MachFlexTM 610HH, 19+1G C 2.5mm2 Str BC, LSZH Ins, LSZH Jkt, UL AWM Style 21115
MachFlexTM 610HH, 19 Conductor + 1 Ground 2.5mm2 Stranded Bare Copper, LSZH Insulation, LSZH Jacket , UL AWM Style 21115
- Availability
- Global
- Status
- Active
Specifications
Product Overview
| Suitable Applications | Designed for applications which are installed in occasional flexing and fixed locations. Cable applications include precision control sensors, multi axis control machines, temperature controllers, control panels, machine cutting tools, auxiliary equipment, motor speed control, production machinery and many more. Utilizing LSZH material emits limited smoke and no halogen when exposed to high sources of heat. It can considerably reduce the amount and density of the smoke, toxic and corrosive gas emitted during a fire, enable easier evacuation as well as safer firefighting operations. |
|---|
Construction Details
Conductor
| Element | Size | Stranding | Material |
|---|---|---|---|
| Conductor(s) | 2.5 mm2 | Class 5 | BC - Bare Copper |
| Ground | 2.5 mm2 | Class 5 | BC - Bare Copper |
Insulation
| Material | LSZH - Low Smoke Zero Halogen (Flame Retardant) |
|---|---|
| Color Code | Black #1, Black #2, Black #3, Black #4, Black #5, ..., Black #19, Green/Yellow |
Outer Jacket
| Material | LSZH - Low Smoke Zero Halogen (Flame Retardant) |
|---|---|
| Nom. Diameter | 21.63mm |
Electrical Characteristics
Electricals
| Max. Conductor DCR | 7.98 Ohm/km (2.43 Ohm/1000ft) |
|---|
Voltage
| Voltage Rating | 600/1000 V (IEC:) |
|---|
Mechanical Characteristics
| Bulk Cable Weight | 802 kg/km (539 lbs/1000ft) |
|---|
Temperature
| Operating | -25°C to +70°C |
|---|---|
| Installation | -40°C to +80°C |
Bend Radius
| Installation Min. | 4 x OD |
|---|
Standards and Compliance
| Environmental Suitability | Indoor, Outdoor, Sunlight Resistance, UV Resistance, Oil Resistance, Oil Resistance |
|---|---|
| Flammability / Reaction to Fire | IEC 60332-1-2, IEC 60332-3-24, IEC 60332-3-25, DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-3-24, IEC 60332-3-25 |
| AWM Compliance | AWM 21115 |
| European Halogen Free Standards | IEC 60754-2 - Halogen Acid Gas Amount - Max. Conductivity = 10 μS/mm, IEC 60754-2 - Halogen Acid Gas Amount - Min. pH = 4.3, IEC 61034-2 - Smoke Density Min. Transmittance = 60 |
| European Directive Compliance | EU Directive 2011/65/EU (RoHS 2) |
| Other Standard Compliance(s) | EN 50525-3-11 |
History
| Update and Revision | Revision Number: 0.19 Revision Date: 07-05-2024 |
|---|
Resources
Related flex cable

10C0.14HH
MachFlexTM LiHH, 10 C 0.14mm2 Str BC, PE Ins, LSZH Jkt
10 · 0.14 mm2 · BC - Bare Copper · PE - Polyethylene
9 items

10C0.14YCY
MachFlexTM LiYCY, 10 C 0.14mm2 Str BC, PVC Ins, TCBS, PVC Jkt
10 · 0.14 mm2 · BC - Bare Copper · PVC - Polyvinyl Chloride
9 items

10C0.14YY
MachFlexTM LiYY, 10 C 0.14mm2 Str BC, PVC Ins, PVC Jkt
10 · 0.14 mm2 · BC - Bare Copper · PVC - Polyvinyl Chloride
9 items

10C0.25HCH
MachFlexTM LiHCH, 10 C 0.25mm2 Str BC, PE Ins, TCBS, LSZH Jkt
10 · 0.25 mm2 · BC - Bare Copper · PE - Polyethylene
9 items