
MachFlexTM 610HH, 17+1G C 2.5mm2 Str BC, LSZH Ins, LSZH Jkt, UL AWM Style 21115
MachFlexTM 610HH, 17 Conductor + 1 Ground 2.5mm2 Stranded Bare Copper, LSZH Insulation, LSZH Jacket , UL AWM Style 21115
- Availability
- Asia Pacific
- Status
- Active
Specifications
Product Overview
| Suitable Applications | Designed for applications which are installed in occasional flexing and fixed locations. Cable applications include precision control sensors, multi axis control machines, temperature controllers, control panels, machine cutting tools, auxiliary equipment, motor speed control, production machinery and many more. Utilizing LSZH material emits limited smoke and no halogen when exposed to high sources of heat. It can considerably reduce the amount and density of the smoke, toxic and corrosive gas emitted during a fire, enable easier evacuation as well as safer firefighting operations. |
|---|
Physical Characteristics (Overall)
| Conductor Count | 18 |
|---|
Conductor
| Element | AWG | Stranding | Material | No. of Conductors |
|---|---|---|---|---|
| Conductor(s) | 2.5 mm2 | Class 5 | BC - Bare Copper | 17 |
| Ground | 2.5 mm2 | Class 5 | BC - Bare Copper | 1 |
Insulation
| Material | LSZH - Low Smoke Zero Halogen (Flame Retardant) |
|---|
Color Chart
| Color |
|---|
| Black #1 |
| Black #2 |
| Black #3 |
| Black #4 |
| Black #5 |
| ... |
| Black #17 |
| Green/Yellow |
Outer Jacket
| Material | LSZH - Low Smoke Zero Halogen (Flame Retardant) |
|---|---|
| Nominal Diameter | 20.45mm |
Electrical Characteristics
Conductor DCR
| Max. Conductor DCR | 7.98 Ohm/km |
|---|
Voltage
| Dielectric Withstand Voltage | 4000 V |
|---|---|
| Non-UL Description | IEC: |
| Non-UL Voltage Rating | 600/1000 V |
Temperature Range
| Installation Temperature Range | -40°C to +80°C |
|---|---|
| Operating Temperature Range | -25°C to +70°C |
Mechanical Characteristics
| Oil Resistance | Yes |
|---|---|
| UV Resistance | Yes |
| Bulk Cable Weight | 749 kg/km |
| Minimum Bend Radius During Installation | 4 x OD |
| Minimum Bend Radius During Operation | 15 x OD |
Standards
| UL AWM Style Compliance | AWM 21115 |
|---|
Applicable Environmental and Other Programs
| EU Directive 2011/65/EU (RoHS 2) | Yes |
|---|
Suitability
| Suitability - Indoor | Yes |
|---|---|
| Suitability - Oil Resistance | Yes |
| Suitability - Outdoor | Yes |
| Suitability - Sunlight Resistance | Yes |
Flammability, LS0H, Toxicity Testing
| IEC Flammability | IEC 60332-1-2, IEC 60332-3-24, IEC 60332-3-25 |
|---|---|
| Other Flammability | DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-3-24, IEC 60332-3-25 |
| IEC 60754-2 - Halogen Acid Gas Amount - Max. Conductivity | 10 μS/mm |
| IEC 60754-2 - Halogen Acid Gas Amount - Min. pH | 4.3 |
| IEC 61034-2 - Smoke Density Min. Transmittance | 60 |
History
| Update and Revision | Revision Number: 0.11 Revision Date: 11-09-2022 |
|---|
Resources
Related flex cable

10C0.14HH
MachFlexTM LiHH, 10 C 0.14mm2 Str BC, PE Ins, LSZH Jkt
10 · 0.14 mm2 · BC - Bare Copper · PE - Polyethylene
9 items

10C0.14YCY
MachFlexTM LiYCY, 10 C 0.14mm2 Str BC, PVC Ins, TCBS, PVC Jkt
10 · 0.14 mm2 · BC - Bare Copper · PVC - Polyvinyl Chloride
9 items

10C0.14YY
MachFlexTM LiYY, 10 C 0.14mm2 Str BC, PVC Ins, PVC Jkt
10 · 0.14 mm2 · BC - Bare Copper · PVC - Polyvinyl Chloride
9 items

10C0.25HCH
MachFlexTM LiHCH, 10 C 0.25mm2 Str BC, PE Ins, TCBS, LSZH Jkt
10 · 0.25 mm2 · BC - Bare Copper · PE - Polyethylene
9 items