Belden Store
29522

Product Number: 29522

VFD, 3C #12 Str TC XLPE Ins + #12 Symm. Seg. Gnd (3 of #16) Str TC, OS +TC Brd, Blk PVC Jkt, 600/1000V TC-ER 90C Dry/Wet 1000V CSA AWM I/II A/B

Belden Premium VFD, 12 AWG (65 x 30) Tinned Copper, 3 Conductor, XLPE Insulation M4 Color Code, Duofoil Beldfoil Shield With 3 #16 AWG (65 x 34) Tinned Copper Ground Wire in Continuous Contact with Overall Beldfoil® (100%) + Tinned Copper Braid Coverage (85%), Black Outer PVC Jacket, 600/1000V TC-ER 90C Dry/Wet 1000V, CSA AWM I/II A/B Sun Res Dir Bur Oil Resistant.

Availability
Global
Status
Active

Ships from and sold by A5 IT.

Specifications

Product Overview

Suitable ApplicationsVariable Frequency Drives (VFD); AC Motor and Drive Systems; Class 1 Division 2 Hazardous Locations; Recommended Cable Gland Belden BTC075A0551RA

Construction Details

Overall Cable Diameter (Nominal)0.485 in (12.3 mm)

Conductor

ElementNo. of ElementsSizeStrandingMaterialNotes
Conductor(s)312 AWG65x30TC - Tinned CopperASTM B3 Copper B8 Class B Stranding
Segmented Ground Wire316 AWG65x34TC - Tinned Copper3 Ground Segments Totaling 12 AWG

Insulation

ElementMaterialNom. ThicknessNom. Insulation DiameterColor Code
Conductor(s)XLPE - Cross-Linked Polyethylene (Thermoset)0.030 in (0.76 mm)0.163 in (4.14 mm)ICEA Chart M4
Ground WireNo Insulation

Outer Shield

Shield TypeMaterialCoverageDrainwire Type
TapeTinned Copper (TC)100%16 AWG (65x34) TC
BraidTinned Copper (TC)85%

Outer Jacket

MaterialXLPE - Cross-Linked Polyethylene (Thermoset)
Nom. Thickness0.047 in (1.2 mm)
Nom. Diameter0.458 in (11.6 mm)

Electrical Characteristics

Electricals

ElementNom. Conductor DCRNom. Capacitance Cond-to-CondNom. Capacitance Cond-to-Other (Conds + Shield)Nom. Characteristic ImpedenceNom. Velocity of Prop.Max. Current
Conductor(s)1.423 Ohm/1000ft (4.669 Ohm/km)29 pF/ft (95 pF/m)56 pF/ft (180 pF/m)50 Ohm55%30 Amps per Conductor at 30C
1.5 Ohm/1000ft (4.9 Ohm/km)

Voltage

UL Voltage Rating600/1000 V (TC-ER)

Mechanical Characteristics

Max. Pull Tension283 lbs (128 kg)
Bulk Cable Weight182 lbs/1000ft (271 kg/km)

Temperature

UL Temperature90°C Dry, 90°C Wet
Operating-20°C To +90°C

Bend Radius

Stationary Min.3.435 in (87.25 mm)
Installation Min.3.435 in (87.25 mm)

Standards and Compliance

Environmental SuitabilityIndoor, Outdoor, Sunlight Resistance, Burial
SustainabilityCA Prop 65
Flammability / Reaction to FireUL 1685 UL Loading, IEEE 1202 FT4
NEC / UL ComplianceArticle 336, TC-ER
ICEA ComplianceS-95-658
European Directive ComplianceEU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE)
APAC ComplianceChina RoHS II (GB/T 26572-2011)
Other Standard Compliance(s)P-07-KA070003-MSHA

History

Update and RevisionRevision Number: 0.51 Revision Date: 04-02-2026

Resources