Indoor Digital Electricity Copper Cable, #16-4pr, TC, LS-PVC, CL4P, CMP, LS-PVC Jkt
Indoor Digital Electricity Copper Cable, 4-16 AWG Stranded (19x29) Tinned Copper Pairs with Flamarrest® insulation, Plenum-CL4P, CMP, Flamarrest® Jacket with Ripcord
- Availability
- Global
- Status
- Active
- Orderable items
- 1
Part numbers
DEIP164U is a product family. Each item number below is a separate orderable part — colour, put-up and length differ.
| Item # | Color | Length | Order |
|---|---|---|---|
| DEIP164U | Apple Green | 2,000 ft | Order online |
Specifications
Product Overview
| Suitable Applications | Digital ElectricityTM, Fault Managed Power Systems (FMPS), remote powering, indoor |
|---|
Construction Details
Conductor
| Size | 16 |
|---|---|
| Stranding | 19x29 |
| Material | TC - Tinned Copper |
Insulation
| Material | PVC - Polyvinyl Chloride |
|---|---|
| Nom. Thickness | 0.011 in (0.28 mm) |
| Color Code | Black & Red, Black & White, Black & Green, Black & Blue |
Outer Jacket
| Material | PVC - Polyvinyl Chloride |
|---|---|
| Nom. Thickness | 0.017 in (0.43 mm) |
| Nom. Diameter | 0.386 in (9.80 mm) |
Electrical Characteristics
Electricals
| Nom. Conductor DCR | 4.3 Ohm/1000ft |
|---|---|
| Nom. Capacitance Cond-to-Cond | 30 pF/ft (98 pF/m) |
| Max. Current | 7.5 Amps per Conductor at 25oC (35°C Temperature Rise) |
Voltage
| UL Voltage Rating | 450 V RMS |
|---|
Mechanical Characteristics
| Max. Pull Tension | 243 lbs (110 kg) |
|---|---|
| Bulk Cable Weight | 95 lbs/1000ft |
Temperature
| UL Temperature | 75°C |
|---|---|
| Operating | 0°C To +75°C |
Standards and Compliance
| Environmental Suitability | Indoor |
|---|---|
| Flammability / Reaction to Fire | NFPA 262, FT6 |
| NEC / UL Compliance | Article 800, CL4P, CL3P |
| CEC / C(UL) Compliance | CMP. |
| European Directive Compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE), REACH: 2019-05-14 |
| APAC Compliance | China RoHS II (GB/T 26572-2011) |
History
| Update and Revision | Revision Number: 0.77 Revision Date: 09-07-2025 |
|---|
Resources
Related fault-managed power system (fmps) cables

DEDN142F
Indoor/Outdoor Digital ElectricityTM, 2 Pr #14 Str TC, O/A Foil, PVC Jkt, CL4, CL3, Wet Locations
14 · TC - Tinned Copper · PVC - Polyvinyl Chloride

DEDN142U
Indoor/Outdoor Digital ElectricityTM, 2 Pr #14 Str TC, PVC Jkt, CL4, CL3, Wet Locations
14 · TC - Tinned Copper · PVC - Polyvinyl Chloride

DEDN144F
Indoor/Outdoor Digital ElectricityTM, 4 Pr #14 Str TC, O/A Foil, PVC Jkt, CL4, CL3, Wet Locations
14 · TC - Tinned Copper · PVC - Polyvinyl Chloride

DEDN144U
Indoor/Outdoor Digital ElectricityTM, 4 Pr #14 Str TC, PVC Jkt, CL4, CL3, Wet Locations
14 · TC - Tinned Copper · PVC - Polyvinyl Chloride