VFD 300% Gnd, 3C+G #4 Str TC, XLPE Ins+PVC Gnd, OS+TC Brd w/4-#10 TC Drains, Blk PVC Jkt, 600/1000V TC-ER 90C Dry/Wet 1000V Flexible Motor Supply Cable WTTC
Belden 300% Ground Flexible VFD, 3 Conductor 4AWG (7x19x25) Tinned Copper, XLPE Insulation M4 Color Code+PVC Insulated Ground, Overall Beldfoil®+Tinned Copper Braid(85%) Shield w/4-10AWG Tinned Copper Ground/Drains, Black PVC Outer Jacket, 600/1000V TC-ER 90C Dry/Wet 1000V Flexible Motor Supply Cable WTTC 1000V CSA AWM I/II A/B 600V CIC TC SUN RES DIR BUR Oil Resistant
- Availability
- Global
- Status
- Active
- Orderable items
- 3
Part numbers
29506 is a product family. Each item number below is a separate orderable part — colour, put-up and length differ.
| Item # | Color | Putup Type | Length | UPC | Footnote | Order |
|---|---|---|---|---|---|---|
| 29506 010250 | Black | Reel | 250 ft | 612825137245 | C Z | Order online |
| 29506 0101000 | Black | Reel | 1,000 ft | 612825137238 | C Z | Order online |
| 29506 0103000 | Black | Reel | 3,000 ft | 612825137269 | C Z | Order online |
Specifications
Information
| Put-Up Type | Reel |
|---|---|
| Update and Revision | Revision Number: 0.736 Revision Date: 06-30-2026 |
| Footnote | C - CRATE REEL PUT-UP., Z - FINAL PUT-UP MAY VARY (= OR -) 10% FOR SPOOLS OR REELS AND (+ OR -) 5% FOR UNREEL CARTONS FROM LENGTH SHOWN. |
Product Overview
| Suitable Applications | Variable Frequency Drives (VFD); AC Motor and Drive Systems; Class 1 Division 2 Hazardous Locations; Recommended Cable Gland Belden BTC125A1271RA |
|---|
Construction Details
| Overall Cable Diameter (Nominal) | 1.113 in (28.27 mm) |
|---|
Conductor
| Element | No. of Elements | Size | Stranding | Material | Notes |
|---|---|---|---|---|---|
| Conductor(s) | 3 | 4 AWG | 7x19x25 | TC - Tinned Copper | |
| Insulated Ground | 1 | 4 AWG | 7x19x25 | TC - Tinned Copper | Insulated Ground Wire |
| Uninsulated Ground Wire | 4 | 10 AWG | 105x30 | TC - Tinned Copper | Segmented Ground Wire (4 Totaling 4 AWG) |
Insulation
| Element | Material | Nom. Thickness | Nom. Insulation Diameter | Color Code | Notes |
|---|---|---|---|---|---|
| Conductor(s) | XLPE - Cross-Linked Polyethylene (Thermoset) | 0.062 in (1.6 mm) | 0.367 in (9.32 mm) | ICEA Chart M4 | |
| Ground Wire | PVC - Polyvinyl Chloride | 0.062 in (1.6 mm) | 0.367 in (9.32 mm) | Green/Yellow Stripe | |
| Uninsulated Ground Wire | Segmented Ground (4 Totaling 4 AWG) |
Outer Shield
| Shield Type | Material | Coverage | Drainwire Type |
|---|---|---|---|
| Tape | Tri-Laminate (Alum+Poly+Alum) | 100% | 10 AWG (105x30) TC |
| Braid | Tinned Copper (TC) | 86% |
Outer Jacket
| Material | PVC - Polyvinyl Chloride |
|---|---|
| Nom. Thickness | 0.093 in (2.4 mm) |
| Nom. Diameter | 1.113 in (28.27 mm) |
| Ripcord | Yes |
Electrical Characteristics
| Nom Outer Shield DCR | 0.21 Ohm/1000ft (0.69 Ohm/km) |
|---|
Electricals
| Element | Nom. Conductor DCR | Nom. Capacitance Cond-to-Cond | Nom. Capacitance Cond-to-Other (Conds + Shield) | Nom. Characteristic Impedence | Nom. Inductance Cond-Grnd | Nom. Velocity of Prop. | Max. Current |
|---|---|---|---|---|---|---|---|
| Conductor(s) | 0.239 Ohm/1000ft (0.784 Ohm/km) | 32 pF/ft (100 pF/m) | 60 pF/m (18 pF/ft) | 37 Ohm | 0.12 μH/ft | 55% | 95 Amps per Conductor at 30oC |
| Insulated Ground | 0.2689 Ohm/1000ft (0.8822 Ohm/km) | ||||||
| Uninsulated Ground Wire | 0.2689 Ohm/1000ft (0.8822 Ohm/km) |
Voltage
| UL Voltage Rating | 1000 V (TC-ER, WTTC, UL44, UL Flexible Motor Supply Cable), 600 V (C(UL) CIC TC) |
|---|---|
| Voltage Rating | 1000 V (AWM I/II A/B) |
Mechanical Characteristics
| Max. Pull Tension | 2420 lbs (1100 kg) |
|---|---|
| Bulk Cable Weight | 1061 lbs/1000ft (1579 kg/km) |
Temperature
| UL Temperature | 90°C Dry, 90°C Wet |
|---|---|
| Operating | -40°C To +90°C |
Bend Radius
| Stationary Min. | 11.3 in (287 mm) |
|---|---|
| Installation Min. | 13.4 in (340 mm) |
Standards and Compliance
| Environmental Suitability | Indoor, Outdoor, Sunlight Resistance, Burial |
|---|---|
| Sustainability | CA Prop 65 |
| Flammability / Reaction to Fire | UL 1685 UL Loading, FT4, IEEE 1202 FT4 |
| NEC / UL Compliance | Article 336, TC-ER, WTTC, UL Flexible Motor Supply Cable |
| AWM Compliance | AWM I/II A/B |
| CEC / C(UL) Compliance | CIC, TC. |
| ICEA Compliance | S-95-658 |
| European Directive Compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| APAC Compliance | China RoHS II (GB/T 26572-2011) |
| Other Standard Compliance(s) | P-07-KA070003-MSHA |
History
| Update and Revision | Revision Number: 0.736 Revision Date: 06-30-2026 |
|---|---|
| Footnote | C - CRATE REEL PUT-UP., Z - FINAL PUT-UP MAY VARY (= OR -) 10% FOR SPOOLS OR REELS AND (+ OR -) 5% FOR UNREEL CARTONS FROM LENGTH SHOWN. |
Resources
Related vfd cable

29500
VFD 300% Gnd, 3C+G #16 Str TC, XLPE Ins+PVC Gnd, OS+TC Brd w/#16 TC Ground/Drain, Blk PVC Jkt, 600V TC-ER 90C Dry/Wet 1000V Flexible Motor Supply Cable WTTC
PVC - Polyvinyl Chloride · 600 V RMS (Type TC) (TC-ER, WTTC, UL Flexible Motor Supply Cable), 600 V (C(UL) CIC TC) · 90°C Dry, 90°C Wet

29500T
VFD 300% Gnd, 3C+G #16 Str TC, XLPE Ins+PVC Grd, OS+TC Brd w/#16 TC Drain, Blk LSZH Jkt, 600V TC-ER 90C Dry/Wet 1000V Flexible Motor Supply Cable WTTC
LSZH - Low Smoke Zero Halogen (Flame Retardant) · 1000 V (TC, WTTC, UL Flexible Motor Supply Cable) · 90°C Dry, 90°C Wet

29501
VFD 300% Gnd, 3C+G #14 Str TC, XLPE Ins+PVC Gnd, OS+TC Brd w/#14 TC Ground/Drain, Blk PVC Jkt, 600/1000V TC-ER 90C Dry/Wet 1000V Flexible Motor Supply Cable WTTC
PVC - Polyvinyl Chloride · 1000 V (TC-ER, WTTC,UL44, UL Flexible Motor Supply Cable), 600 V (C(UL) CIC TC) · 90°C Dry, 90°C Wet

29501T
VFD 300% Gnd, 3C+G #14 Str TC, XLPE Ins+PVC Grd, OS+TC Brd w/#14 TC Drain, Blk LSZH Jkt, 600/1000V TC-ER 90C Dry/Wet 1000V Flexible Motor Supply Cable WTTC
LSZH - Low Smoke Zero Halogen (Flame Retardant) · 1000 V (TC, WTTC, UL Flexible Motor Supply Cable) · 90°C Dry, 90°C Wet