-to-Other (Conds + Shield)Nom. Characteristic ImpedenceNom. Velocity of Prop.Max. Current
Conductor(s)0.065 Ohm/1000ft33 pF/ft (110 pF/m)60 pF/ft (200 pF/m)56 Ohm55%225 Amps per Conductor at 30oC
0.68 Ohm/1000ft (2.2 Ohm/km)

Voltage

UL Voltage Rating1000 V (CSA TC)
Voltage Rating1000 V (CSA TC)

Mechanical Characteristics

Max. Pull Tension6716 lbs (3046 kg)
Bulk Cable Weight2273 lbs/1000ft

Temperature

UL Temperature90°C Dry, 90°C Wet
Operating-40°C To +90°C

Bend Radius

Stationary Min.18.7 in (475 mm)
Installation Min.18.7 in (475 mm)

Standards and Compliance

Environmental SuitabilityIndoor, Outdoor, Sunlight Resistance, Burial
SustainabilityCA Prop 65
Flammability / Reaction to FireUL 1685 UL Loading
CEC / C(UL) ComplianceCSA TC.
ICEA ComplianceS-95-658
European Directive ComplianceEU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE)
APAC ComplianceChina RoHS II (GB/T 26572-2011)