Belden Store
29524

Product Number: 29524

VFD, 3C #8 Str TC XLPE Ins + #14 Symm. Seg. Gnd (3 of #14) Str BC, CTS, Blk PVC Jkt, 600/1000V TC-ER 90C Dry/Wet 1000V CSA AWM I/II A/B

Belden Premium VFD, 8 AWG (7 x 19 x 29) Tinned Copper, 3 Conductor, XLPE Insulation M4 Color Code, With 3 #14 AWG (41 x 30) Bare Copper Ground Wire in Continuous Contact with Overall Copper Tape Helically Applied Shield, Black Outer PVC Jacket, 600/1000V TC-ER 90C Dry/Wet 1000V, CSA AWM I/II A/B Sun Res Dir Bur Oil Resistant.

Availability
Global
Status
Active

Ships from and sold by A5 IT.

Specifications

Product Overview

Suitable ApplicationsVariable Frequency Drives (VFD); AC Motor and Drive Systems; Class 1 Division 2 Hazardous Locations; Recommended Cable Gland Belden BTC100A0791RA

Construction Details

Overall Cable Diameter (Nominal)0.697 in (17.7 mm)

Conductor

ElementSizeStrandingMaterialNotes
Conductor(s)8 AWG7x19x29TC - Tinned CopperASTM B3 Copper B8 Class B Stranding
Segmented Ground Wire14 AWG41x30BC - Bare CopperSegmented Ground (3 Totaling 10+ AWG)

Insulation

ElementMaterialNom. ThicknessNom. Insulation DiameterColor Code
Conductor(s)XLPE - Cross-Linked Polyethylene (Thermoset)0.47 in0.26 in (6.6 mm)ICEA Chart M4
Ground WireNo Insulation

Outer Shield

Shield TypeMaterialCoverageNotes
TapeBare Copper (BC)100%2 mil Copper Tape
Bare Copper (BC)

Outer Jacket

MaterialXLPE - Cross-Linked Polyethylene (Thermoset)
Nom. Thickness0.063 in mm
Nom. Diameter0.697 in (17.7 mm)
RipcordYes

Electrical Characteristics

Electricals

ElementNom. Conductor DCRNom. Capacitance Cond-to-CondNom. Capacitance Cond-to-Other (Conds + Shield)Nom. Characteristic ImpedenceNom. Velocity of Prop.Max. Current
Conductor(s)0.564 Ohm/1000ft (1.85 Ohm/km)31 pF/ft (100 pF/m)63 pF/ft (210 pF/m)50 Ohm55%55 Amps per Conductor at 30oC
0.90 Ohm/1000ft (3.0 Ohm/km)

Voltage

UL Voltage Rating600/1000 V (TC-ER)

Mechanical Characteristics

Max. Pull Tension678 lbs (308 kg)
Bulk Cable Weight350 lbs/1000ft (520 kg/km)

Temperature

UL Temperature90°C Dry, 90°C Wet
Operating-20°C To +90°C

Bend Radius

Stationary Min.5.23 in (133 mm)
Installation Min.5.23 in

Standards and Compliance

Environmental SuitabilityIndoor, Outdoor, Sunlight Resistance, Burial
SustainabilityCA Prop 65
Flammability / Reaction to FireUL 1685 UL Loading, IEEE 1202 FT4
NEC / UL ComplianceArticle 336, TC-ER, XHHW-2
ICEA ComplianceS-95-658
European Directive ComplianceEU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE)
APAC ComplianceChina RoHS II (GB/T 26572-2011)
Other Standard Compliance(s)P-07-KA070003-MSHA

History

Update and RevisionRevision Number: 0.50 Revision Date: 04-02-2026

Resources

Related vfd cable