Belden Store
29521C

Product Number: 29521C

VFD, 3C #14 Str BC XLPE Ins + #14 Symm. Seg. Gnd (3 of #18) Str BC, CTS, Blk PVC Jkt, 600/1000V TC-ER 90C Dry/Wet 1000V

Belden Basics VFD, 3 Conductor 14AWG (7x22) Bare Copper XLPE Insulation M4 Color Code + 14AWG Symmetrical Segmented Ground (3 of 18AWG) Bare Copper Stranded, Overall Dual Copper Tape Helically Applied Shield, Black PVC Outer Jacket, 600/1000V TC-ER 90C Dry/Wet 1000V SUN RES DIR BUR Oil Resistant

Availability
Global
Status
Active
Orderable items
2

Ships from and sold by A5 IT.

Part numbers

29521C is a product family. Each item number below is a separate orderable part — colour, put-up and length differ.

Item #ColorPutup TypeLengthUPCOrder
29521C 0101000BlackReel1,000 ft612825137641Order online
29521C 0105000BlackReel5,000 ft612825137658Order online

Specifications

Information

Put-Up TypeReel
Update and RevisionRevision Number: 0.745 Revision Date: 04-01-2026

Product Overview

Suitable ApplicationsVariable Frequency Drives (VFD); AC Motor and Drive Systems; Class 1 Division 2 Hazardous Locations; Recommended Cable Gland Belden BTC075A0551RA

Construction Details

Overall Cable Diameter (Nominal)0.425 in (10.8 mm)

Conductor

ElementNo. of ElementsSizeStrandingMaterialNotes
Conductor(s)314 AWG7x22BC - Bare CopperASTM B3 Copper B8 Class B Stranding
Ground Wire318 AWG7x26BC - Bare CopperSegmented Ground 14AWG Total + Copper Tape

Insulation

ElementMaterialNom. ThicknessNom. Insulation DiameterColor Code
Conductor(s)XLPE - Cross-Linked Polyethylene (Thermoset)0.030 in (0.76 mm)0.131 in (3.33 mm)ICEA Chart M4
Ground WireNo Insulation

Outer Shield

Shield TypeMaterialCoverage
Helical TapeBare Copper (BC)100%
Helical TapeBare Copper (BC)100%

Outer Jacket

MaterialPVC - Polyvinyl Chloride
Nom. Thickness0.060 in (1.5 mm)
Nom. Diameter0.425 in (10.8 mm)
RipcordYes

Electrical Characteristics

Nom Outer Shield DCR1.60 Ohm/1000ft (5.25 Ohm/km)

Electricals

ElementNom. Conductor DCRNom. Capacitance Cond-to-CondNom. Capacitance Cond-to-Other (Conds + Shield)Nom. Characteristic ImpedenceNom. Velocity of Prop.Max. Current
Conductor(s)2.282 Ohm/1000ft (7.487 Ohm/km)23 pF/ft (75 pF/m)42 pF/ft (140 pF/m)80 Ohm55%25 Amps per Conductor at 30oC
Ground1.9 Ohm/1000ft (6.2 Ohm/km)

Voltage

UL Voltage Rating600 / 1000 V (TC-ER)

Mechanical Characteristics

Max. Pull Tension186 lbs (84.4 kg)
Bulk Cable Weight134 lbs/1000ft (199 kg/km)

Temperature

UL Temperature90°C Dry, 90°C Wet
Operating-40°C To +90°C

Bend Radius

Stationary Min.5.1 in (130 mm)
Installation Min.5.1 in (130 mm)

Standards and Compliance

Environmental SuitabilityIndoor, Outdoor, Sunlight Resistance, Burial
SustainabilityCA Prop 65
Flammability / Reaction to FireUL 1685 UL Loading, IEEE 1202 FT4
NEC / UL ComplianceArticle 336, TC-ER, XHHW-2
ICEA ComplianceS-95-658
European Directive ComplianceEU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE)
APAC ComplianceChina RoHS II (GB/T 26572-2011)
Other Standard Compliance(s)P-07-KA060003-MSHA