29522C

Product Number: 29522C

VFD, 3C #12 Str BC XLPE Ins + #12 Symm. Seg. Gnd (3 of #16) Str BC, CTS, Blk PVC Jkt, 600/1000V TC-ER 90C Dry/Wet 1000V

Belden Basics VFD, 3 Conductor 12AWG (7x20) Bare Copper XLPE Insulation M4 Color Code + 12AWG Symmetrical Segmented Ground (3 of 16AWG) Bare Copper Stranded in Continuous Contact with Overall Dual Copper Tape Helically Applied Shield, Black PVC Outer Jacket, 600/1000V TC-ER 90C Dry/Wet 1000V SUN RES DIR BUR Oil Resistant

Availability
Global
Status
Active
Orderable items
1

Ships from and sold by A5 IT.

Part numbers

29522C is a product family. Each item number below is a separate orderable part — colour, put-up and length differ.

Item #ColorPutup TypeLengthUPCOrder
29522C 0105000BlackReel5,000 ft612825137689Order online

Specifications

Information

Put-Up TypeReel
Update and RevisionRevision Number: 0.702 Revision Date: 04-01-2026

Product Overview

Suitable ApplicationsVariable Frequency Drives (VFD); AC Motor and Drive Systems; Class 1 Division 2 Hazardous Locations; Recommended Cable Gland Belden BTC075A0551RA

Construction Details

Overall Cable Diameter (Nominal)0.460 in (11.7 mm)

Conductor

ElementNo. of ElementsSizeStrandingMaterialNotes
Conductor(s)312 AWG7x20BC - Bare CopperASTM B3 Copper B8 Class B Stranding
Segmented Ground Wire316 AWG7x24BC - Bare Copper3 Ground Segments totaling 12 AWG

Insulation

ElementMaterialNom. ThicknessNom. Insulation DiameterColor Code
Conductor(s)XLPE - Cross-Linked Polyethylene (Thermoset)0.030 in (0.76 mm)0.153 in (3.89 mm)ICEA Chart M4
Ground WireNo Insulation

Outer Shield

Shield TypeMaterialCoverage
Helical TapeBare Copper (BC)100%
Helical TapeBare Copper (BC)100%

Outer Jacket

MaterialPVC - Polyvinyl Chloride
Nom. Thickness0.060 in (1.5 mm)
Nom. Diameter0.460 in (11.7 mm)
RipcordYes

Electrical Characteristics

Nom Outer Shield DCR0.97 Ohm/1000ft (3.2 Ohm/km)

Electricals

ElementNom. Conductor DCRNom. Capacitance Cond-to-CondNom. Capacitance Cond-to-Other (Conds + Shield)Nom. Characteristic ImpedenceNom. Velocity of Prop.Max. Current
Conductor(s)1.423 Ohm/1000ft (4.669 Ohm/km)29 pF/ft (95 pF/m)56 pF/ft (180 pF/m)50 Ohm55%30 Amps per Conductor at 30oC
1.5 Ohm/1000ft (4.9 Ohm/km)

Voltage

UL Voltage Rating600 / 1000 V (TC-ER)

Mechanical Characteristics

Max. Pull Tension283 lbs (128 kg)
Bulk Cable Weight191 lbs/1000ft (284 kg/km)

Temperature

UL Temperature90°C Dry, 90°C Wet
Operating-40°C To +90°C

Bend Radius

Stationary Min.5.5 in (140 mm)
Installation Min.5.5 in (140 mm)

Standards and Compliance

Environmental SuitabilityIndoor, Outdoor, Sunlight Resistance, Burial
SustainabilityCA Prop 65
Flammability / Reaction to FireUL 1685 UL Loading, IEEE 1202 FT4
NEC / UL ComplianceArticle 336, TC-ER
ICEA ComplianceS-95-658
European Directive ComplianceEU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE)
APAC ComplianceChina RoHS II (GB/T 26572-2011)
Other Standard Compliance(s)P-07-KA070003-MSHA