Belden Store
BeldenHF25G0.75

Product Number: HF25G0.75

MachFlexTM High Flex 350YY, 24+1G C 0.75mm2 Str BC, PVC Ins, PVC Jkt

MachFlexTM High Flex Control 350YY, 24 Conductor + 1 Ground 0.75mm2 Stranded Bare Copper, PVC Insulation, PVC Jacket

Availability
Global
Status
Active

Ships from and sold by A5 IT.

Specifications

Product Overview

Suitable ApplicationsApplicable for high flexible (up to 5 million flex cycles) installation connecting precision control sensors, multi axis control machines, temperature controllers, control panels, machine cutting tools, auxiliary equipment, motor speed control, production machinery and many more.

Construction Details

Overall Cable Diameter (Nominal)15.4 mm (0.606 in)

Conductor

ElementNo. of ElementsSizeStrandingStranding ClassMaterial
Conductor(s)240.75 mm2StrandedClass 6BC - Bare Copper
Ground10.75 mm2StrandedClass 6BC - Bare Copper

Insulation

ElementMaterialColor Code
Conductor(s)PVC - Polyvinyl ChlorideBlack #1, Black #2, Black #3, Black #4, Black #5, Black #6, Black #7, Black #8, Black #9, Black #10, Black #11, Black #12, Black #13, Black #14, Black #15, Black #16, Black #17, Black #18, Black #19, Black #20, Black #21, Black #22, Black #23, Black #24
GroundPVC - Polyvinyl ChlorideYellow/Green

Outer Jacket

MaterialPVC - Polyvinyl Chloride

Electrical Characteristics

Voltage

Voltage Rating300/500 V (Max. Operating Voltage)

Mechanical Characteristics

Bend Radius Table NotesDrag Chain Performance : 1m Travel Distance, Travel Speed 2m/s, Acceleration 4m/s2 ≥ 5,000,000 Cycles; 3m Travel Distance, Travel Speed 3m/s, Acceleration 10m/s2 ≥ 1,000,000 Cycles; 5m Travel Distance, Travel Speed 3m/s, Acceleration 10m/s2 ≥ 200,000 Cycles
Bulk Cable Weight357 kg/km (240 lbs/1000ft)

Temperature

Installation-40°C to +80°C(Fixed installation)
Continuous Flexing0°C to +70°C

Bend Radius

Installation Min.61.6 mm (2.43 in)
Flexing Min.115.5 mm (4.547 in)

Standards and Compliance

Environmental SuitabilityIndoor, Outdoor, Sunlight Resistance, UV Resistance, Oil Resistance - EN 50290-2-22 (TM54), Oil Resistance
Flammability / Reaction to FireIEC 60332-1-2, DIN VDE 0482-332-1-2, DIN EN 60332-1-2
Third Party Performance VerificationVDE Certification No. 40051701, VDE Registration No. F743
European Directive ComplianceEU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2)
APAC ComplianceChina RoHS II (GB/T 26572-2011)
Other Standard Compliance(s)VDE 0285-525-2-11, VDE 0285-525-2-51

History

Update and RevisionRevision Number: 0.32 Revision Date: 07-15-2024

Resources

Related flex cable