Belden Store
29528C

Product Number: 29528C

VFD, 3C #1 Str BC XLPE Ins + #5 Symm. Seg. Gnd (3 of #10) Str BC, CTS, Blk PVC Jkt, 600/1000V TC-ER 90C Dry/Wet 1000V

Belden Basics VFD, 3 Conductor 1AWG (19x14) Bare Copper XLPE Insulation M4 Color Code + 5AWG Symmetrical Segmented Ground (3 of 10AWG) Bare Copper Stranded in Continuous Contact with Overall Dual Copper Tape Helically Applied Shield, Black PVC Outer Jacket, 600/1000V TC-ER 90C Dry/Wet 1000V SUN RES DIR BUR Oil Resistant

Availability
Global
Status
Active
Orderable items
1

Ships from and sold by A5 IT.

Part numbers

29528C is a product family. Each item number below is a separate orderable part — colour, put-up and length differ.

Item #ColorPutup TypeLengthUPCOrder
29528C 0103000BlackReel3,000 ft612825137894Order online

Specifications

Information

Put-Up TypeReel
Update and RevisionRevision Number: 0.721 Revision Date: 04-01-2026

Product Overview

Suitable ApplicationsVariable Frequency Drives (VFD); AC Motor and Drive Systems; Class 1 Division 2 Hazardous Locations

Construction Details

Overall Cable Diameter (Nominal)1.121 in (28.47 mm)

Conductor

ElementNo. of ElementsSizeStrandingMaterialNotes
Conductor(s)31 AWG19x14BC - Bare CopperASTM B3 Copper B8 Class B Stranding
Segmented Ground Wire310 AWG7x18BC - Bare CopperSegmented Ground (3 Total 5AWG)

Insulation

ElementMaterialNom. ThicknessNom. Insulation DiameterColor Code
Conductor(s)XLPE - Cross-Linked Polyethylene (Thermoset)0.057 in (1.4 mm)0.438 in (11.1 mm)ICEA Chart M4
Ground WireNo Insulation

Outer Shield

Shield TypeMaterialCoverage
Helical TapeBare Copper (BC)100%
Helical TapeBare Copper (BC)100%

Outer Jacket

MaterialPVC - Polyvinyl Chloride
Nom. Thickness0.083 in (2.1 mm)
Nom. Diameter1.121 in (28.47 mm)
RipcordYes

Electrical Characteristics

Nom Outer Shield DCR1.48 Ohm/1000ft (4.86 Ohm/km)

Electricals

ElementNom. Conductor DCRNom. Capacitance Cond-to-CondNom. Capacitance Cond-to-Other (Conds + Shield)Nom. Characteristic ImpedenceNom. InductanceNom. Velocity of Prop.Max. Current
Conductor(s)0.13 Ohm/1000ft (0.43 Ohm/km)35 pF/ft (110 pF/m)66 pF/ft (220 pF/m)36 Ohm0.146 μH/ft (0.479 μH/m)55%145 Amps per Conductor at 30oC (per NEC)
0.30 Ohm/1000ft (0.98 Ohm/km)

Voltage

UL Voltage Rating1000 V (TC-ER)

Mechanical Characteristics

Max. Pull Tension3637.2 lbs (1649.8 kg)
Bulk Cable Weight1162 lbs/1000ft (1729 kg/km)

Temperature

UL Temperature90°C Dry, 90°C Wet
Operating-40°C To +90°C

Bend Radius

Stationary Min.13.5 in (343 mm)
Installation Min.13.5 in (343 mm)

Standards and Compliance

Environmental SuitabilityIndoor, Outdoor, Sunlight Resistance, Burial
SustainabilityCA Prop 65
Flammability / Reaction to FireUL 1685 UL Loading, IEEE 1202 FT4, FT4
NEC / UL ComplianceArticle 336, TC-ER, XHHW-2
ICEA ComplianceS-95-658
European Directive ComplianceEU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE)
APAC ComplianceChina RoHS II (GB/T 26572-2011)
Other Standard Compliance(s)P-07-KA070003-MSHA