Belden Store
29527

Product Number: 29527

VFD, 3C #2 Str TC XLPE Ins + #10 Symm. Seg. Gnd (3 of #10) Str BC, CTS, Blk PVC Jkt, 600/1000V TC-ER 90C Dry/Wet 1000V CSA AWM I/II A/B

Belden Premium VFD, 2 AWG (7 x 19 x 23) Tinned Copper, 3 Conductor, XLPE Insulation M4 Color Code, With 3 #10 AWG (105 x 30) Bare Copper Ground Wire in Continuous Contact with Overall Dual Copper Tape Helically Applied Shield, Black Outer PVC Jacket, 600/1000V TC-ER 90C Dry/Wet 1000V, CSA AWM I/II A/B Sun Res Dir Bur Oil Res.

Availability
Global
Status
Active

Ships from and sold by A5 IT.

Specifications

Product Overview

Suitable ApplicationsVariable Frequency Drives (VFD); AC Motor and Drive Systems; Class 1 Division 2 Hazardous Locations; Recommended Cable Gland Belden BTC125A1271RA

Construction Details

Overall Cable Diameter (Nominal)1.09 in (27.7 mm)

Conductor

ElementNo. of ElementsSizeStrandingMaterialNotes
Conductor(s)32 AWG7x19x23TC - Tinned CopperASTM B3 Copper B8 Class B Stranding
Segmented Ground Wire310 AWG105x30TC - Tinned CopperSegmented Ground (3 Totaling 5 AWG)

Insulation

ElementMaterialNom. ThicknessNom. Insulation DiameterColor Code
Conductor(s)XLP, XLPO, XLPE (Thermoset)0.047 in (1.2 mm)0.424 in (10.8 mm)ICEA Chart M4
Ground WireNo Insulation

Outer Shield

Shield TypeMaterialCoverageNotes
TapeBare Copper (BC)100%2 Mil Copper Tape
Bare Copper (BC)

Outer Jacket

MaterialPVC - Polyvinyl Chloride
Nom. Thickness0.083 in (2.1 mm)
Nom. Diameter1.090 in (27.69 mm)
RipcordYes

Electrical Characteristics

Electricals

ElementNom. Conductor DCRNom. Capacitance Cond-to-CondNom. Capacitance Cond-to-Other (Conds + Shield)Nom. Characteristic ImpedenceNom. Velocity of Prop.Max. Current
Conductor(s)0.14 Ohm/1000ft (0.46 Ohm/km)35 pF/ft (110 pF/m)68 pF/ft (220 pF/m)44 Ohm55%130 Amps per Conductor at 30oC
0.03 Ohm/1000ft (0.098 Ohm/km)

Voltage

UL Voltage Rating600/1000 V (TC-ER)

Mechanical Characteristics

Max. Pull Tension2851 lbs (1293 kg)
Bulk Cable Weight969 lbs (440 kg)

Temperature

UL Temperature90°C Dry, 90°C Wet
Operating-20°C To +90°C

Bend Radius

Stationary Min.10.9 in (277 mm)
Installation Min.10.9 in (277 mm)

Standards and Compliance

Environmental SuitabilityIndoor, Outdoor, Sunlight Resistance, Burial
SustainabilityCA Prop 65
Flammability / Reaction to FireUL 1685 UL Loading, IEEE 1202 FT4, FT4
NEC / UL ComplianceArticle 336, TC-ER, XHHW-2
ICEA ComplianceS-95-658
European Directive ComplianceEU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE)
APAC ComplianceChina RoHS II (GB/T 26572-2011)
Other Standard Compliance(s)P-07-KA070003-MSHA

History

Update and RevisionRevision Number: 0.35 Revision Date: 03-05-2026

Resources

Related vfd cable